Ruitao Yang

Prof. Dr. Ruitao Yang

School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin 150080, China
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2024 in Photonics Research
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
YDYisi Dong
Yisi Dong
PHPeng-Cheng Hu
Peng-Cheng Hu
HFHaijin Fu
Haijin Fu
HYHongxing Yang
Hongxing Yang
JTJiubin Tan
Jiubin Tan
The embedded ultra-precision displacement measurement is of great interest in developing high-end equipment as well as precision metrology. However, conventional interferometers only focus on measurement accuracy neglecting the sensor volume and requirement of embedded measurement, thus hindering their broad applications. Here we present a new sensing method for realizing large-range displacement measurement in narrow space scenarios based on the combination of a fiber microprobe interference-sensing model and precision phase-generated carrier. This is achieved by microprobe tilted-axis Gaussian optical field diffraction and high-order carrier demodulation to realize large-range displacement sensing. It is uncovered that the microprobe element misalignment and phase demodulation means play pivotal roles in the interference signal and the accuracy of large-range displacement sensing. The analysis shows that the proposed interference-sensing method can effectively reduce the nonlinearities. Experimental results illustrate that the measurement range extends from 0 to 700 mm. Furthermore, the maximum nonlinear error is reduced from tens of nanometers to 0.82 nm over the full range, allowing subnanometer accuracy for embedded measurements in the hundreds of millimeters range.

7 October 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Ruitao YangRuitao Yang
Ruitao Yang
FPFlorian Pollinger
Florian Pollinger
KMKarl Meiners-Hagen
Karl Meiners-Hagen
JTJiubin Tan
Jiubin Tan
HBHarald Bosse
Harald Bosse
We present a heterodyne absolute distance interferometer with a macroscopic range, based on a promising optical source. The basis of the heterodyne measurement principle, a frequency comb pair with slightly different repetition rates and offset frequencies, is realized coherently by synchronized cavity-enhanced electro-optic frequency comb generators. The unknown distance is determined absolutely from the interferometric phases of distinct comb modes, by a parallel digital lock-in scheme. Comparison experiments with a reference HeNe incremental interferometer show an agreement well within 15 μm, for a range up to 10 m.

1 July 2015 in Measurement Science and Technology
Verified
Journal Article
Closed access
Ruitao YangRuitao Yang
Ruitao Yang
FPFlorian Pollinger
Florian Pollinger
KMKarl Meiners-Hagen
Karl Meiners-Hagen
MKMichael Krystek
Michael Krystek
JTJiubin Tan
Jiubin Tan
HBHarald Bosse
Harald Bosse
We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

17 January 2020 in Optics Express
Verified
Journal Article
Closed access
YDYisi Dong
Yisi Dong
PHPeng-Cheng Hu
Peng-Cheng Hu
MRMing Ran
Ming Ran
HFHaijin Fu
Haijin Fu
HYHongxing Yang
Hongxing Yang
Ruitao YangRuitao Yang
Ruitao Yang
In fiber-optic interferometers with laser frequency modulation, carrier phase delay and accompanied optical intensity modulation (AOIM) in phase-generated-carrier (PGC) demodulation inevitably produce nonlinear errors that can seriously hamper displacement measurement accuracy. As for the existing improved PGC scheme, they are only capable to compensate for one of these effects. As the only method that is effective in eliminating the two effects simultaneously, typical ellipse fitting methods require target movements λlaser/4, and fail when the PGC carrier phase delay is proximate to certain values (e.g., nπ +π/4, nπ +π/2). Herein, a modified nonlinear-error correction method for errors due to PGC carrier phase delay and AOIM is proposed. Active laser-wavelength scanning by constant variation of the laser drive temperature is used to replace the target movement. A fiber-optic Michelson interferometer is constructed and experiments are performed to verify the feasibility of the proposed method. The experimental results show that after correction, the nonlinear error is reduced to less than 1nm, and nanoscale displacement measurement is achieved.

13 December 2021 in Photonics Research
Verified
Journal Article
Closed access
YDYisi Dong
Yisi Dong
PHPeng-Cheng Hu
Peng-Cheng Hu
HFHaijin Fu
Haijin Fu
HYHongxing Yang
Hongxing Yang
Ruitao YangRuitao Yang
Ruitao Yang
JTJiubin Tan
Jiubin Tan
We propose a precision phase-generated-carrier (PGC) demodulation method with sub-nanometer resolution that avoids nonlinear errors in a laser wavelength sinusoidal modulation fiber-optic interferometer for long range dynamic displacement sensing. Using orthogonal detection and an AC-DC component extraction scheme, the PGC carrier phase delay (CPD) and laser intensity modulation phase delay can be obtained simultaneously to eliminate the nonlinear error from accompanied optical intensity modulation and CPD. Further, to realize long range displacement sensing, PGC phase modulation depth (PMD), determined by the laser wavelength modulation amplitude and the working distance of the interferometer, is required to maintain an optimal value during measurement, including initial position and dynamic movement. By combining frequency sweeping interference and modified PGC-arctan demodulation to measure real-time working distance, adaptive PMD technology is realized based on proportion control. We construct a fiber-optic Michelson and SIOS commercial interferometer for comparison and perform experiments to verify the feasibility of the proposed method. Experimental results demonstrate that an interferometer with sub-nanometer resolution and nanometer precision over a large range of 400 mm can be realized.

6 October 2020 in Optics Express
Verified
Journal Article
Closed access
YDYisi Dong
Yisi Dong
PHPeng-Cheng Hu
Peng-Cheng Hu
MRMing Ran
Ming Ran
ZLZhitao Le
Zhitao Le
HFHaijin Fu
Haijin Fu
Ruitao YangRuitao Yang
Ruitao Yang
The phase modulation depth (PMD) in phase-generated-carrier demodulation is determined by the laser frequency modulation amplitude and working distance of a fiber-optic interferometer and must be set at a certain value. Active setting of the amplitude is unsuitable, especially for high-speed modulation, owing to variations in the laser source tuning coefficients. Existing calculation schemes for passive setting cannot work both owing to carrier phase delay (CPD) and the accompanied optical-intensity modulation (AOIM). Herein, a modified phase modulation depth calculation and setting technique is proposed. Double photoelectric detection and signal division are optimized to eliminate AOIM using a fiber delay chain and phase-locked amplifier module. Fast Fourier-transform and look-up table methods are used to calculate phase modulation depth without adding the carrier, which is unaffected by CPD. A fiber-optic Michelson interferometer is constructed to verify the feasibility of the proposed method. The experimental results show that AOIM can be eliminated; moreover, PMD can be calculated and set precisely. The displacement deviation is less than 1.03 nm. The resolution of measurement is considerably lesser than 1 nm and nanoscale accuracy is achieved in displacement measurement.