Lieshan Zhang

Dr. Lieshan Zhang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Optics Communications
Verified
Journal Article
Closed access
LZLieshan Zhang
Lieshan Zhang
WKWeixin Kong
Weixin Kong
MWMeibao Wang
Meibao Wang
RLRongsen Li
Rongsen Li
YWYing Wang
Ying Wang

1 January 2015 in Chinese Optics Letters
Verified
Journal Article
Closed access
LZLieshan Zhang
Lieshan Zhang
XZXiaolin Zhang
Xiaolin Zhang
WTWenyan Tang
Wenyan Tang
To determine the amplitude of weak sinusoidal water surface acoustic wave (WSAW), a method based on the spectrum analysis of the phase-modulated interference signal is developed. Calculated from the amplitude spectrum of the detection signal, a characteristic ratio indicates that the phase-modulation depth of a WSAW is suggested by determining the amplitude of a WSAW according to their functional relationship. Experimental investigations for a 4 kHz WSAW evaluate the measurement’s precision with an amplitude measurement standard deviation of 0.12 nm. The measurement accuracy also is demonstrated by the experimental investigations. The theory of this method is briefly described, and the experimental setup is presented.

29 March 2024 in Applied Acoustics
Verified
Journal Article
Closed access
LZLieshan Zhang
Lieshan Zhang
WXWu Xiao
Wu Xiao
WFWenjun Fang
Wenjun Fang

16 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YCYeqing Chen
Yeqing Chen
YZYi Zeng
Yi Zeng
HLHaoran Li
Haoran Li
JZJiye Zhang
Jiye Zhang
LZLieshan Zhang
Lieshan Zhang
Damping is an important factor contributing to errors in the measurement of rotational inertia using the torsion pendulum method. Identifying the system damping allows for minimizing the measurement errors of rotational inertia, and accurate continuous sampling of torsional vibration angular displacement is the key to realizing system damping identification. To address this issue, this paper proposes a novel method for measuring the rotational inertia of rigid bodies based on monocular vision and the torsion pendulum method. In this study, a mathematical model of torsional oscillation under a linear damping condition is established, and an analytical relationship between the damping coefficient, torsional period, and measured rotational inertia is obtained. A high-speed industrial camera is used to continuously photograph the markers on a torsion vibration motion test bench. After several data processing steps, including image preprocessing, edge detection, and feature extraction, with the aid of a geometric model of the imaging system, the angular displacement of each frame of the image corresponding to the torsion vibration motion is calculated. From the characteristic points on the angular displacement curve, the period and amplitude modulation parameters of the torsion vibration motion can be obtained, and finally the rotational inertia of the load can be derived. The experimental results demonstrate that the proposed method and system described in this paper can achieve accurate measurements of the rotational inertia of objects. Within the range of 0–100 × 10−3 kg·m2, the standard deviation of the measurements is better than 0.90 × 10−4 kg·m2, and the absolute value of the measurement error is less than 2.00 × 10−4 kg·m2. Compared to conventional torsion pendulum methods, the proposed method effectively identifies damping using machine vision, thereby significantly reducing measurement errors caused by damping. The system has a simple structure, low cost, and promising prospects for practical applications.

20 July 2022 in Journal of Vibration Engineering & Technologies
Verified
Journal Article
Closed access
PDF file
LZLieshan Zhang
Lieshan Zhang
XLXincong Li
Xincong Li
JLJunyan Liu
Junyan Liu

23 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PLPu Liu
Pu Liu
LZLieshan Zhang
Lieshan Zhang
MWmeibao Wang
meibao Wang
To address the lack of fast and high-precision in situ measurement of large-sized pipes in current industrial applications, a pipe-diameter-measurement method based on stereo vision is designed in this paper. By using multiple sets of binocular cameras to perform 3D reconstruction and integration of multiple laser markers projected on measured cross sections of pipes, the pipe diameter can be estimated. In this method, a measurement algorithm is adopted to enable automatic matching of feature points through affine distance transformation, and an optimized point-cloud-registration algorithm with normal-vector constraints is used to ensure measurement robustness. To verify the feasibility of the method, an experimental system was built under laboratory conditions, and three types of pipes with outer diameters from 285 mm to 325 mm were measured. The experimental results show that the relative error is within ±0.570% and the maximum repeatability standard deviation is 0.551 mm. The experimental results basically meet industrial standards, and the proposed method therefore has good application prospects.