Measuring the mass and Center of Gravity (CG) of rigid bodies with a multi-point weighing method is widely used nowadays. Traditional methods usually include two parts with a certain location, i.e., a fixed platform and a mobile platform. In this paper, a novel structure is proposed to adjust the mobile platform for eliminating side forces which may load on the load cells. In addition, closed-form equations are formulated to evaluate the performance of the structure, and transformation matrices are used to estimate the characteristics of the structure. Simulation results demonstrate that repeatability of the proposed structure is higher than the traditional one and there are no side forces. Moreover, the measurement results show that the relative error of mass was within 0.05%, and the error of CG was within ±0.3 mm. The structure presented in this paper provides a foundation for practical applications.
22 October 2019 in Measurement Science and Technology
A flexible measurement technique is proposed in this paper to measure the mass and center of gravity of large-sized objects. Based on primary mechanical principles, this technique derives measurement results by fusing data from two different systems. During a test, a high-precision coordinate meter is used to measure reference points in these two systems and designated points in the test object. The measurement results obtained from the two systems are then merged in a single coordinate frame. The proposed flexible measurement technique may be applied to test objects of varying lengths, and meanwhile does not require strict control over the distance between the two measurement systems and that between the test object and the systems. This paper describes basic measurement principles of this technique as well as the data fusion method and transition matrix solving method concerned, which are followed by experiment-based verifications. The test results reveal a mass measurement accuracy of 0.05% and a center of gravity measurement error of within ±1 mm, both meeting high-precision requirements for measuring mass and center of gravity of large-sized objects.
To address the lack of fast and high-precision in situ measurement of large-sized pipes in current industrial applications, a pipe-diameter-measurement method based on stereo vision is designed in this paper. By using multiple sets of binocular cameras to perform 3D reconstruction and integration of multiple laser markers projected on measured cross sections of pipes, the pipe diameter can be estimated. In this method, a measurement algorithm is adopted to enable automatic matching of feature points through affine distance transformation, and an optimized point-cloud-registration algorithm with normal-vector constraints is used to ensure measurement robustness. To verify the feasibility of the method, an experimental system was built under laboratory conditions, and three types of pipes with outer diameters from 285 mm to 325 mm were measured. The experimental results show that the relative error is within ±0.570% and the maximum repeatability standard deviation is 0.551 mm. The experimental results basically meet industrial standards, and the proposed method therefore has good application prospects.
27 November 2020 in Measurement Science and Technology
Sensor noise, such as low-frequency drift and white noise, often causes large measurement errors when an oscillation method is used to determine rotational inertia of a rigid body. A demodulation algorithm based on differentiation and resonance frequency analysis of torsional oscillation signals is proposed in this paper to eliminate the influence of sensor noise on inertia measurement. By using a torsion pendulum method as an example, a measurement approach involving a kinetics differential equation of damped torsional oscillation movement is developed and, on this basis, a rotational inertia measurement function in relation to the amplitude modulation parameter and oscillation frequency is derived. In the proposed algorithm, oscillation detection signals are first differentiated to extract local extremum points and calculate the amplitude modulation parameter. Next, with a certain frequency step, a series of reference signals are constructed and mixed with the original signals. The maximum product sum is calculated to determine the resonance frequency that is exactly equal to the oscillation frequency. Finally, the measurand can be determined by the measurement function. The simulation and experimental results show that this algorithm can effectively reduce the influence of sensor noise on measurement. The comparison of measurement results with other signal processing methods and other measurement systems is carried out, which verifies better effectiveness of the proposed method.
19 June 2023 in Measurement Science and Technology
In order to realize mass and center of gravity measurement of large-sized rotating parts, a set of combined measurement system for center of gravity measurement was developed to adjust the distance according to the length and supporting position of the parts to adapt to different lengths of the measured parts. The study focused on the center of gravity synthesis, error factors and error separation within the system. Firstly, two sets of center of gravity measuring equipment based on multi-point weighing method were used to conduct a joint test on the large-sized measured parts, and the center of gravity measuring model was analyzed. Secondly, the measurement error and its influence on the measurement result are were analyzed when the two sets of measuring equipment were not parallel. Finally, error signals were separated using the multi-step method, Fourier transform and inverse Fourier transform. Simulation experiments show that the residual center of gravity error of Y axis and Z axis is less than 0.3 mm when the tilt angle between two sets of equipment is below 0.3°. The test results demonstrate that the center of gravity measurement error along the X axis is less than 2 mm, which indicates the measurement accuracy better than 0.02% as the length of the test object is about 10 000 mm, and the center of gravity measurement error along the Y axis and Z axis is less than 0.5 mm, which also indicates the measurement accuracy better than 0.02%. These findings indicate that the system enables high-precision measurement of the center of gravity for large-sized rotary products.
Accurate and smooth path tracking is important for autonomous tracked agricultural robots operating in greenhouse-like environments. Existing adaptive look-ahead pure-pursuit methods mainly adjust the look-ahead distance according to vehicle speed or path geometry, while the influence of time-varying localization reliability has not been sufficiently considered. This study proposes a noise-aware adaptive pure-pursuit controller that combines Extended Kalman Filter (EKF) estimation with causal Savitzky–Golay (SG) endpoint smoothing. A bounded look-ahead law is designed by jointly considering normalized vehicle speed, lateral error, path curvature, and an innovation-derived localization-noise indicator. Numerical simulations were conducted on straight, circular, S-shaped, and U-shaped reference paths under prescribed localization disturbances. Under the 0.5 m positional-noise condition, the proposed method achieved an root mean square error (RMSE) of 0.087 m and an angular-velocity root mean square (RMS) of 0.28 rad/s, compared with 0.112 m and 0.36 rad/s, respectively, for conventional fixed-look-ahead pure pursuit. Compared with proportional-integral-derivative (PID), Stanley, model predictive control (MPC), and conventional pure-pursuit controllers, the proposed method provides a favorable balance between tracking accuracy and control smoothness. It also has better computational efficiency than MPC while retaining the low-computational-burden advantage of geometric control. In the sensitivity analysis, the relative RMSE increase from 0.1 to 0.8 m was 36.5% for the proposed method and 103.4% for conventional pure pursuit. These results indicate that the proposed lightweight noise-aware control strategy can improve tracking accuracy, control smoothness, and tolerance to localization disturbances under the specified numerical conditions, providing a practical design reference for low-speed greenhouse agricultural robots.