Various plastic hinge relocation methods were studied to improve the earthquake resistance of emulative precast concrete (PC) beam-column connections using PC U-shell beams. The present study used two strengthening methods (hooked bars and headed bars) and a weakening method (reduced beam bar section), to relocate the plastic hinge zone of beams away from the weak beam-column joint. Five full-scale test specimens including a conventional reinforced concrete (RC) specimen were tested to evaluate the earthquake resistance. The test results showed that the used relocation methods significantly decreased that bond-slip of beam flexural bars and joint shear cracking. As a result, the energy dissipation capacity significantly increased, compared to those of the conventional RC specimens and PC specimens without relocation methods. On the basis of the test results, design recommendations are suggested for plastic hinge relocation design of emulative PC beam-column connections.
3 January 2019 in International Journal of Concrete Structures and Materials
A new lateral force-resisting structural system for concrete high-rise buildings, distributed belt wall system, is proposed. Unlike conventional belt structures, the belt walls infilling the space...
To enhance the structural capacity and constructability of composite columns, a prefabricated steel-reinforced concrete (PSRC) column was developed. By using the prefabricated steel cage, field rebar work is unnecessary, and the self-erectable steel cage can provide sufficient strength and rigidity to support the construction loads of beams and slabs. In the present study, various steel angle ratios, transverse bar spacings, and prefabrication details were considered for better structural capacity and constructability. To investigate the performance of the proposed method, axial loading tests and cyclic lateral loading tests were performed. In the axial loading test, the structural performance of the PSRC columns was comparable to, or even better than, that of the conventional composite column using the wide flange steel section, when early spalling of the cover concrete was restrained by closely spaced hoops. Under cyclic lateral loading, on the other hand, the PSRC columns were more susceptible ...
29 January 2021 in International Journal of Concrete Structures and Materials
This study analytically investigated the behavior of reinforced concrete frames with masonry infills. For the analysis, VecTor2, a nonlinear finite element analysis program that implements the Modified Compression Field Theory and Disturbed Stress Field Model, was used. To account for the slip behavior at the mortar joints in the masonry element, the hyperbolic Mohr–Coulomb yield criterion, defined as a function of cohesion and friction angle, was used. The analysis results showed that the lateral resistance and failure mode of the infilled frames were significantly affected by the thickness of the masonry infill, cohesion on the mortar joint–brick interface, and poor mortar filling (or gap) on the masonry boundary under the beam. Diagonal strut actions developed along two or three load paths on the mortar infill, including the backstay actions near the tension column and push-down actions near the compression columns. Such backstay and push-down actions increased the axial and shear forces of columns, and ultimately affect the strength, ductility, and failure mode of the infilled frames.
1 February 2019 in Journal of Structural Engineering
For existing buildings in low and moderate seismic zones, various nonseismic ties not conforming to special seismic requirements have been used in columns for convenience in reinforcing bar placement. This study investigates the failure mode and deformation capacity of such columns. First, cyclic loading tests of 12 columns with different section geometries, tie details, and axial load ratios are performed. The test results show that postyield shear failure occurs in the columns with nonseismic ties as the inelastic deformation increases, and the ductility of the columns is affected by the spacings and anchorage details of ties. Then, to estimate the deformation capacity of the columns, a postyield shear strength degradation model depending on displacement ductility and tie details is proposed. The proposed method is applied to 80 existing column specimens with a wide range of design parameters. The postyield strength degradation and deformation capacity predicted by the proposed method agree well with the test results.
1 February 2020 in Journal of Structural Engineering
The seismic performance of exterior beam-column joints in low-rise buildings with limited ductility details was investigated. Seven exterior beam-column connection specimens were prepared for cyclic loading tests, and the major test parameters were the column depth and joint shear reinforcement details. In the specimens, joint shear failure occurred before beam or column yielding. The shear strength of the exterior joints increased as the column depth (i.e., joint depth) and the area of shear reinforcements increased. Despite the nonseismic reinforcement details, U-shaped bars and 90°-hooked hoops with a spacing of one-third of the column depth increased the joint shear strength. As a result, flexural beam yielding occurred in several specimens. The joint shear strengths were compared with the predictions by current design codes, and the effects of the test parameters were investigated. Based on the results, a shear strength equation for exterior joints was proposed that is applicable to nonseismic details.