Double skin composite walls are composed of two steel plate “skins” connected by tie bars, with the space between them filled with concrete. They were developed to reduce wall thickness, to enhance constructability, and to enable rapid construction by eliminating the use of formwork and reinforcing bars. In the present study, cyclic testing was performed to investigate the seismic behavior of isolated and coupled double skin composite walls with rectangular and T-shaped cross sections. The wall specimens failed mainly by tensile fracture of the welded joints at the wall base and coupling beams, or by local buckling of the steel plates. Because of their large depth, the ductility of the wall specimens was not as good as that of beams having less depth. In particular, the ductility of the walls was significantly affected by the strengthening methods used for the wall base. The load-carrying capacities of the isolated and coupled wall specimens were evaluated using plastic stress distributions in their cross sections, which provided satisfactory predictions.
An experimental study was performed to investigate the cyclic behavior of framed steel walls with thin infill plates. Five specimens with a single bay and three stories were tested. Test parameters for the specimens were the plate thickness and the strength and compactness of the column. The test results showed that unlike conventional reinforced concrete walls and braced frames, well-designed steel plate walls exhibited large ductility and energy dissipation capacity as well as high strength. The steel plate walls with relatively thin plates showed shear-dominated behavior by the moment–frame action. On the other hand, steel plate walls with thick plates showed flexure-dominated behavior by the cantilever action. The shear-dominated walls showed better ductility. To achieve large ductility, the boundary columns must resist the combined axial force and transverse force developed by the tension–field action of the infill plates. Also, the columns must have compact sections to prevent their early local buckling.
An experimental study was performed to investigate the structural capacity of steel plate walls with various infill plate designs. Five three-story steel plate shear walls with thin infill plates were tested. The parameters for this test were the connection method between the boundary frame and the infill plate (welded connection versus bolted connection), length of the welded connection (full connection versus partial connection), and opening in the infill plate (solid wall versus coupled wall). Regardless of the infill plate design, the steel plate wall specimens exhibited excellent strength, deformation capacity, and energy dissipation capacity, although the walls with bolt-connected infill plates exhibited a slightly lower deformation capacity. This result indicates that for architectural reasons and enhancement of constructability, various infill plate designs can be used in practice without a significant reduction in the structural capacity of the steel plate walls. The strength and energy dissipati...
1 August 2012 in Journal of Structural Engineering
Seven concrete-encased steel columns using high-strength steel (nominal yield strength fys=913 and 806 MPa) and high-strength concrete (cylinder compressive strength fc′=94 and 113 MPa) were tested to investigate the eccentric axial load-carrying capacity and the deformation capacity. The test parameters were full or partial concrete-encasement, the eccentricity of the axial load, and the effect of lateral reinforcement. Because the yield strain (≈0.004) of the high-strength steel is greater than the ultimate compressive strain (≈0.003) of the concrete subjected to short-term loads, the current study focused on the effect of early concrete crushing on the behavior of the composite columns. The test results showed that in the case of inadequate lateral confinement, the load-carrying capacity was limited by the early crushing of concrete. However, because of the high-strength steel section, all test specimens showed ductile flexural behavior after the delamination of the concrete. The test results w...
1 February 2016 in Journal of Structural Engineering
Various plastic hinge relocation methods were studied to improve the earthquake resistance of emulative precast concrete (PC) beam-column connections using PC U-shell beams. The present study used two strengthening methods (hooked bars and headed bars) and a weakening method (reduced beam bar section), to relocate the plastic hinge zone of beams away from the weak beam-column joint. Five full-scale test specimens including a conventional reinforced concrete (RC) specimen were tested to evaluate the earthquake resistance. The test results showed that the used relocation methods significantly decreased that bond-slip of beam flexural bars and joint shear cracking. As a result, the energy dissipation capacity significantly increased, compared to those of the conventional RC specimens and PC specimens without relocation methods. On the basis of the test results, design recommendations are suggested for plastic hinge relocation design of emulative PC beam-column connections.
1 September 2008 in Journal of Structural Engineering
An experimental study was performed to investigate the potential maximum ductility and energy dissipation capacity of steel plate walls with thin infill plates. Three specimens of a three-story steel plate wall were tested. A concentrically braced frame (CBF) and a moment-resisting frame (MRF) were also tested for comparison. To maximize the ductility and energy dissipation capacity of the steel plate walls, ductile details were used. The test parameters were the aspect ratio of the infill plate and the shear strength of the column. The steel plate walls exhibited much better ductility and energy dissipation capacity as compared to the CBF and MRF. This result indicates that unlike conventional reinforced concrete walls and CBFs, shear-dominated steel plate walls with thin infill plates possess excellent ductility capacity as well as high strength and stiffness. Based on the results of previous studies and the present study, the variations in the ductility and the energy dissipation capacity of the steel ...