We present a new technique, differential ghost imaging (DGI), which dramatically enhances the signal-to-noise ratio (SNR) of imaging methods based on spatially correlated beams. DGI can measure the transmission function of an object in absolute units, with a SNR that can be orders of magnitude higher than the one achievable with the conventional ghost imaging (GI) analysis. This feature allows for the first time, to our knowledge, the imaging of weakly absorbing objects, which represents a breakthrough for GI applications. Theoretical analysis and experimental and numerical data assessing the performances of the technique are presented.
High-resolution ghost image and ghost diffraction experiments are performed by using a single classical source of pseudothermal speckle light divided by a beam splitter. Passing from the image to the diffraction result solely relies on changing the optical setup in the reference arm, while leaving the object arm untouched. The product of spatial resolutions of the ghost image and ghost diffraction experiments is shown to overcome a limit which seemed to be achievable only with entangled photons.
We investigate experimentally fundamental properties of coherent ghost imaging using spatially incoherent beams generated from a pseudo-thermal source. A complementarity between the coherence of the beams and the correlation between them is demonstrated by showing a complementarity between ghost diffraction and ordinary diffraction patterns. In order for the ghost imaging scheme to work it is therefore crucial to have incoherent beams. The visibility of the information is shown for the ghost image to become better as the object size relative to the speckle size is decreased, and therefore a remarkable tradeoff between resolution and visibility exists. The experimental conclusions are backed up by both theory and numerical simulations.
In this Letter we present experimental results concerning the retrieval of images of absorbing objects immersed in turbid media via differential ghost imaging (DGI) in a backscattering configuration. The method has been applied, for the first time to our knowledge, to the imaging of thin black objects located inside a turbid solution in proximity of its surface. We show that it recovers images with a contrast better than standard noncorrelated direct imaging, but equivalent to noncorrelated diffusive imaging. A simple theoretical model capable of describing the basic optics of DGI in turbid media is proposed.
We study fast, salt-induced aggregation of polystyrene spheres by means of low-angle static light scattering covering two decades of scattered wave vector q. The measurements are taken at a fixed salt concentration, varying the monomer concentration from =1× to 5× . During each run, the fractal dimension of the clusters and the time evolution of the average radius 〈〉 and average mass 〈M are determined. At larger concentrations we consistently find =1.61±0.02, but, as the concentration is decreased, grows to 1.83±0.02. The value of is determined both from the asymptotic behavior of the scattered intensity I(q) and from the relation between the average mass and radius, I(0)∝. Good agreement is found between the two sets of data. The earlier portions of the curves for as a function of time t are compatible with a power-law growth and collapse onto a master curve when the reduced time T=t is used. Noticeable deviations from power-law growth are, however, observed at later times. Finally, we show that for the lowest concentrations the reactions stop when the clusters attain a maximum diameter. We present arguments showing that reaction termination is due to sedimentation, the time required to diffuse across intercluster distance becoming longer than the settling time through the sample due to sedimentation.
A charge coupled device (CCD) camera has been successfully used to implement a low-angle elastic light scattering setup. A novel optical detection layout brings all the light scattered by the sample directly onto the CCD, optimizing the instrument sensitivity. The detectable angular range covers ∼2 decades, from ∼0.1° to ∼10°. The calibration of the instrument, as well as the estimate of its sensitivity, accuracy, dynamic range and linearity, can be carried out by using single pinholes. Experimental results from pinholes and diluted suspensions of polystyrene spheres are presented.