Matteo Molteni

Matteo Molteni

Auto-generated profile, based on publicly available information

Matteo Molteni

Dipartimento di Scienza e Alta Tecnologia and To.Sca.Lab, Università dell'Insubria, Via Valleggio 11, 22100 Como, Italy

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2013 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MBM. Bina
M. Bina
DMD. Magatti
D. Magatti
MMM. Molteni
M. Molteni
AGA. Gatti
A. Gatti
LLL. A. Lugiato
L. A. Lugiato
FFFabio Ferri
Fabio Ferri
In this Letter we present experimental results concerning the retrieval of images of absorbing objects immersed in turbid media via differential ghost imaging (DGI) in a backscattering configuration. The method has been applied, for the first time to our knowledge, to the imaging of thin black objects located inside a turbid solution in proximity of its surface. We show that it recovers images with a contrast better than standard noncorrelated direct imaging, but equivalent to noncorrelated diffusive imaging. A simple theoretical model capable of describing the basic optics of DGI in turbid media is proposed.

1 March 2013 in Biophysical Journal
Verified
Journal Article
Closed access
MMMatteo Molteni
Matteo Molteni
DMDavide Magatti
Davide Magatti
BCBarbara Cardinali
Barbara Cardinali
MRMattia Rocco
Mattia Rocco
FFFabio Ferri
Fabio Ferri

1 April 2014 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
MRMattia Rocco
Mattia Rocco
MMMatteo Molteni
Matteo Molteni
MPMarco Ponassi
Marco Ponassi
GGGuido Giachi
Guido Giachi
Marco FredianiMarco Frediani
Marco Frediani
JPJavier Pérez
Javier Pérez

21 July 2015 in Macromolecules
Verified
Journal Article
Closed access
FFFabio Ferri
Fabio Ferri
GCGabriele Re Calegari
Gabriele Re Calegari
MMMatteo Molteni
Matteo Molteni
BCBarbara Cardinali
Barbara Cardinali
DMDavide Magatti
Davide Magatti
MRMattia Rocco
Mattia Rocco

1 March 2013 in Biophysical Journal
Verified
Journal Article
Open access
PDF file
DMDavide Magatti
Davide Magatti
MMMatteo Molteni
Matteo Molteni
BCBarbara Cardinali
Barbara Cardinali
MRMattia Rocco
Mattia Rocco
FFFabio Ferri
Fabio Ferri
Fibrin gels have been the subject of countless studies due to their fundamental importance in the process of blood coagulation. They constitute the network inside which platelets and other blood components are trapped, forming the hemostatic plug that stops bleeding ( 1 x Fibrinogen and fibrin. Weisel, J.W. Adv. Protein Chem. 2005; 70: 247–299 Crossref | PubMed | Scopus (380) See all References 1 ). Fibrin gels also play important roles in other pathological and physiological situations, such as thrombosis and cancer (the latter because some tumoral cells are known to migrate through fibrin networks ( 2 x Cancer and blood coagulation. Boccaccio, C. and Medico, E. Cell. Mol. Life Sci. 2006; 63: 1024–1027 Crossref | PubMed | Scopus (21) See all References 2 )). They exhibit extraordinary physical and mechanical characteristics (e.g., elasticity, extendibility, and resistance), and, given their natural origin, are fully biocompatible materials. As a consequence, they are ideal substrates for many biotechnological applications, ranging from surgery (e.g., adhesives and sealants called fibrin glues) to tissue engineering (specific cell growth for tissue regeneration) and drug delivery. A recent review on fibrin gels and their biotechnological applications can be found in Janmey et al. ( 3 x Fibrin gels and their clinical and bioengineering applications. Janmey, P.A., Winer, J.P., and Weisel, J.W. J. R. Soc. Interface. 2009; 6: 1–10 Crossref | PubMed | Scopus (210) See all References 3 ).

1 November 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MMMatteo Molteni
Matteo Molteni
FFFabio Ferri
Fabio Ferri
A 10 ns time resolution, multi-tau software correlator, capable of computing simultaneous autocorrelation (A-A, B-B) and cross (A-B) correlation functions at count rates up to ∼10 MHz, with no data loss, has been developed in LabVIEW and C++ by using the National Instrument timer/counterboard (NI PCIe-6612) and a fast Personal Computer (PC) (Intel Core i7-4790 Processor 3.60 GHz ). The correlator works by using two algorithms: for large lag times (τ ≳ 1 μs), a classical time-mode scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ ≲ 1 μs a photon-mode (PM) scheme is adopted and the correlation function is retrieved from the sequence of the photon arrival times. Single auto- and cross-correlation functions can be processed online in full real time up to count rates of ∼1.8 MHz and ∼1.2 MHz, respectively. Two autocorrelation (A-A, B-B) and a cross correlation (A-B) functions can be simultaneously processed in full real time only up to count rates of ∼750 kHz. At higher count rates, the online processing takes place in a delayed modality, but with no data loss. When tested with simulated correlation data and latex spheres solutions, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.