The development of carbon dots (CDs), either using green or chemical precursors, has inevitably led to their wide range application, from bioimaging to optoelectronic devices. The reported precursors and properties of these CDs have opened new opportunities for the future development of high-quality CDs and applications. Green precursors were classified into fruits, vegetables, flowers, leaves, seeds, stem, crop residues, fungi/bacteria species, and waste products, while the chemical precursors were classified into acid reagents and non-acid reagents. This paper quickly reviews ten years of the synthesis of CDs using green and chemical precursors. The application of CDs as sensing materials in optical sensor techniques for environmental monitoring, including the detection of heavy metal ions, phenol, pesticides, and nitroaromatic explosives, was also discussed in this review. This profound review will offer knowledge for the upcoming community of researchers interested in synthesizing high-quality CDs for various applications.
Great efforts have been devoted to the invention of environmental sensors as the amount of water pollution has increased in recent decades. Chitosan, cellulose and nanocrystalline cellulose are examples of biopolymers that have been intensively studied due to their potential applications, particularly as sensors. Furthermore, the rapid use of conducting polymer materials as a sensing layer in environmental monitoring has also been developed. Thus, the incorporation of biopolymer and conducting polymer materials with various methods has shown promising potential with sensitively and selectively toward heavy metal ions. In this feature paper, selected recent and updated investigations are reviewed on biopolymer and conducting polymer-based materials in sensors aimed at the detection of heavy metal ions by optical methods. This review intends to provide sufficient evidence of the potential of polymer-based materials as sensing layers, and future outlooks are considered in developing surface plasmon resonance as an excellent and valid sensor for heavy metal ion detection.
The emergence of unintentional poisoning and uncontrolled vector diseases have contributed to sensor technologies development, leading to the more effective detection of diseases. In this study, we present the combination of graphene-based material with surface plasmon resonance technique. Two different graphene-based material sensor chips were prepared for rapid and quantitative detection of dengue virus (DENV) and cobalt ion (Co2+) as an example of typical metal ions. As the fundamental concept of surface plasmon resonance (SPR) sensor that relies on the refractive index of the sensor chip surface, this research focused on the SPR signal when the DENV and Co2+ interact with the graphene-based material sensor chip. The results demonstrated that the proposed sensor-based graphene layer was able to detect DENV and Co2+ as low as 0.1 pM and 0.1 ppm respectively. Further details in the detection and quantification of analyte were also discussed in terms of sensitivity, affinity, and selectivity of the sensor.
The modification of graphene quantum dots (GQDs) may drastically enhance their properties, therefore resulting in various related applications. This paper reported the preparation of novel cetyltrimethylammonium bromide/hydroxylated graphene quantum dots (CTAB/HGQDs) thin film using the spin coating technique. The properties of the thin film were then investigated and studied. The functional groups existing in CTAB/HGQDs thin film were confirmed by the Fourier transform infrared (FTIR) spectroscopy, while the atomic force microscope (AFM) displayed a homogenous surface of the thin film with an increase in surface roughness upon modification. Optical characterizations using UV-Vis absorption spectroscopy revealed a high absorption with an optical band gap of 4.162 eV. Additionally, the photoluminescence (PL) spectra illustrated the maximum emission peak of CTAB/HGQDs thin film at a wavelength of 444 nm. The sensing properties of the as-prepared CTAB/HGQDs thin film were studied using a surface plasmon resonance technique towards the detection of several heavy metal ions (HMIs) (Zn2+, Ni2+, and Fe3+). This technique generated significant results and showed that CTAB/HGQDs thin film has great potential for HMIs detection.
In this study, highly functional cationically modified nanocrystalline cellulose (NCC)/carboxyl-functionalized graphene quantum dots (CGQD) has been described. The surface of NCC was first modified with hexadecyltrimethylammonium bromide (CTA) before combining with CGQD. The CGQD, CTA-NCC and CTA-NCC/CGQD nanocomposites thin films were prepared using spin coating technique. The obtained nanocomposite thin films were then characterized by using the Fourier transform infrared spectroscopy (FTIR) which confirmed the existence of hydroxyl groups, carboxyl groups and alkyl groups in CTA-NCC/CGQD. The optical properties of the thin films were characterized using UV–Vis spectroscopy. The absorption of CTA-NCC/CGQD was high with an optical band gap of 4.127 eV. On the other hand, the CTA-NCC/CGQD nanocomposite thin film showed positive responses towards glucose solution of different concentration using an optical method based on surface plasmon resonance phenomenon. This work suggests that the novel nanocomposite thin film has potential for a sensing application in glucose detection.
There are extensive studies on the development of composite solutions involving various types of materials. Therefore, this works aims to incorporate two polymers of nanocrystalline cellulose (NCC) and poly(3,4-ethylenethiophene) (PEDOT) to develop a composite thin film via the spin-coating method. Then, Fourier transform infrared (FTIR) spectroscopy is employed to confirm the functional groups of the NCC/PEDOT thin film. The atomic force microscopy (AFM) results revealed a relatively homogeneous surface with the roughness of the NCC/PEDOT thin film being slightly higher compared with individual thin films. Meanwhile, the ultraviolet/visible (UV/vis) spectrometer evaluated the optical properties of synthesized thin films, where the absorbance peaks can be observed around a wavelength of 220 to 700 nm. An optical band gap of 4.082 eV was obtained for the composite thin film, which is slightly lower as compared with a single material thin film. The NCC/PEDOT thin film was also incorporated into a plasmonic sensor based on the surface plasmon resonance principle to evaluate the potential for sensing mercury ions in an aqueous medium. Resultantly, the NCC/PEDOT thin film shows a positive response in detecting the various concentrations of mercury ions. In conclusion, this work has successfully developed a new sensing layer in fabricating an effective and potential heavy metal ions sensor.