Manuel Morgano

Dr. Manuel Morgano

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
PBP. Boillat
P. Boillat
CCChiara Carminati
Chiara Carminati
FSF. Schmid
F. Schmid
CGC. Grünzweig
C. Grünzweig
JHJ. Hovind
J. Hovind
ELE.H. Lehmann
E.H. Lehmann
We propose a method for improving the quantification of neutron imaging measurements with scintillator-camera based detectors by correcting for systematic biases introduced by scattered neutrons and other sources such as light reflections in the detector system. This method is fully experimental, using reference measurements with a grid of small black bodies (BB) to measure the bias contributions directly. Using two test samples, one made of lead alloy and having a moderate (20%) neutron transmission and one made of stainless-steel and having a very low (1%) transmission, we evaluated the improvement brought by this method in reducing both the average quantification bias and the uncertainty around this average bias after tomographic reconstruction. The results show that a reduction of the quantification bias of up to one order of magnitude can be obtained. For moderately transparent samples, little sensitivity is observed to the parameters used for the correction. For the more challenging sample with very low transmission, a correct placement of the BB grid is of utmost importance for a successful correction.

1 August 2014 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MMManuel Morgano
Manuel Morgano
SPS. Peetermans
S. Peetermans
ELEberhard Lehmann
Eberhard Lehmann
TPT. Panzner
T. Panzner
UFU. Filges
U. Filges

17 January 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
MMManuel Morgano
Manuel Morgano
PTP. Trtik
P. Trtik
MMM. Meyer
M. Meyer
ELE. H. Lehmann
E. H. Lehmann
JHJ. Hovind
J. Hovind
MSM. Strobl
M. Strobl
The demand for high resolution neutron imaging has been steadily increasing over the past years. The number of facilities offering cutting edge resolution is however limited, due to (i) the design complexity of an optimized device able to reach a resolution in the order of ≈ 10 μm and (ii) limitations in available neutron flux. Here we propose a simple addition, based on a Fibre Optics Taper (FOT), that can be easily attached to an already existing scintillator-camera imaging detector in order to efficiently increase its spatial resolution and hence boost the capability of an instrument into high resolution applications.

23 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
Efthymios PolatidisEfthymios Polatidis
Efthymios Polatidis
MMManuel Morgano
Manuel Morgano
FMFlorencia Malamud
Florencia Malamud
MBMichael Bacak
Michael Bacak
TPTobias Panzner
Tobias Panzner
Markus StroblMarkus Strobl
Markus Strobl
The transformation induced plasticity (TRIP) effect is investigated during a load path change using a cruciform sample. The transformation properties are followed by in-situ neutron diffraction derived from the central area of the cruciform sample. Additionally, the spatial distribution of the TRIP effect triggered by stress concentrations is visualized using neutron Bragg edge imaging including, e.g., weak positions of the cruciform geometry. The results demonstrate that neutron diffraction contrast imaging offers the possibility to capture the TRIP effect in objects with complex geometries under complex stress states.

6 October 2016 in MethodsX
Verified
Journal Article
Open access
PTPavel Trtik
Pavel Trtik
MMManuel Morgano
Manuel Morgano
RBRoman Bentz
Roman Bentz
ELEberhard Lehmann
Eberhard Lehmann
The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neutron imaging. In order to partially overcome the neutron intensity problem for the high temporal resolution imaging, a parabolic neutron focussing guide was utilized in the test arrangement and placed upstream the detector in such a manner that the focal point of the guide was positioned slightly behind the scintillator screen. In such a test arrangement, the neutron flux can be increased locally by about one order of magnitude, albeit with the reduced spatial resolution due to the increased divergence of the neutron beam. In a pilot test application, an in-situ titration system allowing for a remote delivery of well-defined volumes of liquids onto the sample stage was utilized. The process of droplets of water (H2O) falling into the container filled with heavy water (D2O) and the subsequent process of the interaction and mixing of the two liquids were imaged with temporal resolution of 0.01 s.

1 December 2017 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
JKJ. Karch
J. Karch
JDJan Dudak
Jan Dudak
JŽJ. Žemlička
J. Žemlička
DVDaniel Vavřík
Daniel Vavřík
IKIvana Kumpova
Ivana Kumpova
PTP. Trtík
P. Trtík
Computed tomography provides 3D information of inner structures of investigated objects. The obtained information is, however, strongly dependent on the used radiation type. It is known that as X-rays interact with electron cloud and neutrons with atomic nucleus, the obtained data often provide different contrast of sample structures. In this work we present a set of comparative radiographic and CT measurements of rare fossil plant samples using X-rays and thermal neutrons. The X-ray measurements were performed using large area photon counting detectors Timepix at IEAP CTU in Prague and Perkin Elmer flat-panel detector at Center of Excellence Telč. The neutron CT measurement was carried out at Paul Scherrer Institute using BOA beam-line. Furthermore, neutron radiography of fossil samples, provided by National Museum, were performed using a large-area Timepix detector with a neutron-sensitive converting 6LiF layer at Research Centre Rez, Czech Republic. The obtained results show different capabilities of both imaging approaches. While X-ray micro-CT provides very high resolution and enables visualization of fine cracks or small cavities in the samples neutron imaging provides high contrast of morphological structures of fossil plant samples, where X-ray imaging provides insufficient contrast.