Le Minh Nhut

Dr. Le Minh Nhut


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
LNLe Minh Nhut
Le Minh Nhut
WRWaseem Raza
Waseem Raza
YPYoun Cheol Park
Youn Cheol Park
The requirement for energy is increasing worldwide as populations and economies develop. Reasons for this increase include global warming, climate change, an increase in electricity demand, and paucity of fossil fuels. Therefore, research in renewable energy technology has become a central topic in recent studies. In this study, a solar-assisted house heating system with a seasonal underground thermal energy storage tank is proposed based on the reference system to calculate the insulation thickness effect, the collector area, and an underground storage tank volume on the system performance according to real weather conditions at Jeju Island, South Korea. For this purpose, a mathematical model was established to calculate its operating performance. This mathematical model used the thermal response factor method to calculate the heat load and heat loss of the seasonal underground thermal energy storage tank. The results revealed that on days with different weather conditions, namely, clear weather, intermittent clouds sky, and overcast sky, the obtained solar fraction was 45.8%, 17.26%, and 0%, respectively. Using this method, we can save energy, space, and cost. This can then be applied to the solar-assisted house heating system in South Korea using the seasonal underground thermal energy storage tank.

27 February 2023 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
LNLe Minh Nhut
Le Minh Nhut
HMHa Nguyen Minh
Ha Nguyen Minh
LNLuan Nguyen
Luan Nguyen
The present work investigates the exergy and effective efficiency of the multi-pass solar air collector with longitudinal fins by analysis approach and multi-objective optimization. The effect of 0.01-0.02 kg/s air flow rate, 15-35 mm collector depth, 1-3 m collector length, and 24.21-30.67 mm fin pitch was considered. The optimization was analyzed by the Preference Selection Index (PSI) method, with three maximum criteria: thermal efficiency, effective efficiency, and exergy efficiency. Mathematical models were solved by EES software. Results indicated that the multi-pass (TPLF and DPLF) type was better than the SPWF type by three criteria. The highest exergy efficiency of the TPLF and DPLF types was 6.696% and 5.636%. The greatest effective efficiency of the TPLF and DPLF types was 69.09% and 66.17%. Furthermore, the optimization results indicated that the three efficiency criteria of the DPLF type were 58.38%, 58.22%, and 4.491% for the best case; the three efficiency criteria of the TPLF type were 60.97%, 60.85%, and 5.439% for the best case. The worst configuration was the model with a short collector length, large collector depth, and large fin pitch. The collector efficiency decreased with decreased fin pitch for the configuration with the large collector length, short collector depth, and high mass flow rate.

3 June 2016 in International Journal of Mechanical Engineering and Applications
Verified
Journal Article
Open access
PDF file
LNLe Minh Nhut
Le Minh Nhut
YMYoung-Sub Moon
Young-Sub Moon
YPYoun Cheol Park
Youn Cheol Park
The objective of this research is the optimization of energy parameters such as the temperature and flow rate of the fluid in heat exchangers in the gasification system in order to increase the recovery rate of energy in the system. A mathematical model of these heat exchangers is developed to predict their operating performance under the specified gasification system. The optimal flow rate and temperature of the fluid in the heat exchanger based on the effectiveness - number of transfer units(NTU) method is investigated. The result of the simulation shows that the optimal mass flow rate and temperature of the high pressure (HP) boiler feed water are determined at 175,907 kg/h and 110°C, respectively, while the optimal mass flow rate and temperature of high pressure saturated steam of boiler are determined at 238,430 kg/h, 290.5°C, respectively. At these values, the total heat amount obtained at these heat exchangers is highest with 169 MW. Besides, the total heat amount obtained at heat exchangers could be increased by 4.61% (7.8 MW) when sixty percent of the heat release amount from air cooler (12.78 MW) is used.

3 July 2020 in Science & Technology Development Journal - Engineering and Technology
Verified
Journal Article
Open access
PDF file
LNLe Minh Nhut
Le Minh Nhut
TDTran Quang Danh
Tran Quang Danh
Hot water is an important factor in domestic life and industrial development. Today, the heat pump is used to produce hot water more and more popular because it has many advantages of saving energy compared to the method of producing hot water by the hot water electric heater. The main aim of this study is to evaluate of the coefficient of performance (COP) of the small hot water heat pump using refrigeration R410A and R32. The capacity of both hot water heat pump is similar, one using new refrigerant R32 and other using refrigerant R410A. These heat pumps were designed and installed at the Ho Chi Minh City University of Technology and Education to evaluate the COP for the purpose of application the new refrigerant R32 for hot water heat pump. The compressor capacity is 1 Hp, the volume of hot water storage tank is of 100 liters and is insulated with thickness of 30 mm to reduce the heat loss to invironment, the required hot water temperature at the outlet of condenser is 50 oC, and the amount of required hot water is 75 liters per batch and is controlled by float valve. The experimental results indicate that the COP of the heat pump using the new refrigerant R32 is higher than heat pump using refrigerant R410A from 9% to 15% when the experimental conditions such as ambient temperature, initial water flow rate through the condenser and the required temperature of hot water were the same. In addition, the effect of the ambient temperature, initial water temperature and water flow rate were also evaluated.

27 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
LNLe Minh Nhut
Le Minh Nhut
YPYoun Cheol Park
Youn Cheol Park
In this study, based on the optimal equation m = 0.05 Δ T A c (kg/min) of the variable mass flow rate in the collector loop, an automatic controller with an inverter collector pump for the collector loop of the solar-assisted heating system is designed for these experiments and to then be used for real industry. The pump for the collector loop is an inverter type that is controlled by an embedded controller with Windows, based on C# language, and the change of speed depends on the variation of the mass flow rate through the collector loop. The input of the automatic controller with an inverter collector pump is given by a thermocouple input module that is connected to the embedded controller with the RS-485 communication protocol. In this work, the experiments were carried out on three different days, namely a clear day, an intermittently cloudy day and an overcast day, to evaluate the stability and the precision of the automatic controller, as well as the contribution of the useful heat gain from the collector for the solar-assisted heating system. Simulation and experimental results are also validated and analyzed.

9 September 2025 in Journal of Technical Education Science
Verified
Journal Article
Open access
PDF file
TPThanh Huy Phan
Thanh Huy Phan
QLquang huy le
quang huy le
LNLe Minh Nhut
Le Minh Nhut
Bài báo trình bày kết quả thực nghiệm thu nước ngọt từ không khí khi sử dụng hệ thống lạnh công suất nhỏ dùng môi chất lạnh R290. Trong nghiên cứu này, một hệ thống lạnh công suất nhỏ sử dụng môt chất lạnh R290 được thiết kế, chế tạo và lắp đặt tại khu vực Thành phố Hồ Chí Minh để đánh giá sử ảnh hưởng của điều kiện môi trường đến các thông số nhiệt động của hệ thống này trong quá trình thu nước ngọt từ không khí. Kết quả thí nghiệm ở điều kiện trời nắng cho thấy rằng, khi nhiệt độ và độ ẩm môi trường giao động trong khoản từ 28 oC đến 37 oC và 38% đến 70%, thì nhiệt độ và áp suất ngưng tụ dao động từ 41 oC đến 49 oC và 13 đến 15,8 bar, trong khi đó nhiệt độ và áp suất bay hơi lần lượt là 3,6 oC đến 6,2 oC và 4,3 đến 4,7 bar. Trong khi đó, lượng nước thu được trong ngày thí nghiệm từ 8h đến 16h là 7,85 lít ứng với điện năng tiêu thụ là 7,55 kW.