X-ray imaging has proved invaluable in medical diagnoses and non-destructive testing (NDT) in the past century. However, there remain two major limitations: radiation harm and inaccessibility to the sample. A recent imaging modality, X-ray induced acoustic computed tomography (XACT), allows a novel solution. In XACT, x-ray induced excitation causes localized heating (
10 June 2023 in Applied Catalysis B: Environment and Energy
This paper presents a photoacoustic non-destructive evaluation (pNDE) system with an ultrahigh resolution for the detection of multi-scale damage in carbon fiber-reinforced plastic (CFRP) composites. The pNDE system consists of three main components: a picosecond pulsed laser-based ultrasonic actuator, an ultrasound receiver, and a data acquisition/computing subsystem. During the operation, high-frequency ultrasound is generated by pulsed laser and recorded by an ultrasound receiver. By implementing a two-dimensional back projection algorithm, pNDE images can be reconstructed from the recorded ultrasound signals to represent the embedded damage. Both potential macroscopic and microscopic damages, such as surface notches and delamination in CFRP, can be identified by examining the reconstructed pNDE images. Three ultrasonic presentation modes including A-scan, B-scan, and C-scan are employed to analyze the recorded signals for the representation of the detected micro-scale damage in two-dimensional and three-dimensional images with a high spatial resolution of up to 60 µm. Macro-scale delamination and transverse ply cracks are clearly visualized, identifying the edges of the damaged area. The results of the study demonstrate that the developed pNDE system provides a non-destructive and robust approach for multi-scale damage detection in composite materials.
In this Letter, we propose a novel triplex-parameter detection method to realize simultaneous radiometric, photoacoustic, and ultrasonic imaging based on single-pulse excitation. The optical attenuation, optical absorption, and acoustic impedance properties can be obtained simultaneously by analyzing the photoacoustic signals and the ultrasonic echo signals. To test the feasibility and accuracy of this method, agar phantoms with different absorption coefficients and elastic coefficients were measured. Then, this method was experimentally verified by imaging a leaf skeleton piece embedded in an agar cylinder. Furthermore, pilot experiments were performed by triplex imaging of pig ear tissue ex vivo to characterize the cartilage and surrounding tissue. Experimental results demonstrated that this technique has future potentials for visualizing and providing the functional and structural information of biological tissues.