X-ray-induced acoustic computed tomography (XACT) provides X-ray absorption-based contrast with acoustic detection. For its clinical translation, XACT imaging often has a limited field of view. This can result in image artifacts and overall loss of quantification accuracy. In this article, we aim to demonstrate model-based XACT image reconstruction to address these problems. An efficient matrix-free implementation of the regularized LSQR (MF-LSQR)-based minimization scheme and a noniterative model back-projection (MBP) scheme for computing XACT reconstructions have been demonstrated in this article. The proposed algorithms have been numerically validated and then used to perform reconstructions from experimental measurements obtained from an XACT setup. While the commonly used back-projection (BP) algorithm produces limited-view and noisy artifacts in the region of interest (ROI), model-based LSQR minimization overcomes these issues. The model-based algorithms also reduce the ring artifacts caused due to the nonuniformity response of the multichannel data acquisition. Using the model-based reconstruction algorithms, we are able to obtain reasonable XACT reconstructions for acoustic measurements of up to 120° view. Although the MBP is more efficient than the model-based LSQR algorithm, it provides only the structural information of the ROI. Overall, it has been demonstrated that the model-based image reconstruction yields better image quality for XACT than the standard BP. Moreover, the combination of model-based image reconstruction with different regularization methods can solve the limited-view problem for XACT imaging (in many realistic cases where the full-view dataset is unavailable), and hence pave the way for future clinical translation.
26 March 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
X-ray-induced acoustic computed tomography (XACT) is a unique hybrid imaging modality that combines high X-ray absorption contrast with high ultrasonic resolution. X-ray radiography and computerized tomography (CT) are currently the gold standards for 2-D and 3-D imaging of skeletal tissues though there are important properties of bone, such as elasticity and speed of sound (SOS), that these techniques cannot measure. Ultrasound is capable of measuring such properties though current clinical ultrasound scanners cannot be used to image the interior morphology of bones because they fail to address the complicated physics involved for exact image reconstruction; bone is heterogeneous and composed of layers of both cortical and trabecular bone, which violates assumptions in conventional ultrasound imaging of uniform SOS. XACT, in conjunction with the time-reversal algorithm, is capable of generating precise reconstructions, and by combining elements of both X-ray and ultrasound imaging, XACT is potentially capable of obtaining more information than any single of these techniques at low radiation dose. This article highlights X-ray-induced acoustic detection through linear scanning of an ultrasound transducer and the time-reversal algorithm to produce the first-ever XACT image of a bone sample. The results of this study should prove to enhance the potential of XACT imaging in the evaluation of bone diseases for future clinical use.
X-ray-induced acoustic computed tomography (XACT) has emerged as a promising imaging modality with broad applications in both biomedicine and nondestructive testing. The previous XACT imaging systems require thousands of averages to achieve reasonable images. Here, we report the experimental demonstration of single-shot XACT imaging of a metal object using a single-shot 50 ns x-ray pulse. A two-stage dedicated amplification and a 128-channel parallel data acquisition configuration were introduced for XACT imaging to enable sufficient acoustic signal amplification and maintain an overall low noise level for single-shot XACT imaging. Details of the system design are presented; the improved signal-to-noise ratio (>23 dB) and image reconstruction have been demonstrated with a ring ultrasound transducer array imaging system. The study paves the way for realizing real-time XACT imaging and its potential applications in image-guided intervention.
19 January 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
X-ray-induced acoustic (XA) computerized tomography (XACT) is an evolving imaging technique that aims to reconstruct the X-ray energy deposition from XA measurements. Main challenges in XACT are the poor signal-to-noise ratio and limited field-of-view, which cause artifacts in the images. We demonstrate the efficacy of model-based (MB) algorithms for 3-D XACT and compare with the traditional algorithms. The MB algorithms are based on the matrix free approach for regularized-least-squares minimization corresponding to XACT. The matrix-free-LSQR (MF-LSQR) and the noniterative model-backprojection (MBP) reconstructions were evaluated and compared with universal backprojection (UBP), time-reversal (TR), and fast-Fourier transform (FFT)-based reconstructions for numerical and experimental XACT datasets. The results demonstrate the capability of the MF-LSQR algorithm to reduce noisy artifacts thus yielding better reconstructions. MBP and MF-LSQR algorithms perform particularly well with the experimental XACT dataset, where noise in signals significantly affects the reconstruction of the target in UBP and FFT-based reconstructions. The TR reconstruction for experimental XACT is comparable to MF-LSQR, but takes thrice as much time and filters the frequency components greater than maximum frequency supported by the grid, resulting loss of resolution. The MB algorithms are able to overcome the challenges in XACT and hence are vital for the clinical translation of XACT.
10 August 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
X-ray-induced acoustic computed tomography (XACT) is a promising imaging modality to monitor the position of the radiation beam and the deposited dose during external beam radiotherapy delivery. The purpose of this study was to investigate the feasibility of using a transperineal ultrasound (TPUS) transducer array for XACT imaging to guide the prostate radiotherapy. A customized 2-D matrix ultrasound transducer array with 10000 ( 100×100 elements) ultrasonic sensors with a central frequency of 1 MHz was designed on a 5 cm ×5 cm plane to optimize 3-D volumetric imaging. The CT scan and dose treatment plan for a prostate patient undergoing intensity-modulated radiation therapy (IMRT) were obtained. The in-house simulation was developed to model the time varying X-ray induced acoustic (XA) signals detected by the TPUS array. A 3-D filtered back projection (FBP) algorithm has been used for 3-D XACT image reconstruction. The results of this study will greatly enhance the potential of XACT imaging for real-time in vivo dosimetry during radiotherapy.
This paper presents a photoacoustic non-destructive evaluation (pNDE) system with an ultrahigh resolution for the detection of multi-scale damage in carbon fiber-reinforced plastic (CFRP) composites. The pNDE system consists of three main components: a picosecond pulsed laser-based ultrasonic actuator, an ultrasound receiver, and a data acquisition/computing subsystem. During the operation, high-frequency ultrasound is generated by pulsed laser and recorded by an ultrasound receiver. By implementing a two-dimensional back projection algorithm, pNDE images can be reconstructed from the recorded ultrasound signals to represent the embedded damage. Both potential macroscopic and microscopic damages, such as surface notches and delamination in CFRP, can be identified by examining the reconstructed pNDE images. Three ultrasonic presentation modes including A-scan, B-scan, and C-scan are employed to analyze the recorded signals for the representation of the detected micro-scale damage in two-dimensional and three-dimensional images with a high spatial resolution of up to 60 µm. Macro-scale delamination and transverse ply cracks are clearly visualized, identifying the edges of the damaged area. The results of the study demonstrate that the developed pNDE system provides a non-destructive and robust approach for multi-scale damage detection in composite materials.