Mark Kielpinski

Mr. Mark Kielpinski

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RIR. Ijsselsteijn
R. Ijsselsteijn
MKMark Kielpinski
Mark Kielpinski
SWS. Woetzel
S. Woetzel
TST. Scholtes
T. Scholtes
EKE. Kessler
E. Kessler
HMH.-G. Meyer
H.-G. Meyer
We show the operation of an optically pumped magnetometer array in a 50 μT magnetic field. The various components for a fully optical and non-magnetic detector unit were constructed and evaluated, from which a prototype unit was assembled with fiber coupled electronics. In this unit the magnetometers were operated using the intensity modulated method and heated with an off-resonant laser. Calculations on the temperature distribution were used to design the magnetometer array. Different magnetometers in such a detector unit were characterized and showed identical performance. Without applying noise reduction schemes, the obtained magnetic field resolution is a factor 2.5 above the shot noise level down to frequencies of about 7 Hz.

10 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
MKMark Kielpinski
Mark Kielpinski
OWOliver Walther
Oliver Walther
Jialan CaoJialan Cao
Jialan Cao
THThomas Henkel
Thomas Henkel
Johann KöhlerJohann Köhler
Johann Köhler
GGG. Alexander Groß
G. Alexander Groß
The defined formation and expansion of droplets are essential operations for droplet-based screening assays. The volumetric expansion of droplets causes a dilution of the ingredients. Dilution is required for the generation of concentration graduation which is mandatory for many different assay protocols. Here, we describe the design of a microfluidic operation unit based on a bypassed chamber and its operation modes. The different operation modes enable the defined formation of sub-µL droplets on the one hand and the expansion of low nL to sub-µL droplets by controlled coalescence on the other. In this way the chamber acts as fluidic interface between two fluidic network parts dimensioned for different droplet volumes. Hence, channel confined droplets of about 30–40 nL from the first network part were expanded to cannel confined droplets of about 500 to about 2500 nL in the second network part. Four different operation modes were realized: (a) flow rate independent droplet formation in a self-controlled way caused by the bypassed chamber design, (b) single droplet expansion mode, (c) multiple droplet expansion mode, and (d) multiple droplet coalescence mode. The last mode was used for the automated coalescence of 12 droplets of about 40 nL volume to produce a highly ordered output sequence with individual droplet volumes of about 500 nL volume. The experimental investigation confirmed a high tolerance of the developed chamber against the variation of key parameters of the dispersed-phase like salt content, pH value and fluid viscosity. The presented fluidic chamber provides a solution for the problem of bridging different droplet volumes in a fluidic network.