12 October 2011 in Physical Review A
We demonstrate a way of operating an optically pumped magnetometer with miniaturized cesium cell using the light-narrowing effect. The magnetometer setup shows improvement of shot-noise-limited sensitivity (42fT/Hz in a cell of only 9.3mm3 volume) due to the suppression of spin-exchange relaxation to a large extent and the use of a strikingly increased fraction of alkali-metal atoms for signal generation, working even in $\mu${}T magnetic fields, by using only a single high-intensity laser beam both for pumping and probing of atomic spins.
7 February 2018 in Physical Review D
Light (pseudo-)scalar fields are promising candidates to be the dark matter in the Universe. Under certain initial conditions in the early Universe and/or with certain types of self-interactions, they can form compact dark-matter objects such as axion stars or -balls. Direct encounters with such objects can be searched for by using a global network of atomic magnetometers. It is shown that for a range of masses and radii not ruled out by existing observations, the terrestrial encounter rate with axion stars or -balls can be sufficiently high (at least once per year) for a detection. Furthermore, it is shown that a global network of atomic magnetometers is sufficiently sensitive to pseudoscalar couplings to atomic spins so that a transit through an axion star or -ball could be detected over a broad range of unexplored parameter space.
11 February 2022 in Physical Review Applied
We present a portable optically pumped magnetometer instrument for ultrasensitive measurements within the Earth’s magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift dispersed mode. It is connected to a compact, battery-driven electronics module by a flexible cable. We briefly review the working principles of the device and detail the realization of both the sensor head and electronics. We show shielded and unshielded measurements within a static magnetic field amplitude of , demonstrating a noise level of the sensor system down to and a sensor bandwidth of several 100 Hz. In a detailed analysis of sensor noise, we reveal the system to be limited by technical sources with straightforward strategies for further improvement toward its fundamental noise limit of . We assess the parameters defining the sensor bandwidth by theoretical modeling based on the Bloch equations. Finally, we compare our sensors’ performance to a commercial superconducting quantum interference device system in a measurement environment typical for geomagnetic observatory practice and geomagnetic prospection.
1 December 2018 in Physics of the Dark Universe
1 May 2020 in Physics of the Dark Universe