Hepatic steatosis as the most prevalent liver disorder can either be related to alcoholic liver disease (ALD) or non-alcoholic fatty liver disease (NAFLD). In both conditions, hepatocytes excessively accumulate fat-containing vacuoles within their cytoplasm, which is the key histological feature. In contrast to ALD, NAFLD is commonly associated with metabolic syndrome, obesity and insulin resistance. To determine increased liver fat content, liver biopsy is currently considered the gold standard. Besides the invasive technique, various other non-invasive techniques have been developed, such as ultrasound, computed tomography (CT), magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) based methods. Among these techniques, ultrasound and CT provide only qualitative information about hepatic steatosis, whereas MRS- or MRI-based methods are able to determine even small amounts of fat accurately. These non-invasive magnetic resonance techniques have already proven their great potential, especially in longitudinal and cross-sectional studies regarding various metabolic conditions and medical treatment regimens. In this review, the most common, non-invasive MRS/MRI techniques for assessment of intrahepatic lipid content are described with their inherent advantages and limitations.
18 December 2007 in CardioVascular and Interventional Radiology
Objective With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions and implants. Relaxation behavior and signal yield were evaluated on a 3-Tesla whole-body MR unit. Materials and Methods: Nine different commonly used solid polymeric materials were investigated by means of a 3-dimensional (3D) UTE sequence with radial k-space sampling. The investigated polymeric samples with cylindrical shape (length, 150 mm; diameter, 30 mm) were placed in a commercial 8-channel knee coil. For assessment of transverse signal decay (T2*) images with variable echo times (TE) ranging from 0.07 milliseconds to 4.87 milliseconds were recorded. Spin-lattice relaxation time (T1) was calculated for all MR visible polymers with transverse relaxation times higher than T2* = 300 μs using an adapted method applying variable flip angles. Signal-to-noise ratio (SNR) was calculated at the shortest achievable echo time (TE = 0.07 milliseconds) for standardized sequence parameters. All relaxation times and SNR data are given as arithmetic mean values with standard deviations derived from 5 axially oriented slices placed around the isocenter of the coil and magnet. Results: Six of the 9 investigated solid polymers were visible at TE = 0.07 milliseconds. Visible solid polymers showed markedly different SNR values, ie, polyethylene SNR = 1146 ± 41, polypropylene SNR = 60 ± 6. Nearly mono-exponential echo time dependent signal decay was observed: Transverse relaxation times differed from T2*=36 ± 5 μs for polycarbonate to T2*=792 ± 7 μs for polyvinylchloride (PVC). Two of the investigated solid polymers were applicable to T1 relaxation time calculation. Polyurethane had a spin-lattice relaxation time of T1 = 172 ± 1 milliseconds, whereas PVC had T1 = 262 ± 7 milliseconds, respectively. Conclusions: A variety of solid polymers can be visualized by means of clinical whole-body MR scanners and 3D ultrashort echo time (UTE) sequences. The investigated polymers differ substantially in signal yield, signal-decay, and spin-lattice relaxation time. The knowledge of the signal behavior of solid polymers on whole-body clinical MR scanners may help to select suitable polymeric materials for instruments and implants which are visible using UTE sequences.
Objectives: To develop suitable strategies for quantification of longitudinal relaxation time (T1) by means of ultrashort echo time (UTE) sequences and the variable flip-angle approach in materials and tissues with extremely fast signal decay. Materials and Methods: A recently published modified Ernst equation, which correctly accounts for in-pulse relaxation of transverse magnetization, was used to numerically determine optimal flip angles for reliable assessment of T1 in case of extremely short effective transverse relaxation time (T2*). Various ratios of repetition time (TR) to T1 and radiofrequency (RF) pulse duration (TRF) to T2* were evaluated. Theoretical considerations were applied to solid polymeric material (T2* = 0.295 milliseconds), and T1 quantification was performed using various optimized flip-angle approaches at different RF pulse durations (TRF = 0.1–0.4 milliseconds). Furthermore, in vivo measurement of T1 in cortical bone was exemplarily performed in 3 healthy volunteers to test the applicability of the proposed method in vivo. For in vitro and in vivo studies, MR imaging was performed on a 3 T whole-body MR system using a 3D UTE sequence with a rectangular excitation pulse and centric radial readout. Results: Optimal flip angles were shown to be strongly dependent on TR/T1 and TRF/T2* ratios. Exemplarily, longitudinal relaxation time of the investigated solid polymeric material was determined to T1 = 223.1 ± 3.1 milliseconds with RF pulse duration of TRF = 0.2 milliseconds, and 12 acquired flip angles ranging from 5 to 60 degrees. Using only 2 optimized flip angles (8 degrees, 44 degrees), T1 of the same material was determined to T1 = 223.8 ± 4.2 milliseconds in a markedly less acquisition time. In vivo evaluation of cortical bone was feasible and showed T1 values of 80.4 ± 25.1 milliseconds, exemplarily. Conclusions: Using the modified Ernst equation, it seems possible to rapidly evaluate 3D distribution of longitudinal relaxation time in materials and tissues with extremely fast signal decay by means of UTE sequences and only 2 measurements with optimized flip angles.
18 December 2013 in Journal of Magnetic Resonance Imaging