The precise evaluation of electromagnetic field (EMF) distributions inside biological samples is becoming an increasingly important design requirement for high field MRI systems. In evaluating the induced fields caused by magnetic field gradients and RF transmitter coils, a multilayered dielectric spherical head model is proposed to provide a better understanding of electromagnetic interactions when compared to a traditional homogeneous head phantom. This paper presents Debye potential (DP) and Dyadic Green's function (DGF)-based solutions of the EMFs inside a head-sized, stratified sphere with similar radial conductivity and permittivity profiles as a human head. The DP approach is formulated for the symmetric case in which the source is a circular loop carrying a harmonic-formed current over a wide frequency range. The DGF method is developed for generic cases in which the source may be any kind of RF coil whose current distribution can be evaluated using the method of moments. The calculated EMFs can then be used to deduce MRI imaging parameters. The proposed methods, while not representing the full complexity of a head model, offer advantages in rapid prototyping as the computation times are much lower than a full finite difference time domain calculation using a complex head model. Test examples demonstrate the capability of the proposed models/methods. It is anticipated that this model will be of particular value for high field MRI applications, especially the rapid evaluation of RF resonator (surface and volume coils) and high performance gradient set designs.
Entropy provides a valuable tool for quantifying the regularity of physiological time series and provides important insights for understanding the underlying mechanisms of the cardiovascular system. Before any entropy calculation, certain common parameters need to be initialized: embedding dimension m, tolerance threshold r and time series length N. However, no specific guideline exists on how to determine the appropriate parameter values for distinguishing congestive heart failure (CHF) from normal sinus rhythm (NSR) subjects in clinical application. In the present study, a thorough analysis on the selection of appropriate values of m, r and N for sample entropy (SampEn) and recently proposed fuzzy measure entropy (FuzzyMEn) is presented for distinguishing two group subjects. 44 long-term NRS and 29 long-term CHF RR interval recordings from http://www.physionet.org were used as the non-pathological and pathological data respectively. Extreme (>2 s) and abnormal heartbeat RR intervals were firstly removed from each RR recording and then the recording was segmented with a non-overlapping segment length N of 300 and 1000, respectively. SampEn and FuzzyMEn were performed for each RR segment under different parameter combinations: m of 1, 2, 3 and 4, and r of 0.10, 0.15, 0.20 and 0.25 respectively. The statistical significance between NSR and CHF groups under each combination of m, r and N was observed. The results demonstrated that the selection of m, r and N plays a critical role in determining the SampEn and FuzzyMEn outputs. Compared with SampEn, FuzzyMEn shows a better regularity when selecting the parameters m and r. In addition, FuzzyMEn shows a better relative consistency for distinguishing the two groups, that is, the results of FuzzyMEn in the NSR group were consistently lower than those in the CHF group while SampEn were not. The selections of m of 2 and 3 and r of 0.10 and 0.15 for SampEn and the selections of m of 1 and 2 whenever r (herein, rL = rG = r) are for FuzzyMEn (in addition to setting nL = 3 and nG = 2) were recommended to yield the fine classification results for the NSR and CHF groups.
Compressed Sensing (CS) has been applied in dynamic Magnetic Resonance Imaging (MRI) to accelerate the data acquisition without noticeably degrading the spatial-temporal resolution. A suitable sparsity basis is one of the key components to successful CS applications. Conventionally, a multidimensional dataset in dynamic MRI is treated as a series of two-dimensional matrices, and then various matrix/vector transforms are used to explore the image sparsity. Traditional methods typically sparsify the spatial and temporal information independently. In this work, we propose a novel concept of tensor sparsity for the application of CS in dynamic MRI, and present the Higher-order Singular Value Decomposition (HOSVD) as a practical example. Applications presented in the three- and four-dimensional MRI data demonstrate that HOSVD simultaneously exploited the correlations within spatial and temporal dimensions. Validations based on cardiac datasets indicate that the proposed method achieved comparable reconstruction accuracy with the low-rank matrix recovery methods and, outperformed the conventional sparse recovery methods.
Compressed sensing MRI (CS-MRI) aims to significantly reduce the measurements required for image reconstruction in order to accelerate the overall imaging speed. The sparsity of the MR images in transformation bases is one of the fundamental criteria for CS-MRI performance. Sparser representations can require fewer samples necessary for a successful reconstruction or achieve better reconstruction quality with a given number of samples. Generally, there are two kinds of 'sparsifying' transforms: predefined transforms and data-adaptive transforms. The predefined transforms, such as the discrete cosine transform, discrete wavelet transform and identity transform have usually been used to provide sufficiently sparse representations for limited types of MR images, in view of their isolation to the object images. In this paper, we present singular value decomposition (SVD) as the data-adaptive 'sparsity' basis, which can sparsify a broader range of MR images and perform effective image reconstruction. The performance of this method was evaluated for MR images with varying content (for example, brain images, angiograms, etc), in terms of image quality, reconstruction time, sparsity and data fidelity. Comparison with other commonly used sparsifying transforms shows that the proposed method can significantly accelerate the reconstruction process and still achieve better image quality, providing a simple and effective alternative solution in the CS-MRI framework.