The human opposable thumb enables the hand to perform dexterous manipulation of objects, which requires well-coordinated digit force vectors. This study investigated the directional coordination of force vectors generated by the thumb and index finger during precision pinch. Fourteen right-handed, healthy subjects were instructed to exert pinch force on an externally stabilized apparatus with the pulps of the thumb and index finger. Subjects applied forces to follow a force-ramp profile that linearly increased from 0 to 12 N and then decreased to 0 N, at a rate of ±3 N/s. Directional relationships between the thumb and index finger force vectors were quantified using the coordination angle (CA) between the force vectors. Individual force vectors were further analyzed according to their projection angles (PAs) with respect to the pinch surface planes and the shear angles (SAs) within those planes. Results demonstrated that fingertip force directions were dependent on pinch force magnitude, especially at forces below 2 N. Hysteresis was observed in the force-CA relationship for increasing and decreasing forces and fitted with exponential models. The fitted asymptotic values were 156.0±6.6° and 150.8±9.3° for increasing and decreasing force ramps, respectively. The PA of the thumb force vector deviated further from the direction perpendicular to the pinching surface planes than that of the index finger. The SA showed that the index finger force vector deviated in the ulnar-proximal direction, whereas the thumb switched its force between the ulnar-proximal and radial-proximal directions. The findings shed light on the effects of anatomical composition, biomechanical function, and neuromuscular control in coordinating digit forces during precision pinch, and provided insight into the magnitude-dependent force directional control which potentially affects a range of dexterous manipulations.
Reduced knee flexion is a leading feature of post-stroke gait, but the causes have not been well understood. The purpose of this study was to investigate the relationship between the knee flexion and the lower-limb muscle activation within the stance-to-swing phases of gait cycle in the post-stroke hemiplegic patients. Ten stroke patients and 10 age- and gender-matched healthy subjects participated in the experiment. The lower-limb kinematic signals and the surface electromyography (sEMG) signals of the left and right rectus femoris (RF), biceps femoris (BF) and lateral gastrocnemius (GS) were recorded during walking. The angle range (AR) of knee flexion, the root mean square (RMS) and the mean frequency (MNF) of sEMG signals were calculated from the terminal stance (TSt) to the initial swing (ISw) phases of gait cycle. Stroke patients showed lower bilateral AR of knee flexion and lower RMS of GS on the paretic side, but higher MNF of RF on the non-paretic side compared with the controls. Within the stroke patients, significant differences were found between their paretic and non-paretic limbs in the AR of knee flexion, as well as in the RMS and MNF of GS (p < 0.05). Regression analysis showed that the RMS of BF, MNF of BF and MNF of GS explained 82.1% of variations in AR of knee flexion on paretic side (r2 = 0.821). But the RMS and MNF of all the muscles (including the RF, GS and BF) could explain 65.6% of AR of knee flexion variations on the non-paretic side (r2 = 0.656), and 45.2% of variations for the healthy subjects (r2 = 0.452). The reduced knee flexion during gait was associated with altered magnitude and frequency of muscle contractions and with simplified muscle synergy in the post-stroke hemiplegic patients. Identifying the muscles that are responsible for knee stiffness may facilitate improvement of rehabilitation strategy for post-stroke gait.
The human hand plays a role in a variety of daily activities. This intricate instrument is vulnerable to trauma or neuromuscular disorders. Wearable robotic exoskeletons are an advanced technology with the potential to remarkably promote the recovery of hand function. However, the still face persistent challenges in mechanical and functional integration, with real-time control of the multiactuators in accordance with the motion intentions of the user being a particular sticking point. In this study, we demonstrated a newly-designed wearable robotic hand exoskeleton with multijoints, more degrees of freedom (DOFs), and a larger range of motion (ROM). The exoskeleton hand comprises six linear actuators (two for the thumb and the other four for the fingers) and can realize both independent movements of each digit and coordinative movement involving multiple fingers for grasp and pinch. The kinematic parameters of the hand exoskeleton were analyzed by a motion capture system. The exoskeleton showed higher ROM of the proximal interphalangeal and distal interphalangeal joints compared with the other exoskeletons. Five classifiers including support vector machine (SVM), K-near neighbor (KNN), decision tree (DT), multilayer perceptron (MLP), and multichannel convolutional neural networks (multichannel CNN) were compared for the offline classification. The SVM and KNN had a higher accuracy than the others, reaching up to 99%. For the online classification, three out of the five subjects showed an accuracy of about 80%, and one subject showed an accuracy over 90%. These results suggest that the new wearable exoskeleton could facilitate hand rehabilitation for a larger ROM and higher dexterity and could be controlled according to the motion intention of the subjects.