Dagong Jia

Dr. Dagong Jia

College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Dagong JiaDagong Jia
Dagong Jia
JCJing Chao
Jing Chao
SLShuai Li
Shuai Li
HZHongxia Zhang
Hongxia Zhang
YYYingzhan Yan
Yingzhan Yan
YSYe Sun
Ye Sun
In this paper, we report the design and experimental validation of a novel optical sensor for radial artery pulse measurement based on fiber Bragg grating (FBG) and lever amplification mechanism. Pulse waveform analysis is a diagnostic tool for clinical examination and disease diagnosis. High fidelity radial artery pulse waveform has been investigated in clinical studies for estimating central aortic pressure, which is proved to be predictors of cardiovascular diseases. As a three-dimensional cylinder, the radial artery needs to be examined from different locations to achieve optimal pulse waveform for estimation and diagnosis. The proposed optical sensing system is featured as high sensitivity and immunity to electromagnetic interference for multilocation radial artery pulse waveform measurement. The FBG sensor can achieve the sensitivity of 8.236 nm/N, which is comparable to a commonly used electrical sensor. This FBG-based system can provide high accurate measurement, and the key characteristic parameters can be then extracted from the raw signals for clinical applications. The detecting performance is validated through experiments guided by physicians. In the experimental validation, we applied this sensor to measure the pulse waveforms at various positions and depths of the radial artery in the wrist according to the diagnostic requirements. The results demonstrate the high feasibility of using optical systems for physiological measurement and using this FBG sensor for radial artery pulse waveform in clinical applications.

8 August 2022 in ACS Photonics
Verified
Journal Article
Closed access
JZJing Zhao
Jing Zhao
SZSiyue Zhang
Siyue Zhang
YSYe Sun
Ye Sun
NZNing Zhou
Ning Zhou
HYHui Yu
Hui Yu
Dagong JiaDagong Jia
Dagong Jia

18 December 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
RWRuihang Wang
Ruihang Wang
JZJing Zhao
Jing Zhao
YSYe Sun
Ye Sun
HYHui Yu
Hui Yu
NZNing Zhou
Ning Zhou
Dagong JiaDagong Jia
Dagong Jia
Continuous respiratory monitoring is extensively important in clinical applications. To effectively assess respiration rate (RR), tidal volume (TV), and minute ventilation (MV), we propose and experimentally demonstrate a respiration monitoring system using an in-line few-mode fiber Mach-Zehnder interferometer (FMF-MZI), which is the first to introduce in-line MZI into an optimal wearable design for respiration rate and volume monitoring. The optimal linear region of the proposed sensor is analyzed and positioned by a flexible arch structure with curvature sensitivity up to 8.53 dB/m−1. Respiration monitoring results are in good agreement with a standard spirometer among different individuals. The difference in TV estimation is ± 0.2 L, and the overall error of MV estimation is less than 5%.

25 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YZYongkun Zhao
Yongkun Zhao
HZHongxia Zhang
Hongxia Zhang
QJQingwen Jin
Qingwen Jin
Dagong JiaDagong Jia
Dagong Jia
TLTiegen Liu
Tiegen Liu
In this study, a ratiometric optical fiber dissolved oxygen sensor based on dynamic quenching of fluorescence from a ruthenium complex is reported. Tris(4,7-diphenyl-1,10-phenanthrolin) ruthenium(II) dichloride complex (Ru(dpp)32+) is used as an oxygen-sensitive dye, and semiconductor nanomaterial CdSe/ZnS quantum dots (QDs) are used as a reference dye by mixing the two substances and coating it on the plastic optical fiber end to form a composite sensitive film. The linear relationship between the relative fluorescence intensity of the ruthenium complex and the oxygen concentration is described using the Stern–Volmer equation, and the ruthenium complex doping concentration in the sol-gel film is tuned. The sensor is tested in gaseous oxygen and aqueous solution. The experimental results indicate that the measurement of dissolved oxygen has a lower sensitivity in an aqueous environment than in a gaseous environment. This is due to the uneven distribution of oxygen in aqueous solution and the low solubility of oxygen in water, which results in a small contact area between the ruthenium complex and oxygen in solution, leading to a less-severe fluorescence quenching effect than that in gaseous oxygen. In detecting dissolved oxygen, the sensor has a good linear Stern–Volmer calibration plot from 0 to 18.25 mg/L, the linearity can reach 99.62%, and the sensitivity can reach 0.0310/[O2] unit. The salinity stability, repeatability, and temperature characteristics of the sensor are characterized. The dissolved oxygen sensor investigated in this research could be used in various marine monitoring and environmental protection applications.

26 June 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Caiming SunCaiming Sun
Caiming Sun
ZCZhen Chen
Zhen Chen
FTFei Teng
Fei Teng
QWQi Wang
Qi Wang
JLJing Lin
Jing Lin
AZAidong Zhang
Aidong Zhang
In order to acquire the tracking information across a rotary joint, a dynamic frequency-modulated continuous-wave (FMCW) laser ranging system is designed to couple through a rotary interface. A setup for FMCW light detection and ranging (LiDAR) is proposed to couple through a fiber optic rotary joint (FORJ), whose optical path is able to eliminate the influence of rotary coupling on the generation of beat frequency. This FMCW LiDAR uses real-time correction for nonlinear laser chirps by synchronizing the FMCW measurement signals with laser injection current at data acquisition (DAQ). Then, phase variations induced by rotary coupling are excluded from the FMCW measurements. The acquisition rate is kept much higher than the rotation speed of FORJ, in order to reduce the influence of rotary coupling on the real-time nonlinearity correction. The linearization of laser frequency modulation through a FORJ is conducted by resampling of over 3000 intervals interpolated in every up-sweep or down-sweep of 25 μs, with measurement signals stretched or compressed in time domain. With the FORJ rotating at the speed of 10°/s in both clockwise and anticlockwise directions, the clear and robust beat signals are achieved. The statistical distributions of measured 50-cm distance under rotary conditions are found out to be similar to that under stationary condition.

18 November 2022 in Molecules
Verified
Journal Article
Open access
PDF file
QWQi Wu
Qi Wu
HZHongxia Zhang
Hongxia Zhang
Dagong JiaDagong Jia
Dagong Jia
TLTiegen Liu
Tiegen Liu
Liquid opens up a new stage of device tunability and gradually replaced solid-state devices and mechanical tuning. It optimizes the control method and improves the dynamic range of many optical devices, exhibiting several attractive features, such as rapid prototyping, miniaturization, easy integration and low power consumption. The advantage makes optical devices widely used in imaging, optical control, telecommunications, autopilot and lab-on-a-chip. Here, we review the tunable liquid devices, including isotropic liquid and anisotropic liquid crystal devices. Due to the unique characteristics of the two types of liquids, the tuning principles and tuning methods are distinguished and demonstrated in detail firstly and then some recent progress in this field, covering the adaptive lens, beam controller, beam filter, bending waveguide, iris, resonator and display devices. Finally, the limitations and future perspectives of the current liquid devices are discussed.