Background: Accurate segmentation and recognition algorithm of lung nodules has great important value of reference for early diagnosis of lung cancer. An algorithm is proposed for 3D CT sequence images in this paper based on 3D Res U-Net segmentation network and 3D ResNet50 classification network. The common convolutional layers in encoding and decoding paths of U-Net are replaced by residual units while the loss function is changed to Dice loss after using cross entropy loss to accelerate network convergence. Since the lung nodules are small and rich in 3D information, the ResNet50 is improved by replacing the 2D convolutional layers with 3D convolutional layers and reducing the sizes of some convolution kernels, 3D ResNet50 network is obtained for the diagnosis of benign and malignant lung nodules. Results: 3D Res U-Net was trained and tested on 1044 CT subcases in the LIDC-IDRI database. The segmentation result shows that the Dice coefficient of 3D Res U-Net is above 0.8 for the segmentation of lung nodules larger than 10 mm in diameter. 3D ResNet50 was trained and tested on 2960 lung nodules in the LIDC-IDRI database. The classification result shows that the diagnostic accuracy of 3D ResNet50 is 87.3% and AUC is 0.907. Conclusion: The 3D Res U-Net module improves segmentation performance significantly with the comparison of 3D U-Net model based on residual learning mechanism. 3D Res U-Net can identify small nodules more effectively and improve its segmentation accuracy for large nodules. Compared with the original network, the classification performance of 3D ResNet50 is significantly improved, especially for small benign nodules.
Continuous respiratory monitoring is extensively important in clinical applications. To effectively assess respiration rate (RR), tidal volume (TV), and minute ventilation (MV), we propose and experimentally demonstrate a respiration monitoring system using an in-line few-mode fiber Mach-Zehnder interferometer (FMF-MZI), which is the first to introduce in-line MZI into an optimal wearable design for respiration rate and volume monitoring. The optimal linear region of the proposed sensor is analyzed and positioned by a flexible arch structure with curvature sensitivity up to 8.53 dB/m−1. Respiration monitoring results are in good agreement with a standard spirometer among different individuals. The difference in TV estimation is ± 0.2 L, and the overall error of MV estimation is less than 5%.
Bone segmentation is important in computed tomography (CT) imaging of the pelvis, which assists physicians in the early diagnosis of pelvic injury, in planning operations, and in evaluating the effects of surgical treatment. This study developed a new algorithm for the accurate, fast, and efficient segmentation of the pelvis. The proposed method consists of two main parts: the extraction of key frames and the segmentation of pelvic CT images. Key frames were extracted based on pixel difference, mutual information and normalized correlation coefficient. In the pelvis segmentation phase, skeleton extraction from CT images and a marker-based watershed algorithm were combined to segment the pelvis. To meet the requirements of clinical application, physician’s judgment is needed. Therefore the proposed methodology is semi-automated. In this paper, 5 sets of CT data were used to test the overlapping area, and 15 CT images were used to determine the average deviation distance. The average overlapping area of the 5 sets was greater than 94%, and the minimum average deviation distance was approximately 0.58 pixels. In addition, the key frame extraction efficiency and the running time of the proposed method were evaluated on 20 sets of CT data. For each set, approximately 13% of the images were selected as key frames, and the average processing time was approximately 2 min (the time for manual marking was not included). The proposed method is able to achieve accurate, fast, and efficient segmentation of pelvic CT image sequences. Segmentation results not only provide an important reference for early diagnosis and decisions regarding surgical procedures, they also offer more accurate data for medical image registration, recognition and 3D reconstruction.
Objective : Cervical cancer is one of the two biggest killers of women and early detection of cervical precancerous lesions can effectively improve the survival rate of patients. Manual diagnosis by combining colposcopic images and clinical examination results is the main clinical diagnosis method at present. Developing an intelligent diagnosis algorithm based on artificial intelligence is an inevitable trend to solve the objectification of diagnosis and improve the quality and efficiency of diagnosis. Approach : A colposcopic multimodal fusion convolutional neural network (CMF-CNN) was proposed for the classification of cervical lesions. Mask region convolutional neural network was used to detect the cervical region while the encoding network EfficientNet-B3 was introduced to extract the multimodal image features from the acetic image and iodine image. Finally, Squeeze-and-Excitation, Atrous Spatial Pyramid Pooling, and convolution block were also adopted to encode and fuse the patient’s clinical text information. Main results : The experimental results showed that in 7106 cases of colposcopy, the accuracy, macro F1-score, macro-areas under the curve of the proposed model were 92.70%, 92.74%, 98.56%, respectively. They are superior to the mainstream unimodal image classification models. Significance : CMF-CNN proposed in this paper combines multimodal information, which has high performance in the classification of cervical lesions in colposcopy, so it can provide comprehensive diagnostic aid.
22 April 2024 in Computers in Biology and Medicine
In this paper, we propose an approach to improve the sensitivity of an optical fiber surface plasmon resonance (SPR) sensor with a pure higher-order mode excited by a designed mode selective coupler (MSC). We calculate the proportion of the power of the higher-order mode in the cladding. Compared to the mode, the power proportion of the mode ( mode) in the cladding theoretically improves by 100% (150%). To generate a relatively pure mode or mode, a mode selective coupler (MSC, 430–580 nm) is designed. The coupling efficiency of the mode coupler is over 80%, and that of the mode coupler is over 50%. The simulation results show that the sensitivity of the mode and the mode increases by approximately 330% and 360%, respectively, using the intensity modulation (n = 1.33–1.38, 430–580 nm); the resolution of the refractive indices of our sensor, using the mode ( mode), is RIU ( RIU). The higher sensitivity and resolution of our presented fiber SPR sensor containing a visible MSC make it a promising candidate for the measurement of refractive indices.