Monika Janik

Dr. Monika Janik

1. Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warszawa, Poland
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Monika JanikMonika Janik
Monika Janik
MKMarcin Koba
Marcin Koba
ACAnna Celebańska
Anna Celebańska
WBWojtek J. Bock
Wojtek J. Bock
Mateusz SmietanaMateusz Smietana
Mateusz Smietana
The paper presents the first study to date on selective label-free biosensing with a microcavity in-line Mach-Zehnder interferometer induced in an optical fiber. The sensing structures were fabricated in a single-mode fiber by femtosecond laser micromachining. In contrast to other studies of this sensing scheme, where only the sensitivity to refractive index changes in the cavity was investigated, this research used chemical surface treatment of the sensor to ensure detection specificity. Immobilized MS2 bacteriophages were applied as recognition elements specifically targeting live E. coli C3000 bacteria. It is shown that the sensor allows for real-time monitoring of biological phenomena taking place on the surface of the microcavity. The developed biosensor exhibits ultrahigh refractive index sensitivity of 15,000 nm/RIU and is capable of detecting live E. coli bacteria concentrations as low as 100 colony forming units (CFU)/mL in liquid volume as low as picoliters.

26 November 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Monika JanikMonika Janik
Monika Janik
SHSeyed Vahid Hamidi
Seyed Vahid Hamidi
MKMarcin Koba
Marcin Koba
JPJonathan Perreault
Jonathan Perreault
RWRyan Walsh
Ryan Walsh
Mateusz SmietanaMateusz Smietana
Mateusz Smietana
Rolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), where rapid, sensitive, and reliable test results are required.

12 October 2017 in Optics Express
Verified
Journal Article
Closed access
PDF file
Mateusz SmietanaMateusz Smietana
Mateusz Smietana
Monika JanikMonika Janik
Monika Janik
MKMarcin Koba
Marcin Koba
WBWojtek J. Bock
Wojtek J. Bock
In this work we discuss the refractive index (RI) sensitivity of a micro-cavity in-line Mach-Zehnder interferometer in the form of a cylindrical hole (40-50 μm in diameter) fabricated in a standard single-mode optical fiber using a femtosecond laser. The surface of the micro-cavity was coated with up to 400 nm aluminum oxide thin film using the atomic layer deposition method. Next, the film was progressively chemically etched and the influence on changes in the RI of liquid in the micro-cavity was determined at different stages of the experiment, i.e., at different thicknesses of the film. An effect of transition between sensitivity to the film thickness (surface) and the RI of liquid in the cavity (bulk) is demonstrated for the first time. We have found that depending on the interferometer working conditions determined by thin film properties, the device can be used for investigation of phenomena taking place at the surface, such as in case of specific label-free biosensing applications, or for small-volume RI analysis as required in analytical chemistry.

5 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Tinko EftimovTinko Eftimov
Tinko Eftimov
Monika JanikMonika Janik
Monika Janik
MKMarcin Koba
Marcin Koba
Mateusz SmietanaMateusz Smietana
Mateusz Smietana
PMPredrag Mikulic
Predrag Mikulic
WBWojtek Bock
Wojtek Bock
Selected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water environments, which is as high as 20,000 nm/RIU (Refractive index unit) for DTP-LPGs and 27,000 nm/RIU for µIMZIs. Special attention is paid to the methods to enhance the sensitivity by etching and nano-coatings. While the DTP-LPGs offer a greater interaction length and sensitivity to changes taking place at their surface, the µIMZIs are best suited for investigations of sub-nanoliter and picoliter volumes. The capabilities of both the platforms for bacteria sensing are presented and compared for strains of Escherichia coli, lipopolysaccharide E. coli, outer membrane proteins of E. coli, and Staphylococcus aureus. While DTP-LPGs have been more explored for bacteria detection in 102–106 Colony Forming Unit (CFU)/mL for S. aureus and 103–109 CFU/mL for E. coli, the µIMZIs reached 102–108 CFU/mL for E. coli and have a potential for becoming picoliter bacteria sensors.

9 February 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
EBEwa Brzozowska
Ewa Brzozowska
MKMarcin Koba
Marcin Koba
Mateusz SmietanaMateusz Smietana
Mateusz Smietana
Sabina GórskaSabina Górska
Sabina Górska
Monika JanikMonika Janik
Monika Janik
WBWojtek J. Bock
Wojtek J. Bock
This paper presents a novel application of a highly sensitive sensor based on long-period gratings (LPGs) coated with T4 bacteriophage adhesin for Gram-negative bacteria detection. We show here, that the sensor evidently recognizes Escherichia coli K-12 (PCM2560), whereas in the reference tests – ELISA and BIAcore – the results are questionable. For LPGs sensor the resonant wavelength shift observed for E. coli K-12 was approximately half of that measured for E.coli B (positive control). The BIAcore readings (RU) for E. coli K-12 were at 10% level of the signal obtained for E .coli B. These results confirm the improved sensitivity of the LPGs sensor. Moreover, we also show that application of adhesin may allow for efficient detection of E. coli O111 (PCM418), Klebsiella pneumoniae O1 (PCM1) and Yersinia enterocolitica O1 (PCM1879). The specificity of binding bacteria by the adhesin is discussed and it is determined by a distinct region of lipopolysaccharide receptors and/or by the presence of outer-membrane protein C in an outer membrane of Gram-negative bacteria.

22 December 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EBEwa Brzozowska
Ewa Brzozowska
APAnna Pyra
Anna Pyra
KPKrzysztof Jakub Pawlik
Krzysztof Jakub Pawlik
Monika JanikMonika Janik
Monika Janik
Sabina GórskaSabina Górska
Sabina Górska
AGAndrzej Gamian
Andrzej Gamian
In this paper, the enzymatic activity, substrate specificity and antibiofilm feature of bacteriophage dual-function tail proteins are presented. So far, tail tubular proteins A–TTPAgp31 and TTPAgp44-have been considered as structural proteins of Klebsiella pneumoniae bacteriophages KP32 and KP34, respectively. Our results show that TTPAgp31 is able to hydrolyze maltose as well as Red-starch. The activity of 1 µM of the protein was calculated as 47.6 milli-Units/assay relating to the α-amylase activity. It degrades capsular polysaccharides (cPS), slime polysaccharides (sPS) and lipopolysaccharide (LPS) of K. pneumoniae PCM 2713 and shows antibiofilm reactivity towards S. aureus PCM 519 and E. faecalis PCM 2673. TTPAgp44 hydrolyses trehalose and cPS of E. faecium PCM 1859. TTPAgp44′s activity was also observed in the antibiofilm test against P. aeruginosa PCM 2710 and B. subtilis PCM 2021. TTPAgp31 has been identified as α-1,4-glucosidase whereas, TTPAgp44 exhibits trehalase-like activity. Both proteins contain aspartate and glutamate residues in the β-stranded region which are essential for catalytic activity of glycoside hydrolases. The significant novelty of our results is that for the first time the bacteriophage tubular proteins are described as the unique enzymes displaying no similarity to any known phage hydrolases. They can be used as antibacterial agents directed against bacterial strains producing exopolysaccharides and forming a biofilm.