Jacqueline Linnes

Dr. Jacqueline Linnes

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
NRNatalia M. Rodriguez
Natalia M. Rodriguez
JLJacqueline Linnes
Jacqueline Linnes
AFAndy Fan
Andy Fan
CECourtney K. Ellenson
Courtney K. Ellenson
NPNira R. Pollock
Nira R. Pollock
CKCatherine Klapperich
Catherine Klapperich

20 September 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
EPElizabeth A. Phillips
Elizabeth A. Phillips
TMTaylor J. Moehling
Taylor J. Moehling
KEKarin F. K. Ejendal
Karin F. K. Ejendal
OHOrlando Hoilett
Orlando Hoilett
KBKristin M. Byers
Kristin M. Byers
JLJacqueline Linnes
Jacqueline Linnes
While identifying acute HIV infection is critical to providing prompt treatment to HIV-positive individuals and preventing transmission, existing laboratory-based testing methods are too complex to perform at the point of care. Specifically, molecular techniques can detect HIV RNA within 8–10 days of transmission but require laboratory infrastructure for cold-chain reagent storage and extensive sample preparation performed by trained personnel. Here, we demonstrate our point-of-care microfluidic rapid and autonomous analysis device (microRAAD) that automatically detects HIV RNA from whole blood. Inside microRAAD, we incorporate vitrified amplification reagents, thermally-actuated valves for fluidic control, and a temperature control circuit for low-power heating. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) products are visualized using a lateral flow immunoassay (LFIA), resulting in an assay limit of detection of 100 HIV-1 RNA copies when performed as a standard tube reaction. Even after three weeks of room-temperature reagent storage, microRAAD automatically isolates the virus from whole blood, amplifies HIV-1 RNA, and transports amplification products to the internal LFIA, detecting as few as 3 × 105 HIV-1 viral particles, or 2.3 × 107 virus copies per mL of whole blood, within 90 minutes. This integrated microRAAD is a low-cost and portable platform to enable automated detection of HIV and other pathogens at the point of care.

18 April 2018 in Analytical Chemistry
Verified
Journal Article
Open access
EPElizabeth A. Phillips
Elizabeth A. Phillips
TMTaylor J. Moehling
Taylor J. Moehling
SBSanchita Bhadra
Sanchita Bhadra
AEAndrew D. Ellington
Andrew D. Ellington
JLJacqueline Linnes
Jacqueline Linnes
Sensitive and specific detection of pathogens via nucleic acid amplification is currently constrained to laboratory settings and portable equipment with costly fluorescent detectors. Nucleic acid-detecting lateral flow immunoassay strips (LFIAs) offer a low-cost visual transduction strategy at points of need. Unfortunately, these LFIAs frequently detect amplification byproducts that can yield spurious results which can only be deciphered through statistical analysis. We integrated customizable strand displacement probes into standard loop mediated isothermal amplification (LAMP) assays to prevent byproduct capture on commercial LFIAs. We find that combining strand displacement with LAMP (SD-LAMP) yields LFIA test band intensities that can be unequivocally interpreted by human subjects without additional instrumentation, thereby alleviating the need for a portable reader’s analysis. Using SD-LAMP, we capture target amplicons on commercially-available LFIAs from as few as 3.5 Vibrio cholerae and 2,750 Escherichia coli bacteria without false positive or false negative interpretation. Moreover, we demonstrate that LFIA capture of SD-LAMP products remain specific even in the presence of complex sample matrices, providing a significant step towards reliable instrument-free pathogen detection outside of laboratories.

23 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
OHOrlando Hoilett
Orlando Hoilett
JWJenna F. Walker
Jenna F. Walker
BBBethany M. Balash
Bethany M. Balash
NJNicholas J. Jaras
Nicholas J. Jaras
SBSriram Boppana
Sriram Boppana
JLJacqueline Linnes
Jacqueline Linnes
The demand for wearable and point-of-care devices has led to an increase in electrochemical sensor development to measure an ever-increasing array of biological molecules. In order to move from the benchtop to truly portable devices, the development of new biosensors requires miniaturized instrumentation capable of making highly sensitive amperometric measurements. To meet this demand, we have developed KickStat, a miniaturized potentiostat that combines the small size of the integrated Texas Instruments LMP91000 potentiostat chip (Texas Instruments, Dallas, TX, USA) with the processing power of the ARM Cortex-M0+ SAMD21 microcontroller (Microchip Technology, Chandler, AZ, USA) on a custom-designed 21.6 mm by 20.3 mm circuit board. By incorporating onboard signal processing via the SAMD21, we achieve 1 mV voltage increment resolution and an instrumental limit of detection of 4.5 nA in a coin-sized form factor. This elegant engineering solution allows for high-resolution electrochemical analysis without requiring extensive circuitry. We measured the faradaic current of an anti-cocaine aptamer using cyclic voltammetry and square wave voltammetry and demonstrated that KickStat’s response was within 0.6% of a high-end benchtop potentiostat. To further support others in electrochemical biosensors development, we have made KickStat’s design and firmware available in an online GitHub repository.

29 August 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
JLJacqueline Linnes
Jacqueline Linnes
AFAndy Fan
Andy Fan
NRNatalia M. Rodriguez
Natalia M. Rodriguez
BLBertrand Lemieux
Bertrand Lemieux
HKHuimin Kong
Huimin Kong
CKCatherine Klapperich
Catherine Klapperich
Herein we show the development of a minimally instrumented paper-based molecular diagnostic for point of care detection of sexually transmitted infections caused by Chlamydia trachomatis. This new diagnostic platform incorporates cell lysis, isothermal nucleic acid amplification, and lateral flow visual detection using only pressure and heat sources, eliminating the need for expensive laboratory equipment. This paper-based test can be performed in less than one hour and has a clinically relevant limit of detection that is 100× more sensitive than current rapid immunoassays used for chlamydia diagnosis.

23 February 2016 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
JLJacqueline Linnes
Jacqueline Linnes
NRN. M. Rodriguez
N. M. Rodriguez
LLL. Liu
L. Liu
CKCatherine Klapperich
Catherine Klapperich