Catherine Klapperich

Dr. Catherine Klapperich


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
RLRose A. Lee
Rose A. Lee
HPHelena De Puig
Helena De Puig
PNPeter Q. Nguyen
Peter Q. Nguyen
NANicolaas M. Angenent-Mari
Nicolaas M. Angenent-Mari
NDNina M. Donghia
Nina M. Donghia
JCJames J. Collins
James J. Collins
Significance: Detection of submicroscopic malaria in asymptomatic individuals is needed for eradication and remains a diagnostic gap in resource-limited settings. Nonfalciparum clinical diagnostics are a second gap, as these infections have a low parasite density and are commonly undetected. We describe an integrated, 60-min, ultrasensitive and specific CRISPR-based diagnostic for the four major pathogenic Plasmodium species that can fill these gaps. Using the SHERLOCK (specific high-sensitivity enzymatic reporter unlocking) platform, we designed assays with limits of detection below that recommended by the World Health Organization. These assays have a simplified sample preparation method: the SHERLOCK parasite rapid extraction protocol, which eliminates complicated nucleic acid extraction steps. Our work further translates the SHERLOCK platform into a field-deployable diagnostic.

20 January 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
NRNatalia M. Rodriguez
Natalia M. Rodriguez
WWWinnie S. Wong
Winnie S. Wong
LLLena Liu
Lena Liu
RDRajan Dewar
Rajan Dewar
CKCatherine Klapperich
Catherine Klapperich
Paper diagnostics have successfully been employed to detect the presence of antigens or small molecules in clinical samples through immunoassays; however, the detection of many disease targets relies on the much higher sensitivity and specificity achieved via nucleic acid amplification tests (NAAT). The steps involved in NAAT have recently begun to be explored in paper matrices, and our group, among others, has reported on paper-based extraction, amplification, and detection of DNA and RNA targets. Here, we integrate these paper-based NAAT steps into a single paperfluidic chip in a modular, foldable system that allows for fully integrated fluidic handling from sample to result. We showcase the functionality of the chip by combining nucleic acid isolation, isothermal amplification, and lateral flow detection of human papillomavirus (HPV) 16 DNA directly from crude cervical specimens in less than 1 hour for rapid, early detection of cervical cancer. The chip is made entirely of paper and adhesive sheets, making it low-cost, portable, and disposable, and offering the potential for a point-of-care molecular diagnostic platform even in remote and resource-limited settings.

15 July 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
NRNatalia M. Rodriguez
Natalia M. Rodriguez
JLJacqueline Linnes
Jacqueline Linnes
AFAndy Fan
Andy Fan
CECourtney K. Ellenson
Courtney K. Ellenson
NPNira R. Pollock
Nira R. Pollock
CKCatherine Klapperich
Catherine Klapperich

29 June 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MMMadhumita Mahalanabis
Madhumita Mahalanabis
HAHussam Al-Muayad
Hussam Al-Muayad
MKM. Dominika Kulinski
M. Dominika Kulinski
DADave Altman
Dave Altman
CKCatherine Klapperich
Catherine Klapperich
Sepsis caused by gram positive and gram negative bacteria is the leading cause of death in noncoronary ICUs and the tenth leading cause of death in the United States. We have developed a microfluidic sample preparation platform for rapid on-chip detection of infectious organisms for point-of-care diagnostics. The microfluidic chips are made of a robust thermoplastic and can be easily multiplexed for high throughput applications. Bacteria are lysed on-chip via hybrid chemical/mechanical method. Once lysed, the bacterial DNA is isolated using a microscale silica bead/polymer composite solid-phase-extraction (SPE) column. Lysis was confirmed using off-chip real time PCR. We isolated and detected both gram-negative (Escherichia coli) and gram-positive (Bacillussubtilis and Enterococcus faecalis) bacterial genomic DNA from microliter scale spiked whole human blood samples. The system performs better for gram-negative bacteria than it does for gram-positive bacteria, with limits of detection at 102CFU/ml and 103–104CFU/ml, respectively. Total extraction times are less than one hour and can be further decreased by altering the channel geometry and pumping configuration.

23 December 2005 in Analytical Chemistry
Verified
Journal Article
Closed access
ABArpita Bhattacharyya
Arpita Bhattacharyya
CKCatherine Klapperich
Catherine Klapperich

5 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CKConstantinos Katevatis
Constantinos Katevatis
AFAndy Fan
Andy Fan
CKCatherine Klapperich
Catherine Klapperich
DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input DNA. Thus, when the input clinical sample contains less than 1 μg of total DNA, the target-specific DNA recovery from most of these protocols is low without supplementing the sample with exogenous carrier DNA. In fact, many clinical samples used in the development of POC diagnostics often exhibit target DNA concentrations as low as 3 ng/mL. With the broader goal of improving the yield and efficiency of nucleic acid-based POC devices for dilute samples, we investigated both DNA adsorption and recovery from silica particles by using 1 pg– 1 μg of DNA with a set of adsorption and elution buffers ranging in pH and chaotropic presence. In terms of adsorption, we found that low pH and the presence of chaotropic guanidinium thiocyanate (GuSCN) enhanced DNA-silica adsorption. When eluting with a standard low-salt, high-pH buffer, > 70% of DNA was unrecoverable, except when DNA was initially adsorbed with 5 M GuSCN at pH 5.2. Unrecovered DNA was either not initially adsorbed or irreversibly bound on the silica surface. Recovery was improved when eluting with 95°C formamide and 1 M NaOH, which suggested that DNA-silica-chaotrope interactions are dominated by hydrophobic interactions and hydrogen bonding. While heated formamide and NaOH are non-ideal elution buffers for practical POC devices, the salient results are important for engineering a set of optimized reagents that could maximize nucleic acid recovery from a microfluidic DNA-silica-chaotrope system.