PURPOSE: To evaluate the ability of a new combined biomechanical index called the Corvis Biomechanical Index (CBI) based on corneal thickness profile and deformation parameters to separate normal from keratoconic patients. METHODS: Six hundred fifty-eight patients (329 eyes in each database) were included in this multicenter retrospective study. Patients from two clinics located on different continents were selected to test the capability of the CBI to separate healthy and keratoconic eyes in more than one ethnic group using the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). Logistic regression was employed to determine, based on Database 1 as the development dataset, the optimal combination of parameters to accurately separate normal from keratoconic eyes. The CBI was subsequently independently validated on Database 2. RESULTS: The CBI included several dynamic corneal response parameters: deformation amplitude ratio at 1 and 2 mm, applanation 1 velocity, standard deviation of deformation amplitude at highest concavity, Ambrósio's Relational Thickness to the horizontal profile, and a novel stiffness parameter. The receiver operating characteristic curve analysis of the training database showed an area under the curve of 0.983. With a cut-off value of 0.5, 98.2% of the cases were correctly classified with 100% specificity and 94.1% sensitivity. In the validation dataset, the same cut-off point correctly classified 98.8% of the cases with 98.4% specificity and 100% sensitivity. CONCLUSIONS: The CBI was shown to be highly sensitive and specific to separate healthy from keratoconic eyes. The presence of an external validation dataset confirms this finding and suggests the possible use of the CBI in everyday clinical practice to aid in the diagnosis of keratoconus. [ J Refract Surg. 2016;32(12):803–810.]

1 March 2009 in Ophthalmology
Verified
Journal Article
Closed access
PVPaolo Vinciguerra
Paolo Vinciguerra
EAElena Albè
Elena Albè
STSilvia Trazza
Silvia Trazza
PRPietro Rosetta
Pietro Rosetta
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
DEDan Epstein
Dan Epstein

1 August 2016 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
CRCynthia J. Roberts
Cynthia J. Roberts
RARenato Ambrósio
Renato Ambrósio
DKDavid Sung Yong Kang
David Sung Yong Kang
PVPaolo Vinciguerra
Paolo Vinciguerra
PURPOSE: To evaluate the influence of pachymetry, age, and intraocular pressure in normal patients and to provide normative values for all dynamic corneal response parameters (DCRs) provided by dynamic Scheimpflug analysis. METHODS: Seven hundred five healthy patients were included in this multicenter retrospective study. The biomechanical response data were analyzed to obtain normative values with their dependence on corrected and clinically validated intraocular pressure estimates developed using the finite element method (bIOP), central corneal thickness (CCT), and age, and to evaluate the influence of bIOP, CCT, and age. RESULTS: The results showed that all DCRs were correlated with bIOP except deflection amplitude (DefA) ratio, highest concavity (HC) radius, and inverse concave radius. The analysis of the relationship of DCRs with CCT indicated that HC radius, inverse concave radius, deformation amplitude (DA) ratio, and DefA ratio were correlated with CCT (rho values of 0.343, −0.407, −0.444, and −0.406, respectively). The age group subanalysis revealed that primarily whole eye movement followed by DA ratio and inverse concave radius were the parameters that were most influenced by age. Finally, custom software was created to compare normative values to imported examinations. CONCLUSIONS: HC radius, inverse concave radius, DA ratio, and DefA ratio were shown to be suitable parameters to evaluate in vivo corneal biomechanics due to their independence from IOP and their correlation with pachymetry and age. The creation of normative values allows the interpretation of an abnormal examination without the need to match every case with another normal patient matched for CCT and IOP. [ J Refract Surg . 2016;32(8):550–561.]

1 September 2012 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
PVPaolo Vinciguerra
Paolo Vinciguerra
EAElena Albé
Elena Albé
BFBeatrice E. Frueh
Beatrice E. Frueh
STSilvia Trazza
Silvia Trazza
DEDaniel Epstein
Daniel Epstein

12 October 2009 in Archives of Ophthalmology (1950)
Verified
Journal Article
Open access
PDF file
PVPaolo Vinciguerra
Paolo Vinciguerra
EAElena Albè
Elena Albè
STSilvia Trazza
Silvia Trazza
TSTheo Seiler
Theo Seiler
DEDaniel Epstein
Daniel Epstein
A new treatment, UV corneal collagen cross-linking (CXL), has been recently introduced to reduce the progression of noninflammatory corneal degeneration such as keratoconus, pellucid marginal degeneration, and ectatic corneal disorders after corneal refractive procedures.1-3 The treatment consists of CXL by the photosensitizer riboflavin and UV-A light preceded by corneal epithelial removal.4

1 May 2013 in Ophthalmology
Verified
Journal Article
Closed access
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
MRMario R. Romano
Mario R. Romano
FCFabrizio I. Camesasca
Fabrizio I. Camesasca
CAClaudio Azzolini
Claudio Azzolini
STSilvia Trazza
Silvia Trazza
PVPaolo Vinciguerra
Paolo Vinciguerra