Christian Fabry

Mr. Christian Fabry


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
CFChristian Fabry
Christian Fabry
JLJean Langlois
Jean Langlois
MHMoussa Hamadouche
Moussa Hamadouche
RBRainer Bader
Rainer Bader

1 September 2012 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CFChristian Fabry
Christian Fabry
SHSven Herrmann
Sven Herrmann
MKMichael Kaehler
Michael Kaehler
EKErnst-Dieter Klinkenberg
Ernst-Dieter Klinkenberg
CWChristoph Woernle
Christoph Woernle
RBRainer Bader
Rainer Bader
At present, wear investigations of total hip replacements are performed in accordance with the ISO standard 14242, which is based on simplified kinematic and force data of the gait cycle. The aim of this analytical study was to generate parameter sets of daily life activities in order to replicate more realistic joint load situations in wear testing. Hence, published in vivo motion and force data of daily life activities were evaluated and adjusted using analytical techniques. The created kinematically and dynamically consistent parameter sets comprised time trajectories of three Cardan angles to describe the motion of the femur with respect to the pelvis and time trajectories of three force components, representing the hip joint contact force. The parameter sets include the activities of walking, knee bending, stair climbing and a combined load case of sitting down and standing up. Additionally, a motion sequence following the frequency of daily life activities was presented. Differences of the evaluated angular motions and joint contact forces in comparison to the ISO standard 14242-1 were pointed out. The results of this study offer the possibility to extend the kinematics and dynamics of the ISO standard test protocol and to support the loading conditions of hip wear simulators with a comprehensive set of motions and loads close to reality.

20 May 2017 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
CFChristian Fabry
Christian Fabry
CZCarmen Zietz
Carmen Zietz
ABAxel Baumann
Axel Baumann
REReinhard Ehall
Reinhard Ehall
RBRainer Bader
Rainer Bader
Purpose The objective of this study was to evaluate the in vivo wear resistance of cobalt-chromium femoral components coated with titanium nitride (TiN). Our null hypothesis was that the surface damage and the thickness of the TiN coating do not correlate with the time in vivo. Methods Twenty-five TiN-coated bicondylar femoral retrievals with a mean implantation period of 30.7 ± 11.7 months were subjected to an objective surface damage analysis with a semi-quantitative assessment method. A visual examination of scratches, indentations, notches and coating breakthroughs of the surfaces was performed. The roughness and the coating thickness of the TiN coating were evaluated in the main articulation regions. Results Narrow scratches and indentations in the range of low flexion angles on the retrieval surfaces were the most common modes of damage. There was no evidence of delamination on the articulation surface but rather at the bottom of isolated severe indentations or notches. An analysis of three retrievals revealed a coating breakthrough in the patellofemoral joint region, resulting from patella maltracking and a dislocation. The arithmetical mean roughness of the TiN surface slightly increased with the implantation period. In contrast, the maximum peak height of the roughness profile was reduced at the condyles of the retrieved components in comparison with new, unused surfaces. No significant association between the coating thickness and implantation period was determined. Moreover, the measured values were retained in the range of the initial coating thickness even after several years of in vivo service. Conclusions As was demonstrated by the results of this study, the surface damage to the TiN coating did not deteriorate with the implantation period. The calculated damage scores and the measured coating thickness in particular both confirmed that the TiN coating provides low wear rates. Our findings support the use of wear-resistant TiN-coated components in total knee arthroplasty with the objective of reducing the risk of aseptic loosening. However, in terms of TiN-coated femoral components, particular attention should be paid to a correct patellar tracking in order to avoid wear propagation at the implant.

24 October 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CFChristian Fabry
Christian Fabry
MKMichael Kaehler
Michael Kaehler
SHSven Herrmann
Sven Herrmann
CWChristoph Woernle
Christoph Woernle
RBRainer Bader
Rainer Bader
Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs.

16 February 2015 in Lubricants
Verified
Journal Article
Open access
PDF file
CFChristian Fabry
Christian Fabry
CZCarmen Zietz
Carmen Zietz
ABAxel Baumann
Axel Baumann
RBRainer Bader
Rainer Bader
The aim of the present study was to evaluate the biotribology of current surface modifications on femoral heads in terms of wettability, polyethylene wear and ion-release behavior. Three 36 mm diameter ion-treated CoCr heads and three 36 mm diameter TiNbN-coated CoCr heads were articulated against sequentially cross-linked polyethylene inserts (X3) in a hip joint simulator, according to ISO 14242. Within the scope of the study, the cobalt ion release in the lubricant, as well as contact angles at the bearing surfaces, were investigated and compared to 36 mm alumina ceramic femoral heads over a period of 5 million cycles. The mean volumetric wear rates were 2.15 ± 0.18 mm3·million cycles−1 in articulation against the ion-treated CoCr head, 2.66 ± 0.40 mm3·million cycles−1 for the coupling with the TiNbN-coated heads and 2.17 ± 0.40 mm3·million cycles−1 for the ceramic heads. The TiNbN-coated femoral heads showed a better wettability and a lower ion level in comparison to the ion-treated CoCr heads. Consequently, the low volumes of wear debris, which is comparable to ceramics, and the low concentration of metal ions in the lubrication justifies the use of coated femoral heads.

9 April 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
CFChristian Fabry
Christian Fabry
CWChristoph Woernle
Christoph Woernle
RBRainer Bader
Rainer Bader
The increased jump distance against dislocation and the large range of motion due to the enlarged effective head diameter substantiate the use of dual-mobility systems in cases of total hip joint instability. For this type of total hip endoprostheses, an eccentric design of the outer bearing is assumed in order to provide a force-dependent self-centering mechanism and an improved joint stability against dislocation. The purpose of this study was to determine the relative movements and realignment of different intermediate components during various motion cycles as a result of the eccentric design. We established a validated mathematical model for eccentric dual-mobility systems, which allowed a comparison of relative movements, self-centering torque and overall frictional torque during four different activities in order to analyze their motion behavior in everyday life. In addition, the impact of different radial clearances on the dynamic performance of the self-centering mechanism was investigated. According to torque patterns and the validation experiment, the main articulation of eccentric dual-mobility systems was limited to the smaller inner bearing for the most daily life activities, i.e. the eccentric intermediate component remained in its current position and only with changing activity did the intermediate component realign clearly. However, an inappropriate dimensioning of the radial clearance could lead to a permanent realignment of the intermediate component during the motion cycles. In general, the self-centering mechanism of the intermediate component seems to have no negative influence on relative movements and wear propagation of dual-mobility cup systems if the clearance and eccentricity are appropriately dimensioned.