Wenliang Chen

Dr. Wenliang Chen


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Foods
Verified
Journal Article
Open access
PDF file
YYYuewen Yu
Yuewen Yu
WCWenliang Chen
Wenliang Chen
HZHanwen Zhang
Hanwen Zhang
RLRong Liu
Rong Liu
CLChenxi Li
Chenxi Li
The detection of the storage state of frozen meat, especially meat frozen–thawed several times, has always been important for food safety inspections. Hyperspectral imaging (HSI) is widely applied to detect the freshness and quality of meat or meat products. This study investigated the feasibility of the low-cost HSI system, combined with the chemometrics method, to classify beef cuts among fresh (F), frozen–stored (F–S), frozen–thawed three times (F–T–3) and frozen–thawed five times (F–T–5). A compact, low-cost HSI system was designed and calibrated for beef sample measurement. The classification model was developed for meat analysis with a method to distinguish fat and muscle, a CARS algorithm to extract the optimal wavelength subset and three classifiers to identify each beef cut among different freezing processes. The results demonstrated that classification models based on feature variables extracted from differentiated tissue spectra achieved better performances, with ACCs of 92.75% for PLS-DA, 97.83% for SVM and 95.03% for BP-ANN. A visualization map was proposed to provide detailed information about the changes in freshness of beef cuts after freeze–thawing. Furthermore, this study demonstrated the potential of implementing a reasonably priced HSI system in the food industry.

7 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenbo Liu
Wenbo Liu
THTongshuai Han
Tongshuai Han
WCWenliang Chen
Wenliang Chen
JCJiayu Chen
Jiayu Chen
QGQing Ge
Qing Ge
KXKexin Xu
Kexin Xu
Optical sensors serve as pivotal components in the realm of non-invasive blood glucose measurement (NBGM) devices, where their efficacy directly influences the detection of weak glucose signals. This research introduces three fundamental design key points tailored for diffuse reflectance optical sensors employed for NBGM: depth resolution, detection signal-to-noise ratio, and human–sensor interface coupling. Guided by these design key points, we presented feasible design proposals for near-infrared diffuse reflectance sensors operating in the range of 1000–1700 nm. As an example, a sensor composed of five-ring detectors with a ring-shaped mask were made and tested on human skin. The innovative sensor developed herein holds promising potential for NBGM.

1 January 2023 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
ZNZhao Nianfu
Zhao Nianfu
WLWang Lin
Wang Lin
WXWang Xiangjun
Wang Xiangjun
WCWenliang Chen
Wenliang Chen
天津天津大学精密测试技术及仪器国家重点实验室,天津300072
天津大学精密测试技术及仪器国家重点实验室,天津300072
天津天津大学微光机电系统技术教育部重点实验室,天津300072
天津大学微光机电系统技术教育部重点实验室,天津300072
In order to build a re-detection module suitable for long-term tracking, inspired by the GlobalTrack method which improves two-stage detection network, an efficient deep network for end-to-end re-detection of specific template targets was proposed. First, for more efficient fusion of template features on large-scale images, the depth-wise correlation method was improved by constructing a cross-information enhancement module, which encoded the information of search and template features with cross channel-attention information. In addition, the region proposal network (RPN) and region-based convolutional neural networks (RCNN) structure of traditional two-stage detection network were replaced with a dynamic instance interaction module, guiding the classification-and-regression stage of the detection network with template information as well as building an end-to-end sparse re-detection structure. Comparing results on LaSOT and OxUva long-term tracking datasets, the performance of proposed method is improved by 3%, and the real-time frame rate is improved by 173% compared with those of the original method. The experimental results show that the improved method can re-detect template targets more accurately and quickly in the whole image range.