Qing Ge

Dr. Qing Ge

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
QGQing Ge
Qing Ge
THTongshuai Han
Tongshuai Han
RLRong Liu
Rong Liu
ZZZengfu Zhang
Zengfu Zhang
DSDi Sun
Di Sun
KXKexin Xu
Kexin Xu
In non-invasive blood glucose measurement, the sensitivity of glucose-induced optical signals within human tissue is a crucial reference point. This study evaluates the sensitivity of glucose-induced diffuse reflectance in the 1000–1700 nm range. A key factor in understanding this sensitivity is the rate at which the scattering coefficient changes due to glucose, as it is significantly higher than in non-living media and predominantly influences the diffuse light signal level when blood glucose levels change. The study measured and calculated the changes in the scattering coefficient at 1314 nm, a wavelength chosen for its minimal interference from glucose absorption and other bodily constituents. Based on the Mie scattering theory and the results at 1314 nm, the changes in the scattering coefficient within the 1000–1700 nm range were estimated. Subsequently, the sensitivity of the glucose signal across this range was determined through Monte Carlo (MC) simulations. The findings from 25 human trials indicate that the measured sensitivities at five other typical wavelengths within this band generally align with the sensitivities calculated using the aforementioned method. This research can guide the identification of blood glucose signals and the selection of wavelengths for non-invasive blood glucose measurements.

14 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
QGQing Ge
Qing Ge
THTongshuai Han
Tongshuai Han
XLXueying Liu
Xueying Liu
JCJiayu Chen
Jiayu Chen
WLWenbo Liu
Wenbo Liu
KXKexin Xu
Kexin Xu
In non-invasive blood glucose measurement (NBGM) based on near-infrared spectroscopy, fluctuations in blood flow represent a primary source of interference. This paper proposes a local blood flow pre-stimulation method in which the local skin is heated to dilate blood vessels and increase blood flow. This approach aims to mitigate the impact of environmental temperature variations, emotional fluctuations, and insulin secretion on blood flow, thereby enhancing the accuracy of glucose measurement. To evaluate the effectiveness of this method, a blood flow interference experiment was conducted to compare the stability of the measured spectra with and without blood flow pre-stimulation. The results demonstrated that the pre-stimulation method presents good anti-interference capabilities. Furthermore, 45 volunteers underwent oral glucose tolerance tests (OGTTs) as a part of the validation experiments. In these tests, the forearm skin blood flow of 24 volunteers was pre-stimulated using elevated temperature, while the skin of the remaining 21 subjects was maintained at a natural temperature level without stimulation. The results indicate that compared to the non-stimulated condition, the correlation between the optical signal at 1550 nm and blood glucose levels was significantly enhanced under the pre-stimulation condition. Furthermore, the root mean square error (RMSE) of the linear prediction model was reduced to just 0.92 mmol/L. In summary, this paper presents a feasible blood flow control strategy that effectively stabilizes internal blood flow, thereby improving the accuracy of NBGM.

7 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenbo Liu
Wenbo Liu
THTongshuai Han
Tongshuai Han
WCWenliang Chen
Wenliang Chen
JCJiayu Chen
Jiayu Chen
QGQing Ge
Qing Ge
KXKexin Xu
Kexin Xu
Optical sensors serve as pivotal components in the realm of non-invasive blood glucose measurement (NBGM) devices, where their efficacy directly influences the detection of weak glucose signals. This research introduces three fundamental design key points tailored for diffuse reflectance optical sensors employed for NBGM: depth resolution, detection signal-to-noise ratio, and human–sensor interface coupling. Guided by these design key points, we presented feasible design proposals for near-infrared diffuse reflectance sensors operating in the range of 1000–1700 nm. As an example, a sensor composed of five-ring detectors with a ring-shaped mask were made and tested on human skin. The innovative sensor developed herein holds promising potential for NBGM.