The relative motion between human and exoskeleton is a crucial factor that has remarkable consequences on the efficiency, reliability and safety of human-robot interaction. Unfortunately, its quantitative assessment has been largely overlooked in the literature. Here, we present a methodology that allows predicting the motion of the human joints from the knowledge of the angular motion of the exoskeleton frame. Our method combines a subject-specific skeletal model with a kinematic model of a lower limb exoskeleton (H2, Technaid), imposing specific kinematic constraints between them. To calibrate the model and validate its ability to predict the relative motion in a subject-specific way, we performed experiments on seven healthy subjects during treadmill walking tasks. We demonstrate a prediction accuracy lower than 3.5° globally, and around 1.5° at the hip level, which represent an improvement up to 66% compared to the traditional approach assuming no relative motion between the user and the exoskeleton.
23 January 2022 in The International Journal of Advanced Manufacturing Technology
The generation of the printing paths is a decisive step in additive manufacturing (AM). There is a variety of patterns that offer different characteristics, but those that are strictly continuous become especially relevant in certain types of AM by extrusion, with materials like bioinks, carbon or clays, since they do not allow the retraction of the material and travelling movements result in the generation of artifacts. In this work, we present (1) a method that generates continuous paths to fill 2D polygons with a hybrid zig-zag and contour pattern with any direction and line separation, which extends an algorithm that decomposes the 2D area to be filled into convex areas, overcoming its limitations to generate less subpolygons in certain cases, (2) a method to join the subpolygon trajectories such that a continuous path that fills the whole polygon is obtained, and (3) a publicly available dataset containing (a) a set of 2D polygons that are relevant to test the performance of the algorithms and (b) the results of filling those polygons with our methodology. Results show that the developed methods produce satisfactory results for the polygons contained in the evaluation dataset, including a couple of demonstrations of real 3D prints with the generated trajectories. Further work is needed to extend the methodology to produce suitable solutions for polygons with curved holes.
New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation.
Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types.
14 September 2018 in Healthcare Technology Letters
StereoElectroEncephaloGraphy (SEEG) is a minimally invasive technique that consists of the insertion of multiple intracranial electrodes to precisely identify the epileptogenic focus. The planning of electrode trajectories is a cumbersome and time‐consuming task. Current approaches to support the planning focus on electrode trajectory optimisation based on geometrical constraints but are not helpful to produce an initial electrode set to begin with the planning procedure. In this work, the authors propose a methodology that analyses retrospective planning data and builds a set of average trajectories, representing the practice of a clinical centre, which can be mapped to a new patient to initialise planning procedure. They collected and analysed the data from 75 anonymised patients, obtaining 30 exploratory patterns and 61 mean trajectories in an average brain space. A preliminary validation on a test set showed that they were able to correctly map 90% of those trajectories and, after optimisation, they have comparable or better values than manual trajectories in terms of distance from vessels and insertion angle. Finally, by detecting and analysing similar plans, they were able to identify eight planning strategies, which represent the main tailored sets of trajectories that neurosurgeons used to deal with the different patient cases.
1 November 2019 in Frontiers in Bioengineering and Biotechnology
An abdominal aortic aneurysm (AAA) is a focal dilation of the abdominal aorta, that if not treated, tends to grow and may rupture. The most common treatment for AAAs is the endovascular aneurysm repair (EVAR), which requires that patients undergo Computed Tomography Angiography (CTA)-based post-operative lifelong surveillance due to the possible appearance of complications. These complications may again lead to AAA dilation and rupture. However, there is a lack of advanced quantitative image-analysis tools to support the clinicians in the follow-up. Currently, the approach is to evaluate AAA diameter changes along time to infer the progress of the patient and the post-operative risk of AAA rupture. An increased AAA diameter is usually associated with a higher rupture risk, but there are some small AAAs that rupture, whereas other larger aneurysms remain stable. This means that the diameter-based rupture risk assessment is not suitable for all the cases, and there is increasing evidence that the biomechanical behavior of the AAA may provide additional valuable information regarding the progression of the disease and the risk of rupture. Hence, we propose a promising methodology for post-operative CTA time-series registration and subsequent aneurysm biomechanical strain analysis. From these strains, quantitative image-based descriptors are extracted using a principal component analysis of the tensile and compressive strain fields. Evaluated on 22 patients, our approach yields a mean area under the curve of 88.6% when correlating the strain-based quantitative descriptors with the long-term patient prognosis. This suggests that the strain information directly extracted from the CTA images is able to capture the biomechanical behavior of the aneurysm without relying on finite element modeling and simulation. Furthermore, the extracted descriptors set the basis for possible future imaging biomarkers that may be used in clinical practice. Apart from the diameter, these biomarkers may be used to assess patient prognosis and to enable informed decision making after an EVAR intervention, especially in difficult uncertain cases.