Tomasz Kupka

Tomasz Kupka


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
JJJanusz Jezewski
Janusz Jezewski
AMAdam Matonia
Adam Matonia
TKTomasz Kupka
Tomasz Kupka
DRDawid Roj
Dawid Roj
RCRobert Czabanski
Robert Czabanski
The main aim of our work was to assess the reliability of indirect abdominal electrocardiography as an alternative to the commonly used Doppler ultrasound monitoring technique. As a reference method, we used direct fetal electrocardiography. Direct and abdominal signals were acquired simultaneously, using dedicated instrumentation. The developed method of maternal signal suppression as well as fetal QRS complexes detection was presented. Recordings were collected during established labors, each consisted of four signals from the maternal abdomen and the reference signal acquired directly from the fetal head. After assessing the performance of the QRS detector, the accuracy of fetal heart rate measurement was evaluated. Additionally, to reduce the influence of inaccurately detected R-waves, some validation rules were proposed. The obtained results revealed that the indirect method is able to provide an accuracy sufficient for a reliable assessment of fetal heart rate variability. However, the method is very sensitive to recording conditions, influencing the quality of signals. Our investigations confirmed that abdominal electrocardiography, even in its current stage of development, offers an accuracy equal to or higher than an ultrasound method, at the same time providing some additional features.

25 June 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
AMAdam Matonia
Adam Matonia
JJJanusz Jezewski
Janusz Jezewski
TKTomasz Kupka
Tomasz Kupka
MJMichał Jezewski
Michał Jezewski
KHKrzysztof Horoba
Krzysztof Horoba
RKRadana Kahankova
Radana Kahankova
Monitoring fetal heart rate (FHR) variability plays a fundamental role in fetal state assessment. Reliable FHR signal can be obtained from an invasive direct fetal electrocardiogram (FECG), but this is limited to labour. Alternative abdominal (indirect) FECG signals can be recorded during pregnancy and labour. Quality, however, is much lower and the maternal heart and uterine contractions provide sources of interference. Here, we present ten twenty-minute pregnancy signals and 12 five-minute labour signals. Abdominal FECG and reference direct FECG were recorded simultaneously during labour. Reference pregnancy signal data came from an automated detector and were corrected by clinical experts. The resulting dataset exhibits a large variety of interferences and clinically significant FHR patterns. We thus provide the scientific community with access to bioelectrical fetal heart activity signals that may enable the development of new methods for FECG signals analysis, and may ultimately advance the use and accuracy of abdominal electrocardiography methods.

30 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RCRobert Czabanski
Robert Czabanski
KHKrzysztof Horoba
Krzysztof Horoba
JWJanusz Wrobel
Janusz Wrobel
AMAdam Matonia
Adam Matonia
Radek MartinekRadek Martinek
Radek Martinek
JLJacek M. Leski
Jacek M. Leski
Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.

1 March 2010 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MKM. Kotas
M. Kotas
JJJanusz Jezewski
Janusz Jezewski
AMA. Matonia
A. Matonia
TKTomasz Kupka
Tomasz Kupka

12 April 2006 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
AMAdam Matonia
Adam Matonia
JJJanusz Jezewski
Janusz Jezewski
TKTomasz Kupka
Tomasz Kupka
KHKrzysztof Horoba
Krzysztof Horoba
JWJanusz Wrobel
Janusz Wrobel
AGAdam Gacek
Adam Gacek

16 May 2017 in Frontiers in Physiology
Verified
Journal Article
Open access
JJJanusz Jezewski
Janusz Jezewski
JWJanusz Wrobel
Janusz Wrobel
AMAdam Matonia
Adam Matonia
KHKrzysztof Horoba
Krzysztof Horoba
Radek MartinekRadek Martinek
Radek Martinek
MJMichal Jezewski
Michal Jezewski
Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically – through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy – short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 minutes duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one – by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10% and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis.