Oscar Danilo Montoya Giraldo

Dr. Oscar Danilo Montoya Giraldo

Proyecto curricular de ingeniería eléctrica, Universidad Distrital Francisco Jose de Caldas, Bogotá, Colombia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Energy Storage
Verified
Journal Article
Closed access
Walter Julián Gil-GonzálezWalter Julián Gil-González
Walter Julián Gil-González
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
EHErika Holguín
Erika Holguín
AGAlejandro Garces
Alejandro Garces
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña

1 October 2018 in Electric Power Systems Research
Verified
Journal Article
Closed access
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
DMDaniel Gonzalez Montoya
Daniel Gonzalez Montoya
CRC.A. Ramos-Paja
C.A. Ramos-Paja
AGAlejandro Garces
Alejandro Garces

1 October 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
Walter Julián Gil-GonzálezWalter Julián Gil-González
Walter Julián Gil-González

11 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Walter Julián Gil-GonzálezWalter Julián Gil-González
Walter Julián Gil-González
Alejandro GarcesAlejandro Garces
Alejandro Garces
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
The optimal placement and sizing of distributed generators is a classical problem in power distribution networks that is usually solved using heuristic algorithms due to its high complexity. This paper proposes a different approach based on a mixed-integer second-order cone programming (MI-SOCP) model that ensures the global optimum of the relaxed optimization model. Second-order cone programming (SOCP) has demonstrated to be an efficient alternative to cope with the non-convexity of the power flow equations in power distribution networks. Of relatively new interest to the power systems community is the extension to MI-SOCP models. The proposed model is an approximation. However, numerical validations in the IEEE 33-bus and IEEE 69-bus test systems for unity and variable power factor confirm that the proposed MI-SOCP finds the best solutions reported in the literature. Being an exact technique, the proposed model allows minimum processing times and zero standard deviation, i.e., the same optimum is guaranteed at each time that the MI-SOCP model is solved (a significant advantage in comparison to metaheuristics). Additionally, load and photovoltaic generation curves for the IEEE 69-node test system are included to demonstrate the applicability of the proposed MI-SOCP to solve the problem of the optimal location and sizing of renewable generators using the multi-period optimal power flow formulation. Therefore, the proposed MI-SOCP also guarantees the global optimum finding, in contrast to local solutions achieved with mixed-integer nonlinear programming solvers available in the GAMS optimization software. All the simulations were carried out via MATLAB software with the CVX package and Gurobi solver.

9 January 2019 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
VGVíctor Manuel Garrido-Arévalo
Víctor Manuel Garrido-Arévalo
Walter Julián Gil-GonzálezWalter Julián Gil-González
Walter Julián Gil-González
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
This express brief proposes two new iterative approaches for solving the power flow problem in direct current (DC) networks as efficient alternatives to the classical Gauss–Seidel and Newton–Raphson methods. The first approach works with the set of nonlinear equations by rearranging them into a conventional fixed point form, generating a successive approximation methodology. The second approach is based on Taylors series expansion method by using a set of decoupling equations to linearize the problem around the desired operating point; these linearized equations are recursively solved until reach the solution of the power flow problem with minimum error. These two approaches are comparable to the classical Gauss–Seidel method and the classical Newton–Raphson method, respectively. Simulation results show that the proposed approaches have a better performance in terms of solution precision and computational requirements. All the simulations were conducted via MATLAB software by using its programming interface.

17 June 2021 in Electronics
Verified
Journal Article
Open access
PDF file
CPCristian Mateo Castiblanco Pérez
Cristian Mateo Castiblanco Pérez
DTDavid Esteban Toro-Rodríguez
David Esteban Toro-Rodríguez
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
DGDiego Giral
Diego Giral
In this paper, we propose a new discrete-continuous codification of the Chu–Beasley genetic algorithm to address the optimal placement and sizing problem of the distribution static compensators (D-STATCOM) in electrical distribution grids. The discrete part of the codification determines the nodes where D-STATCOM will be installed. The continuous part of the codification regulates their sizes. The objective function considered in this study is the minimization of the annual operative costs regarding energy losses and installation investments in D-STATCOM. This objective function is subject to the classical power balance constraints and devices’ capabilities. The proposed discrete-continuous version of the genetic algorithm solves the mixed-integer non-linear programming model that the classical power balance generates. Numerical validations in the 33 test feeder with radial and meshed configurations show that the proposed approach effectively minimizes the annual operating costs of the grid. In addition, the GAMS software compares the results of the proposed optimization method, which allows demonstrating its efficiency and robustness.