Jesús C. Hernández

Dr. Jesús C. Hernández

Electrical Engineering department, University of Jaen, Campus Las Lagunillas, s/n, 23071, Jaen, Spain
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Electric Power Systems Research
Verified
Journal Article
Closed access
F. J. Ruiz-RodriguezF. J. Ruiz-Rodriguez
F. J. Ruiz-Rodriguez
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
Francisco JuradoFrancisco Jurado
Francisco Jurado



1 September 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
F. Sánchez-SutilF. Sánchez-Sutil
F. Sánchez-Sutil
PVP.G. Vidal
P.G. Vidal
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas

30 January 2017 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
PBPedro G. Bueno
Pedro G. Bueno
F. Sánchez-SutilF. Sánchez-Sutil
F. Sánchez-Sutil
This research presents a model of a utility‐scale photovoltaic unit (USPVU) enhanced with an embedded hybrid energy storage system (HESS), suitable for stability studies in transmission systems. The main goal of this model is the simultaneous provision of primary frequency control and dynamic grid support. The primary frequency control includes both droop response (achieved by the frequency sensitive mode [FSM] operation) and inertial response (IR). To obtain these grid support functions, the research designed a suitable voltage and frequency ( V – f ) control, which coordinates the photovoltaic (PV) maximum power point tracking control, HESS converter control, and PV inverter control. Firstly, a midterm assessment of energy requirements in the sized HESS, based on frequency data, validated the energy availability of the enhanced USPVU for primary frequency control, according to new prequalification rules for energy‐constrained units. Then, transient stability assessments were performed on a representative transmission system to check the performance of the added FSM and IR in USPVUs with dynamic grid support. The results of the frequency phenomena in the IEEE 39‐bus system showed that the enhanced USPVU shared primary frequency control responsibilities with the conventional generation. This was achieved with two criteria to dispatch and commit conventional units by USPVUs.

1 May 2016 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
PBPedro G. Bueno
Pedro G. Bueno
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
F. J. Ruiz-RodriguezF. J. Ruiz-Rodriguez
F. J. Ruiz-Rodriguez
Photovoltaic (PV) systems are gradually replacing conventional synchronous generators. However, reduced system inertia and lack of dynamic grid support from PV are the main issues that could have a detrimental impact on the transient response in power systems when critical contingencies arise. In this study, the authors modelled and analysed transient and small‐signal stability for a representative transmission system with realistic loading scenarios and high PV penetration levels. First, system eigenvalues were calculated to identify critical modes. Thereafter, the results of the small‐signal analysis were further expanded by performing transient simulations after critical contingencies. Such contingencies detrimentally excited the critical modes of the system. To carry out this analysis, they implemented a positive‐sequence dynamic model of a utility‐scale PV unit (USPVU) in the open programming environment MATLAB/Simulink. This dynamic model is based on a Western Electricity Coordinating Council (WECC) generic model (full converter model), which is suitable for electromechanical transient studies. Also included was the model of the PV array, dc–dc converter, and associated control systems. The most critical factors pertaining to the detrimental or beneficial impact of USPVUs on stability were the unit commitment and dispatch strategy and the protection/control strategy during voltage swell and dip events for equivalent PV penetration and loading scenarios.