Sang Bum Hong

Sang Bum Hong


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2014 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SJSung-Chan Jang
Sung-Chan Jang
SHSang Bum Hong
Sang Bum Hong
HYHee-Man Yang
Hee-Man Yang
KLKune-Woo Lee
Kune-Woo Lee
JMJei-Kwon Moon
Jei-Kwon Moon
Changhyun RohChanghyun Roh
Changhyun Roh
Radioactive cesium (137Cs) has inevitably become a human concern due to exposure from nuclear power plants and nuclear accident releases. Many efforts have been focused on removing cesium and the remediation of the contaminated environment. In this study, we elucidated the ability of Prussian blue-coated magnetic nanoparticles to eliminate cesium from radioactive contaminated waste. Thus, the obtained Prussian blue-coated magnetic nanoparticles were then characterized and examined for their physical and radioactive cesium adsorption properties. This Prussian blue-coated magnetic nanoparticle-based cesium magnetic sorbent can offer great potential for use in in situ remediation.

1 January 2019 in Journal of Korean Medical Science
Verified
Journal Article
Open access
Kyeongman JeonKyeongman Jeon
Kyeongman Jeon
JSJae Kyung Suh
Jae Kyung Suh
EJEun Jin Jang
Eun Jin Jang
SCSonghee Cho
Songhee Cho
HRHo-Geol Ryu
Ho-Geol Ryu
SLSang Min Lee
Sang Min Lee
Jeon K, et al. J Korean Med Sci. 2019 Mar;34(14):e110. https://doi.org/10.3346/jkms.2019.34.e110

28 October 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
HKHara Kang
Hara Kang
SMsujung min
sujung min
BSBumkyung Seo
Bumkyung Seo
Changhyun RohChanghyun Roh
Changhyun Roh
SHSang Bum Hong
Sang Bum Hong
JCJae Hak Cheong
Jae Hak Cheong
The detection and monitoring systems of low energy beta particles are of important concern in nuclear facilities and decommissioning sites. Generally, low-energy beta-rays have been measured in systems such as liquid scintillation counters and gas proportional counters but time is required for pretreatment and sampling, and ultimately it is difficult to obtain a representation of the observables. The risk of external exposure for low energy beta-ray emitting radioisotopes has not been significantly considered due to the low transmittance of the isotopes, whereas radiation protection against internal exposure is necessary because it can cause radiation hazard to into the body through ingestion and inhalation. In this review, research to produce various types of detectors and to measure low-energy beta-rays by using or manufacturing plastic scintillators such as commercial plastic and optic fiber is discussed. Furthermore, the state-of-the-art beta particle detectors using plastic scintillators and other types of beta-ray counters were elucidated with regard to characteristics of low energy beta-ray emitting radioisotopes. Recent rapid advances in organic matter and nanotechnology have brought attention to scintillators combining plastics and nanomaterials for all types of radiation detection. Herein, we provide an in-depth review on low energy beta emitter measurement.

17 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
SMsujung min
sujung min
HKHara Kang
Hara Kang
BSBumkyung Seo
Bumkyung Seo
JCJae Hak Cheong
Jae Hak Cheong
Changhyun RohChanghyun Roh
Changhyun Roh
SHSang Bum Hong
Sang Bum Hong
Recently, nanomaterial-based scintillators are newly emerging technologies for many research fields, including medical imaging, nuclear security, nuclear decommissioning, and astronomical applications, among others. To date, scintillators have played pivotal roles in the development of modern science and technology. Among them, plastic scintillators have a low atomic number and are mainly used for beta-ray measurements owing to their low density, but these types of scintillators can be manufactured not in large sizes but also in various forms with distinct properties and characteristics. However, the plastic scintillator is mainly composed of C, H, O and N, implying that the probability of a photoelectric effect is low. In a gamma-ray nuclide analysis, they are used for time-related measurements given their short luminescence decay times. Generally, inorganic scintillators have relatively good scintillation efficiency rates and resolutions. And there are thus widely used in gamma-ray spectroscopy. Therefore, developing a plastic scintillator with performance capabilities similar to those of an inorganic scintillator would mean that it could be used for detection and monitoring at radiological sites. Many studies have reported improved performance outcomes of plastic scintillators based on nanomaterials, exhibiting high-performance plastic scintillators or flexible film scintillators using graphene, perovskite, and 2D materials. Furthermore, numerous fabrication methods that improve the performance through the doping of nanomaterials on the surface have been introduced. Herein, we provide an in-depth review of the findings pertaining to nanomaterial-based scintillators to gain a better understanding of radiological detection technological applications.

25 August 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
SMsujung min
sujung min
YKYoungsu Kim
Youngsu Kim
KKKwang-Hoon Ko
Kwang-Hoon Ko
BSBumkyung Seo
Bumkyung Seo
JCJae Hak Cheong
Jae Hak Cheong
SHSang Bum Hong
Sang Bum Hong
Plastic scintillators are widely used in various radiation measurement applications, and the use of plastic scintillators for nuclear applications including decommissioning, such as gamma-ray detection and measurement, is an important concern. With regard to efficient and effective gamma-ray detection, the optimization for thickness of plastic scintillator is strongly needed. Here, we elucidate optimization of the thickness of high-performance plastic scintillator using high atomic number material. Moreover, the EJ-200 of commercial plastic scintillators with the same thickness was compared. Two computational simulation codes (MCNP, GEANT4) were used for thickness optimization and were compared with experimental results to verify data obtained by computational simulation. From the obtained results, it was confirmed that the difference in total counts was less than 10% in the thickness of the scintillator of 50 mm or more, which means optimized thickness for high efficiency gamma-ray detection such as radioactive 137Cs and 60CO. Finally, simulated results, along with experimental data, were discussed in this study. The results of this study can be used as basic data for optimizing the thickness of plastic scintillators using high atomic number elements for radiation detection and monitoring.

8 March 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
HKHara Kang
Hara Kang
SMsujung min
sujung min
BSBumkyung Seo
Bumkyung Seo
Changhyun RohChanghyun Roh
Changhyun Roh
SHSang Bum Hong
Sang Bum Hong
JCJae Hak Cheong
Jae Hak Cheong
Functional plastic scintillators have attracted much attention for their usefulness in on-site monitoring and detection in environments. In this study, we elucidated a highly reliable and functional plastic scintillator for detection of radioactive strontium, which means a potent perovskite-loaded polymeric scintillation material based on epoxy and 2,5-diphenyloxazole (PPO). Moreover, Monte Carlo N-Particle (MCNP) simulation was performed to optimize the thickness of a plastic scintillator for efficient strontium detection. A thickness of 2 mm was found to be the optimum thickness for strontium beta-ray detection. A newly developed plastic scintillator with 430 nm emission from perovskite loading could trigger scintillation enhancement employing potential indication of perovskite energy transfer into a photomultiplier (PMT) detector. Furthermore, the response to beta-ray emitter of 90Sr was compared to commercial scintillator of BC-400 by exhibiting detection efficiency in the energy spectrum with a fabricated perovskite-loaded plastic scintillator. We believe that this suggested functional plastic scintillator could be employed as a radiation detector for strontium detection in a wide range of applications including decommissioning sites in nuclear facilities, nuclear security and monitoring, nonproliferation, and safeguards.