Annarita Imperante

Dr. Annarita Imperante

Università degli Studi di Bari, D.E.T.O.
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
AIAnnarita Imperante
Annarita Imperante
LFLaura Fracassi
Laura Fracassi
ACAlberto Maria Crovace
Alberto Maria Crovace
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
As an alternative to the surgical robot, some medical companies have engineered new steerable devices that mimic the robot’s capacities. This study aimed to assess how steerable instruments ameliorate the efficacy of suturing in comparison with the traditional instrument, and a combination instruments, performed by experienced and novice surgeons. The study was performed by three experienced surgeons and three novice surgeons. The instruments employed were divided into three surgical sets: two steerable dissectors; one steerable dissector and one straight needle; two straight needle holders. The study supervisor recorded the total time for the procedure, the number of bites completed, the time for each bite, and the quality of the procedure. In our study, we found consistent data demonstrating that experienced laparoscopists completed the prescribed suture pattern with more bites in less time than novices. The use of two steerable instruments was more time consuming than standard straight instruments, but a combination of instruments was significantly less time consuming, as was the use of two straight needle holders. This result was even observed in novice surgeons. Combining a steerable instrument with a traditional straight needle holder provided more advantages in this study.

6 April 2020 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
AIAnnarita Imperante
Annarita Imperante
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
RSRocco De Siena
Rocco De Siena
PLPasquale De Luca
Pasquale De Luca
ACANTONIO CROVACE
ANTONIO CROVACE
The study evaluated the intra- and inter-observer measurement variability of an osteophytosis metacarpophalangeal joint scoring system. Ten (n = 10) dorso/palmar, latero/medial, and oblique views of equine metacarpophalangeal joints affected by osteoarthritis were examined. Nine assessment points were graded (scale: 0–3) twice by five veterinary students (inexperienced group, I) and four equine veterinary surgeons (expert group, E). The grades for each of the nine factors were summed to obtain the osteophytosis score. The variability between the two measurements was −2.04 ± 3.5, 95% CI −3.04 to −1.03 for the I group. For the E group, they were 0 ± 1.43, 95% CI −0.45 to 0.45. In the evaluation of the same radiographs, the I group had a coefficient of variability (CV) of 37.29%. The correlation was r = 0.90%. The CV between groups was 28.85%. The mean difference between the two observations was -0.03 ± 0.29 in the E group and 0.22 ± 0.77 in the I group. The I group showed a greater CV when the score was low (r = −0.78) compared to the E group, where the CV was independent of severity of osteophytosis (r = −0.47). The osteophytosis scoring system is an easily applicable and feasible system to be used by observers with different levels of experience, but inexpert observers may need additional training or may need to be helped by reference images. These data are validated by the low inter- and intra-observer measurement variability results in the E group. Therefore, the scoring system proposed seems to be a repeatable instrument applicable to the radiographic score of the severity of metacarpophalangeal joint osteoarthritis.

1 September 2020 in Journal of Equine Veterinary Science
Verified
Journal Article
Closed access
LLLuca Lacitignola
Luca Lacitignola
AIAnnarita Imperante
Annarita Imperante
RSRocco De Siena
Rocco De Siena
CAClaudia Acquafredda
Claudia Acquafredda
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
FSFrancesco Staffieri
Francesco Staffieri

10 March 2022 in Animals
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
PLPietro Laricchiuta
Pietro Laricchiuta
AIAnnarita Imperante
Annarita Imperante
CAClaudia Acquafredda
Claudia Acquafredda
Marzia StabileMarzia Stabile
Marzia Stabile
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
The aim of this study was to assess the feasibility and intraoperative complications of performing ovariectomies in African lionesses (Panthera leo) using a wound retractor laparoscopic platform. Six lionesses (n = 6) were included. The surgical procedures were carried out through three portals, with a retractor platform positioned at the umbilical port and cannulas placed 3–4 cm from the cranial and caudal regions to the device at the level of the midline. An ovariectomy was performed with a vessel-sealing device. We evaluated the surgery time and the intraoperative and early postoperative complications. The mean weight was 172.83 kg. The total surgery time was 49.33 min. The installation step took a mean of 10.33 min to complete. The mean ovariectomy time was 20 min. Controlled bleeding was observed at the tip of the uterine horn in two cases due to excessive tissue thickness. The retrieval of dissected ovarian tissue and annexes was easily performed. No other complications were observed. The use of the laparoscopic platform during three-portal surgeries for laparoscopic ovariectomy in adult overweight lionesses is feasible and without intraoperative problems. The retractor meant that there were no entry-related issues due to the 25 mm mini-laparotomy. It also made it simpler to extract thick ovaries and promptly re-establish the pneumoperitoneum.

18 December 2023 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
STSimone Della Tommasa
Simone Della Tommasa
WBWalter Brehm
Walter Brehm
Giacomo FarìGiacomo Farì
Giacomo Farì
Andrea BernettiAndrea Bernetti
Andrea Bernetti
AIAnnarita Imperante
Annarita Imperante
The utilization of Autologous Conditioned Serum (ACS) for treating osteoarthritis (OA) in horses has seen a notable increase in recent years. In vitro studies have consistently identified ACS as a promising therapy for OA joints, contributing to its growing popularity in OA treatment. Despite this, there is a noticeable absence of systematic reviews focused solely on the clinical data of OA patients treated with ACS, excluding the in vitro perspective. This study aims to address this gap by systematically reviewing the latest literature, concentrating solely on clinical data in in vivo studies to evaluate the efficacy of ACS in OA lesions. All clinical studies involving ACS treatments for horses with OA were included in the assessment. Surprisingly, only six trials met the inclusion criteria for this systematic review. The results indicate that the majority of the considered articles support the use of ACS as a treatment for horses, albeit with a control group provided in only one study. However, the absence of a control group and the exclusion of histological evaluation diminish the validity of the majority of clinical research. While several studies suggest a beneficial effect of ACS on OA horses without significant adverse effects, this systematic review affirms that there is no definitive evidence for its effectiveness. Therefore, further investigation of the efficacy of ACS products as a treatment for OA is warranted, emphasizing the need for more controlled trials. Poorly designed and biased studies, lacking blinding or control and adopting inadequate outcome measures, may favor positive results and, thus, necessitate a more rigorous approach to validate the efficacy of ACS in OA treatment.

22 February 2021 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
AIAnnarita Imperante
Annarita Imperante
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
NZNicola Zizzo
Nicola Zizzo
ACAlberto Crovace
Alberto Crovace
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.