Rodrigo Trisciuzzi

Dr. Rodrigo Trisciuzzi


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2019 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
LFLaura Fracassi
Laura Fracassi
HMHernando Afonso Martin
Hernando Afonso Martin
DMDonato Monopoli
Donato Monopoli
DADaniel Amat
Daniel Amat
ACAlberto Crovace
Alberto Crovace
Tibial Tuberosity Advancement (TTA) is a surgical technique based on a linear osteotomy that determines a cranial advancement of the tibial tuberosity in patients suffering from cranial cruciate ligament rupture (CCL). The aim is to neutralize the cranial tibial thrust (CTT) and to reach a 90° angle between the patellar tendon and the tibial plateau with a physiological knee extension of 135°. In our study, a Ti6AI4V ELI (Titanium Aluminium Vanadium) titanium scaffold for the Porous TTA, with excellent properties of osteointegration and osteoconduction when subjected to cyclic loading has been adopted. Based on the previous scientific work on an ovine model, the use of this type of porous scaffolds has subverted the previous models. Scaffold production technology is based on direct mechanical manufacturing called Electron Beam Melting (EBM). For this study, 41 dogs, different breeds, medium-large size, weighing between 10 and 80 kg, aged between 1 and 13 years, were enrolled. The inclusion criteria were based on clinical evaluations (different gaits), drawer test and tibial compression, LOAD score (Liverpool Osteoarthritis in Dogs questionnaire), radiographic diagnosis in sedation with a 135° positioning of the joint and baropodometric investigations (Stance Analyzer). The results show that Porous TTA is an excellent method for functional recovery of the knee joint following the partial and total rupture of the CCL.

15 September 2020 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
AIAnnarita Imperante
Annarita Imperante
LFLaura Fracassi
Laura Fracassi
ACAlberto Maria Crovace
Alberto Maria Crovace
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
As an alternative to the surgical robot, some medical companies have engineered new steerable devices that mimic the robot’s capacities. This study aimed to assess how steerable instruments ameliorate the efficacy of suturing in comparison with the traditional instrument, and a combination instruments, performed by experienced and novice surgeons. The study was performed by three experienced surgeons and three novice surgeons. The instruments employed were divided into three surgical sets: two steerable dissectors; one steerable dissector and one straight needle; two straight needle holders. The study supervisor recorded the total time for the procedure, the number of bites completed, the time for each bite, and the quality of the procedure. In our study, we found consistent data demonstrating that experienced laparoscopists completed the prescribed suture pattern with more bites in less time than novices. The use of two steerable instruments was more time consuming than standard straight instruments, but a combination of instruments was significantly less time consuming, as was the use of two straight needle holders. This result was even observed in novice surgeons. Combining a steerable instrument with a traditional straight needle holder provided more advantages in this study.

22 February 2021 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
LLLuca Lacitignola
Luca Lacitignola
AIAnnarita Imperante
Annarita Imperante
RTRodrigo Trisciuzzi
Rodrigo Trisciuzzi
NZNicola Zizzo
Nicola Zizzo
ACAlberto Crovace
Alberto Crovace
Francesco  StaffieriFrancesco Staffieri
Francesco Staffieri
This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.