Ravikumar  Ramakrishnaiah

Dr. Ravikumar Ramakrishnaiah

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah
AKAbdul Aziz Abdullah Al Kheraif
Abdul Aziz Abdullah Al Kheraif
DDDarshan Devang Divakar
Darshan Devang Divakar
JMJukka Matinlinna
Jukka Matinlinna
PVPekka Vallittu
Pekka Vallittu
The current laboratory study is evaluating the effect of hydrofluoric acid etching duration on the surface characteristics of five silica-based glass ceramics. Changes in the pore pattern, crystal structure, roughness, and wettability were compared and evaluated. Seventy-five rectangularly shaped specimens were cut from each material (IPS e-max™, Dentsply Celtra™, Vita Suprinity™, Vita mark II™, and Vita Suprinity FC™); the sectioned samples were finished, polished, and ultrasonically cleaned. Specimens were randomly assigned into study groups: control (no etching) and four experimental groups (20, 40, 80 and 160 s of etching). The etched surfaces’ microstructure including crystal structure, pore pattern, pore depth, and pore width was studied under a scanning electron microscope, and the surface roughness and wettability were analyzed using a non-contact surface profilometer and a contact angle measuring device, respectively. The results were statistically analyzed using one-way analysis of variance (ANOVA) and the post hoc Tukey’s test. The results showed a significant change in the pore number, pore pattern, crystal structure, surface roughness, and wettability with increased etching duration. Etching for a short time resulted in small pores, and etching for longer times resulted in wider, irregular grooves. A significant increase in the surface roughness and wettability was observed with an increase in the etching duration. The findings also suggested a strong association between the surface roughness and wettability.

1 May 2017 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah
AKAbdulaziz Abdullah Al Kheraif
Abdulaziz Abdullah Al Kheraif
AMAshfaq Mohammad
Ashfaq Mohammad
DDDarshan Devang Divakar
Darshan Devang Divakar
SKSunil Babu Kotha
Sunil Babu Kotha
Ihtesham RehmanIhtesham Rehman
Ihtesham Rehman
The current study was aimed to fabricate customized root form dental implant using additive manufacturing technique for the replacement of missing teeth. The root form dental implant was designed using Geomagic™ and Magics™, the designed implant was directly manufactured by layering technique using ARCAM A2™ electron beam melting system by employing medical grade Ti-6Al-4V alloy powder. Furthermore, the fabricated implant was characterized in terms of certain clinically important parameters such as surface microstructure, surface topography, chemical purity and internal porosity. Results confirmed that, fabrication of customized dental implants using additive rapid manufacturing technology offers an attractive method to produce extremely pure form of customized titanium dental implants, the rough and porous surface texture obtained is expected to provide better initial implant stabilization and superior osseointegration.

1 August 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MAMoshabab Asiry
Moshabab Asiry
IAIbrahim AlShahrani
Ibrahim AlShahrani
SASamer M. Alaqeel
Samer M. Alaqeel
BDBangalore Durgesh
Bangalore Durgesh
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah

26 October 2016 in Journal of Investigative and Clinical Dentistry
Verified
Journal Article
Closed access
PDF file
SKSunil Babu Kotha
Sunil Babu Kotha
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah
DDDarshan Devang Divakar
Darshan Devang Divakar
SCSree Lalita Celur
Sree Lalita Celur
SQSyed Saad Bin Qasim
Syed Saad Bin Qasim
JMJukka P. Matinlinna
Jukka P. Matinlinna

1 January 2015 in Dental Materials Journal
Verified
Journal Article
Open access
Mohammed AlshehriMohammed Alshehri
Mohammed Alshehri
JBJagan Baskaradoss
Jagan Baskaradoss
AGAmrita Geevarghese
Amrita Geevarghese
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah
DTDimitris N. Tatakis
Dimitris N. Tatakis
The present in vitro study sought to determine the effects of myrrh-containing solutions on common suture materials used in periodontal surgery. Three commonly used suture materials (silk, polyglactin 910, polytetrafluoroethylene) were immersed in four thermostatically controlled experimental media to simulate daily oral rinsing activity, namely -artificial saliva, normal saline solution with 0.2% Commiphora myrrh, full-concentration (100%) Commiphora myrrh oil, and a myrrh-containing commercial mouthwash. Tensile strength was measured at the end of each day using an Instron tensile testing machine. Silk sutures were susceptible to tensile strength loss when exposed to 0.2% myrrh solution once daily for 5 days. Myrrh-containing commercial mouthwash had no effect on tensile strength, but all three suture materials lost tensile strength when exposed to 100% myrrh oil. For patients that routinely use myrrh mouthwashes postoperatively, findings of this study suggested that silk sutures might not be the optimal material choice.

9 March 2018 in Silicon
Verified
Journal Article
Closed access
PDF file
RRRavikumar Ramakrishnaiah
Ravikumar Ramakrishnaiah
AAAbdulaziz Abdullah Alkheraif
Abdulaziz Abdullah Alkheraif
DDDarshan Devang Divakar
Darshan Devang Divakar
KAKhuloud Fahad Alghamdi
Khuloud Fahad Alghamdi
JMJukka Pekka Matinlinna
Jukka Pekka Matinlinna
PVPekka Kalevi Vallittu
Pekka Kalevi Vallittu