Between 60% and 70% of the total energy load of a house or office occurs through the exteriors of the building, and in the case of offices, heat loss from windows and doors can approach 40%. A need for glass that can artificially control the transmittance of visible light has therefore emerged. Smart windows with suspended particle device (SPD) film can reduce energy consumption by responding to environmental conditions. To measure the effect of SPD windows on the energy requirements for cooling and heating in Korea, we installed a testbed with SPD windows. With TRNSYS18, the comparison between measurements and simulation has been made in order to validate the simulation model with respect to the modeling of an SPD window. Furthermore, the energy requirements of conventional and SPD-applied windows were compared and analyzed for a standard building that represented an actual office building. When weather for the city of Anseong and a two-speed heat pump were used to verify the simulation, the simulated electricity consumption error compared with the testbed was −1.0% for cooling and −0.9% for heating. The annual electricity consumption error was −0.9%. When TMY2 Seoul weather data were applied to the reference building, the decrease in electricity consumption for cooling in the SPD model compared with the non-SPD model was 29.1% and the increase for heating was 15.8%. Annual electricity consumption decreased by 4.1%.
In the present study, a novel combined power cycle for solar power tower (SPT) system consisting of helium Brayton cycle (HBC) and transcritical CO2 (TCO2) for waste heat recovery is being studied for carbon‐free generation. The performance of the proposed SPT based combined cycle (SPT‐HBC‐TCO2 cycle) is compared with SPT based basic cycle (SPT‐HBC) based on exergoeconomic and thermodynamic analyses. It is concluded that the SPT‐based combined cycle (SPT‐HBC‐TCO2 cycle) produces a thermal efficiency of 32.39% and exergy efficiency of 34.68% with an electricity cost of 1.613 UScent kWh−1. The exergy and thermal efficiency of the SPT‐based combined cycle are enhanced by 13.18% and 13.21% respectively, while electricity cost is reduced by around 2% as compared to the SPT‐based basic cycle (SPT‐HBC) configuration at base conditions. A notable finding is that, despite the additional expenditures related to the bottoming cycle, the cost of electricity is lesser for the proposed combined cycle. Additionally, a comparison with the related prior published research exhibits that the performance of the current novel system is superior to that of the systems based on steam rankine cycle and supercritical CO2 cycles.
In South Korea, we are aiming for net zero energy use apartment home structures. Since the apartment structure in South Korea is generally a high-rise of 10 or more floors, the types of renewable energy applicable are limited to photovoltaic (PV) panels, solar collectors installed on the wall, or a photovoltaic thermal (PVT) hybrid panel combining both. In this study, the effect of PV, ST (Solar Thermal), and PVT systems on greenhouse gas reduction was analyzed using TRNSYS18. All three systems showed maximum CO2 reductions at 35° facing south. PV, ST, and PVT showed CO2 reductions of 67.4, 114.6, and 144.7 kg_CO2/m2·year, respectively. Compared to those values, when installed on a wall (slope of 90°), CO2 reduction is about 35–40% less and about 20% less at a slope of 75°. ST and PVT installed on the vertical wall have a greater greenhouse gas reduction effect than the PV installed at the optimal slope of 35°. Since the CO2 reduction difference among SW, SE, and azimuthal S is within 10%, ST and PVT are recommended for installation on high-rise apartment structure walls or balconies with the azimuthal angle of ± 45° with respect to south.
13 March 2020 in Journal of Energy Resources Technology