The present study deals with performance analysis of solar power tower powered combined pre-compression supercritical CO2 cycle and organic Rankine cycle (ORC) for recovering waste heat. Results showed that net power output and thermal efficiency of pre-compression cycle was improved by 4.51 and 4.52%, respectively, using ORC. Highest thermal, exergy efficiency, and power output of the combined cycle increased with solar irradiation having highest values 51.83, 74.06%, and 278.5 kW at 1000 W/m2 of solar irradiation using R227ea. Waste heat recovery ratio increased with heat exchanger effectiveness. Its highest value was found as 0.5673 at 0.95 of effectiveness based on R227ea.
9 July 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Thermodynamic analysis of the combined partial heating supercritical CO2 (PSCO2) cycle and ORC is presented in this study. In engineering equation solver software, a computer program was created for parametric analysis of the model. Basic PSCO2 cycle was then compared with existing previous studies that were conducted without partial heating. It was concluded that the PSCO2 system was 1 to 3% thermally more efficient than the non-partial heating cycle. Furthermore, it was found that ORC’s use in existing PSCO2 cycle improved thermal efficiency by 4.47% of the basic PSCO2 cycle. The effects of the parabolic trough collectors (PTSCs) on the combined cycle performance were further examined. Without taking into account the performance of the PTSCs, the highest exergy and thermal efficiency of the combined cycle using R1233zd(E) was achieved by 83.26 and 48.61%, respectively at 950 W/m2 of solar irradiation while taking into account the performance of PTSCs, the combined cycle achieved exergy efficiency by 42.31% because PTSCs alone accounted for 62.93% of the total exergy destruction. One of the other conclusions obtained from the results was that the highest solar incidence angle was responsible for poor system performance.
In the present study, a novel combined power cycle for solar power tower (SPT) system consisting of helium Brayton cycle (HBC) and transcritical CO2 (TCO2) for waste heat recovery is being studied for carbon‐free generation. The performance of the proposed SPT based combined cycle (SPT‐HBC‐TCO2 cycle) is compared with SPT based basic cycle (SPT‐HBC) based on exergoeconomic and thermodynamic analyses. It is concluded that the SPT‐based combined cycle (SPT‐HBC‐TCO2 cycle) produces a thermal efficiency of 32.39% and exergy efficiency of 34.68% with an electricity cost of 1.613 UScent kWh−1. The exergy and thermal efficiency of the SPT‐based combined cycle are enhanced by 13.18% and 13.21% respectively, while electricity cost is reduced by around 2% as compared to the SPT‐based basic cycle (SPT‐HBC) configuration at base conditions. A notable finding is that, despite the additional expenditures related to the bottoming cycle, the cost of electricity is lesser for the proposed combined cycle. Additionally, a comparison with the related prior published research exhibits that the performance of the current novel system is superior to that of the systems based on steam rankine cycle and supercritical CO2 cycles.
28 January 2024 in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering