Magdalena Jażdżewska

Dr. Magdalena Jażdżewska

Gdańsk University of Technology, Faculty of Mechanical Engineering
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
Michał BartmańskiMichał Bartmański
Michał Bartmański
GSGabriel Strugała
Gabriel Strugała
Aleksandra Mielewczyk-GryńAleksandra Mielewczyk-Gryń
Aleksandra Mielewczyk-Gryń
MJMagdalena Jażdżewska
Magdalena Jażdżewska
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Currently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition was carried out for different parameters like the content of EE100, time of deposition, and applied voltage. The microstructure, surface roughness, chemical and phase composition, wettability, mechanical and electrochemical properties, and degradation rate at different pH were examined in comparison to chitosan coating without the addition of Eudragit E 100. The applied deposition parameters significantly influenced the morphology of the coatings. The chit/EE100 coating with the highest homogeneity was obtained for Eudragit content of 0.25 g, at 10 V, and for 1 min. Young’s modulus of this sample (24.77 ± 5.50 GPa) was most comparable to that of human cortical bone. The introduction of Eudragit E 100 into chitosan coatings significantly reduced their degradation rate in artificial saliva at neutral pH while maintaining high sensitivity to pH changes. The chit/EE100 coatings showed a slightly lower corrosion resistance compared to the chitosan coating, however, significantly exceeding the substrate corrosion resistance. All prepared coatings were characterized by hydrophilicity.

1 November 2019 in Ceramics International
Verified
Journal Article
Closed access
Michał BartmańskiMichał Bartmański
Michał Bartmański
AZAndrzej Zielinski
Andrzej Zielinski
MJMagdalena Jażdżewska
Magdalena Jażdżewska
JGJoanna Głodowska
Joanna Głodowska
PKPamela Kalka
Pamela Kalka

27 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
MDMagda Dziaduszewska
Magda Dziaduszewska
Beata Majkowska-MarzecBeata Majkowska-Marzec
Beata Majkowska-Marzec
MJMagdalena Jażdżewska
Magdalena Jażdżewska
Michał BartmańskiMichał Bartmański
Michał Bartmański
PSPamela Samsel
Pamela Samsel
Titanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment, deposition of chitosan, biodegradable Eudragit 100 and poly(4-vinylpyridine (P4VP), carbon nanotubes, nanoparticles of TiO2, and chitosan with Pt (nano Pt) and polymeric dispersant. The open circuit potential, corrosion current density, and potential values were determined by potentiodynamic technique, and microstructures of the surface layers and coatings were characterized by scanning electron microscopy. The results show that despite the applied modifications, the corrosion current density still appears in the region of very low values of some nA/cm2. However, almost all surface modifications, designed principally for the improvement of biological properties, negatively influence corrosion resistance. The reasons for observed effects can vary, such as imperfections and permeability of some coatings or accelerated degradation of biodegradable deposits in simulated body fluids during electrochemical testing. Despite that, all coatings can be accepted for biological applications, and such corrosion testing results are presumed not to be of major importance for their applications in medicine.

22 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
MJMagdalena Jażdżewska
Magdalena Jażdżewska
DKDominika Beata Kwidzińska
Dominika Beata Kwidzińska
WSWiktor Seyda
Wiktor Seyda
DFDariusz Fydrych
Dariusz Fydrych
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Nowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze the properties of the obtained surface layers, the following tests were performed: scanning electron microscopy, chemical and phase composition analysis, wetting angle tests and roughness tests. The assessment of the impact of the laser modification on the internal stresses of the investigated materials was carried out by comparing the values of the stresses of the laser-modified samples to those of the reference samples. The obtained results showed increased values of tensile stresses after laser modification: the highest value was found for the Ti-6Al-4V alloy at 6.7434 GPa and the lowest for pure grade IV titanium at 3.742 GPa. After laser and heat treatment, a reduction in the stress was observed, together with a significant increase in the hardness of the tested materials, with the highest value for Ti-6Al-4V alloy at 27.723 GPa. This can provide better abrasion resistance and lower long-term toxicity, both of which are desirable when using Ti-6Al-4V and Ti-13Nb-13Zr alloys for implant materials.

1 December 2017 in Advances in Materials Science
Verified
Journal Article
Open access
PDF file
MJMagdalena Jażdżewska
Magdalena Jażdżewska
Beata Majkowska-MarzecBeata Majkowska-Marzec
Beata Majkowska-Marzec
The Ti13Nb13Zr alloy was subjected to laser modification with the Nd:YAG laser provided that such treatment would increase the surface roughness followed improved adhesion of hydroxyapatite (HAp) coatings The hydroxyapatite was deposited by electrophoretic method in suspension of 0.5 g HA powder and 100 ml ethyl alcohol. The deposition was carried out for 10 min at 10 V voltage followed by drying at room temperature for 24 h and heating at 800°C for 1 h in vacuum. The thickness of the HAp coatings was found as of about 4.06 μm to 9.05 μm. The examinations of surfaces were carried out at each stage of the experiment with the ultra-high resolution scanning electron microscope. The measurements of surface roughness after laser treatment and after HAp deposition were performed with the Hommel Etamic Waveline profilograph.

1 March 2020 in Advances in Materials Science
Verified
Journal Article
Open access
PDF file
MJMagdalena Jażdżewska
Magdalena Jażdżewska
The titanium alloys are materials susceptible to tribological wear and the laser treatment can be applied in surface treatment processes to obtain for example higher hardness level. From the other side, it is important to take into consideration, that hardness increase that can be connected with cracks. The aim of this research was to investigate the effects of different lasers and the process parameters on the form and level of residual stresses in the Ti6Al4V alloy, which determine the initiation and propagation of cracking. Two lasers were used, the CO 2 and Nd:YAG lasers. The specimens were remelted in liquid nitrogen, water or calm air at different pre-heating temperature. The different laser power and scan rates were applied. The increase in energy density increased the number of cracks, the change of an environment and pre-heating affected alo the surface cracking. The cracks observed after remelting with Nd:YAG laser were longer than those observed after treatment with CO 2 laser. The compressive stresses after the CO 2 laser treatment, and tensile stresses after treatment with the Nd:YAG laser, were found. The appearance of cracks was attributed to an excessive energy density. The different distribution of heat energy inside and around the laser tracks was discussed as the origin of presence either tensile or compressive stresses in the alloy treated with different lasers.