Łukasz Pawłowski

Mr. Łukasz Pawłowski

Gdańsk University of Technology, Gdańsk, Pomorskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Ceramics International
Verified
Journal Article
Closed access
Michał BartmańskiMichał Bartmański
Michał Bartmański
BCBartłomiej Michał Cieślik
Bartłomiej Michał Cieślik
JGJoanna Glodowska
Joanna Glodowska
PKPamela Kalka
Pamela Kalka
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
AZAndrzej Zielinski
Andrzej Zielinski

28 June 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
Michał BartmańskiMichał Bartmański
Michał Bartmański
GSGabriel Strugała
Gabriel Strugała
Aleksandra Mielewczyk-GryńAleksandra Mielewczyk-Gryń
Aleksandra Mielewczyk-Gryń
MJMagdalena Jażdżewska
Magdalena Jażdżewska
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Currently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition was carried out for different parameters like the content of EE100, time of deposition, and applied voltage. The microstructure, surface roughness, chemical and phase composition, wettability, mechanical and electrochemical properties, and degradation rate at different pH were examined in comparison to chitosan coating without the addition of Eudragit E 100. The applied deposition parameters significantly influenced the morphology of the coatings. The chit/EE100 coating with the highest homogeneity was obtained for Eudragit content of 0.25 g, at 10 V, and for 1 min. Young’s modulus of this sample (24.77 ± 5.50 GPa) was most comparable to that of human cortical bone. The introduction of Eudragit E 100 into chitosan coatings significantly reduced their degradation rate in artificial saliva at neutral pH while maintaining high sensitivity to pH changes. The chit/EE100 coatings showed a slightly lower corrosion resistance compared to the chitosan coating, however, significantly exceeding the substrate corrosion resistance. All prepared coatings were characterized by hydrophilicity.

6 March 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Michał BartmańskiMichał Bartmański
Michał Bartmański
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Aleksandra Mielewczyk-GryńAleksandra Mielewczyk-Gryń
Aleksandra Mielewczyk-Gryń
GSGabriel Strugała
Gabriel Strugała
BCBartłomiej Michał Cieślik
Bartłomiej Michał Cieślik
The surface treatment of titanium implants has been applied mainly to increase surface bioactivity and, more recently, to introduce antibacterial properties. To this end, composite coatings have been investigated, particularly those based on hydroxyapatite. The present research was aimed at the development of another coating type, chitosan–nanosilver, deposited on a Ti13Zr13Nb alloy. The research comprised characterization of the coating’s microstructure and morphology, time-dependent nanosilver dissolution in simulated body fluid, and investigation of the nanomechanical properties of surface coatings composed of chitosan and nanosilver, with or without a surface-active substance, deposited at different voltages for 1 min on a nanotubular TiO2 layer. The microstructure, morphology, topography, and phase composition were examined, and the silver dissolution rate in simulated body fluid, nanoscale mechanical properties, and water contact angle were measured. The voltage value significantly influenced surface roughness. All specimens possessed high biocompatibility. The highest and best adhesion of the coatings was observed in the absence of a surface-active substance. Silver dissolution caused the appearance of silver ions in solution at levels effective against bacteria and below the upper safe limit value.

12 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
Michał BartmańskiMichał Bartmański
Michał Bartmański
Aleksandra Mielewczyk-GryńAleksandra Mielewczyk-Gryń
Aleksandra Mielewczyk-Gryń
BCBartłomiej Michał Cieślik
Bartłomiej Michał Cieślik
GGGrzegorz Gajowiec
Grzegorz Gajowiec
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Due to the possibility of bacterial infections occurring around peri-implant tissues, it is necessary to provide implant coatings that release antibacterial substances. The scientific goal of this paper was to produce by electrophoretic deposition (EPD) a smart, chitosan/Eudragit E 100/silver nanoparticles (chit/EE100/AgNPs) composite coating on the surface of titanium grade 2 using different deposition parameters, such as the content of AgNPs, applied voltage, and time of deposition. The morphology, surface roughness, thickness, chemical and phase composition, wettability, mechanical properties, electrochemical properties, and silver release rate at different pH were investigated. Using lower values of deposition parameters, coatings with more homogeneous morphology were obtained. The prepared coatings were sensitive to the reduced pH environment.

27 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
MDMagda Dziaduszewska
Magda Dziaduszewska
Beata Majkowska-MarzecBeata Majkowska-Marzec
Beata Majkowska-Marzec
MJMagdalena Jażdżewska
Magdalena Jażdżewska
Michał BartmańskiMichał Bartmański
Michał Bartmański
PSPamela Samsel
Pamela Samsel
Titanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment, deposition of chitosan, biodegradable Eudragit 100 and poly(4-vinylpyridine (P4VP), carbon nanotubes, nanoparticles of TiO2, and chitosan with Pt (nano Pt) and polymeric dispersant. The open circuit potential, corrosion current density, and potential values were determined by potentiodynamic technique, and microstructures of the surface layers and coatings were characterized by scanning electron microscopy. The results show that despite the applied modifications, the corrosion current density still appears in the region of very low values of some nA/cm2. However, almost all surface modifications, designed principally for the improvement of biological properties, negatively influence corrosion resistance. The reasons for observed effects can vary, such as imperfections and permeability of some coatings or accelerated degradation of biodegradable deposits in simulated body fluids during electrochemical testing. Despite that, all coatings can be accepted for biological applications, and such corrosion testing results are presumed not to be of major importance for their applications in medicine.

13 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
Michał BartmańskiMichał Bartmański
Michał Bartmański
Łukasz PawłowskiŁukasz Pawłowski
Łukasz Pawłowski
GSGabriel Strugała
Gabriel Strugała
Aleksandra Mielewczyk-GryńAleksandra Mielewczyk-Gryń
Aleksandra Mielewczyk-Gryń
Andrzej ZielinskiAndrzej Zielinski
Andrzej Zielinski
Nowadays, hydroxyapatite coatings are the most common surface modification of long-term implants. These coatings are characterized by high thickness and poor adhesion to the metallic substrate. The present research is aimed at characterizing the properties of nanohydroxyapatite (nanoHAp) with the addition of copper nanoparticle (nanoCu) coatings deposited on the Ti13Zr13Nb alloy by an electrophoresis process. The deposition of coatings was carried out for various amounts of nanoCu powder and various average particle sizes. Microstructure, topography, phase, and chemical composition were examined with scanning electron microscopy, atomic force microscopy, and X-ray diffraction. Corrosion properties were determined by potentiodynamic polarization technique in simulated body fluid. Nanomechanical properties were determined based on nanoindentation and scratch tests. The wettability of coatings was defined by the contact angle. It was proven that nanoHAp coatings containing nanocopper, compared to nanoHAp coatings without nanometals, demonstrated smaller number of cracks, lower thickness, and higher nanomechanical properties. The influence of the content and the average size of nanoCu on the quality of the coatings was observed. All coatings exhibited hydrophilic properties. The deposition of nanohydroxyapatite coatings doped with nanocopper may be a promising way to improve the antibacterial properties and mechanical stability of coatings.