Roland Hoffmann

Dr. Roland Hoffmann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Respiratory Research
Verified
Journal Article
Open access
PDF file
RHRoland Hoffmann
Roland Hoffmann
SZSina Zarrintan
Sina Zarrintan
SBSimone M Brandenburg
Simone M Brandenburg
AKArjan Kol
Arjan Kol
HBHarold G de Bruin
Harold G de Bruin
Irene HeijinkIrene Heijink
Irene Heijink
Cigarette smoking is the major risk factor for COPD, leading to chronic airway inflammation. We hypothesized that cigarette smoke induces structural and functional changes of airway epithelial mitochondria, with important implications for lung inflammation and COPD pathogenesis.

1 April 2015 in Mutation Research - Reviews in Mutation Research
Verified
Journal Article
Open access
MGMarike Van Gisbergen
Marike Van Gisbergen
AVA.M. Voets
A.M. Voets
MSM.H.W. Starmans
M.H.W. Starmans
ICI.F.M. de Coo
I.F.M. de Coo
RYR. Yadak
R. Yadak
PLP. Lambin
P. Lambin
Several mutations in nuclear genes encoding for mitochondrial components have been associated with an increased cancer risk or are even causative, e.g. succinate dehydrogenase (SDHB, SDHC and SDHD genes) and iso-citrate dehydrogenase (IDH1 and IDH2 genes). Recently, studies have suggested an eminent role for mitochondrial DNA (mtDNA) mutations in the development of a wide variety of cancers. Various studies associated mtDNA abnormalities, including mutations, deletions, inversions and copy number alterations, with mitochondrial dysfunction. This might, explain the hampered cellular bioenergetics in many cancer cell types. Germline (e.g. m.10398A>G; m.6253T>C) and somatic mtDNA mutations as well as differences in mtDNA copy number seem to be associated with cancer risk. It seems that mtDNA can contribute as driver or as complementary gene mutation according to the multiple-hit model. This can enhance the mutagenic/clonogenic potential of the cell as observed for m.8993T>G or influences the metastatic potential in later stages of cancer progression. Alternatively, other mtDNA variations will be innocent passenger mutations in a tumor and therefore do not contribute to the tumorigenic or metastatic potential. In this review, we discuss how reported mtDNA variations interfere with cancer treatment and what implications this has on current successful pharmaceutical interventions. Mutations in MT-ND4 and mtDNA depletion have been reported to be involved in cisplatin resistance. Pharmaceutical impairment of OXPHOS by metformin can increase the efficiency of radiotherapy. To study mitochondrial dysfunction in cancer, different cellular models (like ρ(0) cells or cybrids), in vivo murine models (xenografts and specific mtDNA mouse models in combination with a spontaneous cancer mouse model) and small animal models (e.g. Danio rerio) could be potentially interesting to use. For future research, we foresee that unraveling mtDNA variations can contribute to personalized therapy for specific cancer types and improve the outcome of the disease.

19 April 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ALAnnemieke Oude Lansink-Hartgring
Annemieke Oude Lansink-Hartgring
RHRoland Hoffmann
Roland Hoffmann
WBW.M. Van Den Bergh
W.M. Van Den Bergh
AVAdrianus de Vries
Adrianus de Vries
Extracorporeal membrane oxygenation (ECMO) is associated with frequent hemorrhagic and thromboembolic complications. The multiple effects of ECMO include inflammatory response on contact with the circuit; hemolysis acquired von Willebrand syndrome likely affects the function of red blood cells (RBC) and platelets. The aim of this prospective observational study was to analyze RBC aggregation and elongation (deformability) and platelet aggregation in the first week of ECMO. Sixteen patients were included. Blood samples were taken prior to initiation of ECMO and on days 1, 2, 3, 5, and 7. RBC aggregation and elongation were analyzed using the laser-assisted optical rotational red cell analyzer (Lorrca). Upstroke, top, and amplitude as indices of aggregation showed significant time effects. RBC elongation was not affected at low shear stress. At high shear stress there was an increase in the elongation index at day 2 (p = 0.004), followed by a decrease. Platelet function was analyzed using multiple electrode aggregometry (Multiplate®). In pairwise comparison in the days 1–7 to the value prior to ECMO there was no significant difference in platelet aggregation by any of the three agonists (ADP p = 0.61; TRAP p = 0.77; Ristocetin p = 0.25). This implies that the rheology of RBCs seemed to be more affected by ECMO than platelets. Especially the red blood cell deformability continues to decline at higher shear stress.

24 January 2024 in Transplantation Direct
Verified
Journal Article
Open access
BLBianca Lascaris
Bianca Lascaris
RHRoland Hoffmann
Roland Hoffmann
MNMaarten W.N. Nijsten
Maarten W.N. Nijsten
RPRobert Porte
Robert Porte
VMVincent E. de Meijer
Vincent E. de Meijer
Background.: Normothermic machine perfusion (NMP) is used to preserve and test donor livers before transplantation. During NMP, the liver is metabolically active and produces waste products, which are released into the perfusate. In this study, we describe our simplified and inexpensive setup that integrates continuous renal replacement therapy (CRRT) with NMP for up to 7 d. We also investigated if the ultrafiltrate could be used for monitoring perfusate concentrations of small molecules such as glucose and lactate. Methods.: Perfusate composition (urea, osmolarity, sodium, potassium, chloride, calcium, magnesium, phosphate, glucose, and lactate) was analyzed from 56 human NMP procedures without CRRT. Next, in 6 discarded human donor livers, CRRT was performed during NMP by integrating a small dialysis filter (0.2 m2) into the circuit to achieve continuous ultrafiltration combined with continuous fluid substitution for up to 7 d. Results.: Within a few hours of NMP without CRRT, a linear increase in osmolarity and concentrations of urea and phosphate to supraphysiological levels was observed. After integration of CRRT into the NMP circuit, the composition of the perfusate was corrected to physiological values within 12 h, and this homeostasis was maintained during NMP for up to 7 d. Glucose and lactate levels, as measured in the CRRT ultrafiltrate, were strongly correlated with perfusate levels (r = 0.997, P < 0.001 and r = 0.999, P < 0.001, respectively). Conclusions.: The integration of CRRT into the NMP system corrected the composition of the perfusate to near-physiological values, which could be maintained for up to 7 d. The ultrafiltrate can serve as an alternative to the perfusate to monitor concentrations of small molecules without potentially compromising sterility.

1 October 2021 in Perfusion
Verified
Journal Article
Open access
PDF file
RHRoland Hoffmann
Roland Hoffmann
SHSandra Horsten
Sandra Horsten
MMMassimo A Mariani
Massimo A Mariani
AVAdrianus J de Vries
Adrianus J de Vries
Introduction: The Activated Clotting Time (ACT) is commonly used to manage anticoagulation during cardiac surgery. The aim of this study was to compare the older manually operated Hemochron® Response and the automated Hemochron® Signature Elite. Methods: In this observational study the clinically relevant differences of both devices were investigated simultaneously, using duplicate measurements, in 29 patients who underwent a Coronary Artery Bypass Grafting (CABG) or Aortic Valve Replacement (AVR) in order to determine reliability, bias, and to detect which method has the lowest variation. Blood samples were obtained from the arterial line prior to surgery, after administration of 300 IU/kg heparin, 5 minutes after initiation of cardiopulmonary bypass and successively every 30 minutes, and after protamine administration. Results: A total of 202 measurements were performed. Of these 10 measurements were out of range in the Response and 9 in the Elite. About 27 single unstable magnet errors were seen in the Response versus no measurement errors in the Elite. No statistically significant differences between the Response (p = 0.22, Wilcoxon rank) and Elite (p = 0.064) duplicates were observed. The Response values were consistently higher during heparinization than the Elite measurements (p = 0.002, repeated measurements) with an average positive bias of around 56 seconds during heparinization (Bland-Altman). Overall, the coefficient of variation (CoV) increased during heparinization. Conclusion: The Elite was more reliable, but the variation was higher for the Elite than the Response. The observed positive bias in the Response compared to the Elite could affect heparin administration during surgery making the two systems not interchangeable.

1 April 2015 in Radiotherapy and Oncology
Verified
Journal Article
Open access
MGM.W. Van Gisbergen
M.W. Van Gisbergen
AVA.M. Voets
A.M. Voets
RHRoland Hoffmann
Roland Hoffmann
RBR. Biemans
R. Biemans
HSH.J.M. Smeets
H.J.M. Smeets
PLP. Lambin
P. Lambin