Robert Porte

Prof. Dr. Robert Porte

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2021 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
RRRianne van Rijn
Rianne van Rijn
ISIvo J. Schurink
Ivo J. Schurink
YVYvonne de Vries
Yvonne de Vries
ABAad P. van Den Berg
Aad P. van Den Berg
MCMiriam Cortes Cerisuelo
Miriam Cortes Cerisuelo
RPRobert Porte
Robert Porte
Transplantation of livers obtained from donors after circulatory death is associated with an increased risk of nonanastomotic biliary strictures. Hypothermic oxygenated machine perfusion of livers may reduce the incidence of biliary complications, but data from prospective, controlled studies are limited. In this multicenter, controlled trial, we randomly assigned patients who were undergoing transplantation of a liver obtained from a donor after circulatory death to receive that liver either after hypothermic oxygenated machine perfusion (machine-perfusion group) or after conventional static cold storage alone (control group). The primary end point was the incidence of nonanastomotic biliary strictures within 6 months after transplantation. Secondary end points included other graft-related and general complications. A total of 160 patients were enrolled, of whom 78 received a machine-perfused liver and 78 received a liver after static cold storage only (4 patients did not receive a liver in this trial). Nonanastomotic biliary strictures occurred in 6% of the patients in the machine-perfusion group and in 18% of those in the control group (risk ratio, 0.36; 95% confidence interval [CI], 0.14 to 0.94; P=0.03). Postreperfusion syndrome occurred in 12% of the recipients of a machine-perfused liver and in 27% of those in the control group (risk ratio, 0.43; 95% CI, 0.20 to 0.91). Early allograft dysfunction occurred in 26% of the machine-perfused livers, as compared with 40% of control livers (risk ratio, 0.61; 95% CI, 0.39 to 0.96). The cumulative number of treatments for nonanastomotic biliary strictures was lower by a factor of almost 4 after machine perfusion, as compared with control. The incidence of adverse events was similar in the two groups. Hypothermic oxygenated machine perfusion led to a lower risk of nonanastomotic biliary strictures following the transplantation of livers obtained from donors after circulatory death than conventional static cold storage. (Funded by Fonds NutsOhra; DHOPE-DCD ClinicalTrials.gov number, NCT02584283.)

6 March 2013 in American Journal of Transplantation
Verified
Journal Article
Open access
PDF file
SDS. Op Den Dries
S. Op Den Dries
NKN. Karimian
N. Karimian
MSM. E. Sutton
M. E. Sutton
AWA. C. Westerkamp
A. C. Westerkamp
MNM. W. N. Nijsten
M. W. N. Nijsten
RPRobert Porte
Robert Porte
In contrast to traditional static cold preservation of donor livers, normothermic machine perfusion may reduce preservation injury, improve graft viability and potentially allows ex vivo assessment of graft viability before transplantation. We have studied the feasibility of normothermic machine perfusion in four discarded human donor livers. Normothermic machine perfusion consisted of pressure and temperature controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion for 6 h. Two hollow fiber membrane oxygenators provided oxygenation of the perfusion fluid. Biochemical markers in the perfusion fluid reflected minimal hepatic injury and improving function. Lactate levels decreased to normal values, reflecting active metabolism by the liver (mean lactate 10.0 ± 2.3 mmol/L at 30 min to 2.3 ± 1.2 mmol/L at 6 h). Bile production was observed throughout the 6 h perfusion period (mean rate 8.16 ± 0.65 g/h after the first hour). Histological examination before and after 6 h of perfusion showed well‐preserved liver morphology without signs of additional hepatocellular ischemia, biliary injury or sinusoidal damage. In conclusion, this study shows that normothermic machine perfusion of human donor livers is technically feasible. It allows assessment of graft viability before transplantation, which opens new avenues for organ selection, therapeutic interventions and preconditioning.

10 April 2017 in British Journal of Surgery
Verified
Journal Article
Open access
PDF file
RRR. van Rijn
R. van Rijn
NKN. Karimian
N. Karimian
AMA. P. M. Matton
A. P. M. Matton
LBL. C. Burlage
L. C. Burlage
AWA. C. Westerkamp
A. C. Westerkamp
RPRobert Porte
Robert Porte
Experimental studies have suggested that end-ischaemic dual hypothermic oxygenated machine perfusion (DHOPE) may restore hepatocellular energy status and reduce reperfusion injury in donation after circulatory death (DCD) liver grafts. The aim of this prospective case–control study was to assess the safety and feasibility of DHOPE in DCD liver transplantation. In consecutive DCD liver transplantations, liver grafts were treated with end-ischaemic DHOPE. Outcome was compared with that in a control group of DCD liver transplantations without DHOPE, matched for donor age, donor warm ischaemia time, and recipient Model for End-stage Liver Disease (MELD) score. All patients were followed for 1 year. Ten transplantations involving liver grafts treated with DHOPE were compared with 20 control procedures. There were no technical problems. All 6-month and 1-year graft and patient survival rates were 100 per cent in the DHOPE group. Six-month graft survival and 1-year graft and patient survival rates in the control group were 80, 67 and 85 per cent respectively. During DHOPE, median (i.q.r.) hepatic adenosine 5′-triphosphate (ATP) content increased 11-fold, from 6 (3–10) to 66 (42–87) µmol per g protein (P = 0·005). All DHOPE-preserved livers showed excellent early function. At 1 week after transplantation peak serum alanine aminotransferase (ALT) and bilirubin levels were twofold lower in the DHOPE group than in the control group (ALT: median 966 versus 1858 units/l respectively, P = 0·006; bilirubin: median 1·0 (i.q.r. 0·7–1·4) versus 2·6 (0·9–5·1) mg/dl, P = 0·044). None of the ten DHOPE-preserved livers required retransplantation for non-anastomotic biliary stricture, compared with five of 20 in the control group (P = 0·140). This clinical study of end-ischaemic DHOPE in DCD liver transplantation suggests that the technique restores hepatic ATP, reduces reperfusion injury, and is safe and feasible. RCTs with larger numbers of patients are warranted to assess the efficacy in reducing post-transplant biliary complications.

1 June 2014 in Journal of Hepatology
Verified
Journal Article
Closed access
SDSanna Op Den Dries
Sanna Op Den Dries
AWAndrie C. Westerkamp
Andrie C. Westerkamp
NKNegin Karimian
Negin Karimian
AGAnnette S.H. Gouw
Annette S.H. Gouw
BBBote G. Bruinsma
Bote G. Bruinsma
RPRobert Porte
Robert Porte

1 July 2019 in Transplantation
Verified
Journal Article
Open access
AMAlix P.M. Matton
Alix P.M. Matton
YVYvonne de Vries
Yvonne de Vries
LBLaura C. Burlage
Laura C. Burlage
RRRianne van Rijn
Rianne van Rijn
MFMasato Fujiyoshi
Masato Fujiyoshi
RPRobert Porte
Robert Porte
Background.: Ex situ normothermic machine perfusion (NMP) can be used to assess viability of suboptimal donor livers before implantation. Our aim was to assess the diagnostic accuracy of bile biochemistry for the assessment of bile duct injury (BDI). Methods.: In a preclinical study, 23 human donor livers underwent 6 hours of end-ischemic NMP to determine biomarkers of BDI. Livers were divided into groups with low or high BDI, based on a clinically relevant histological grading system. During NMP, bile was analyzed biochemically and potential biomarkers were correlated with the degree of BDI. Receiver operating characteristics curves were generated to determine optimal cutoff values. For clinical validation, identified biomarkers were subsequently included as viability criteria in a clinical trial (n = 6) to identify transplantable liver grafts with low BDI. Results.: Biliary bicarbonate and pH were significantly higher and biliary glucose was significantly lower in livers with low BDI, compared with high BDI. The following cutoff values were associated with low BDI: biliary bicarbonate greater than 18 mmol/L (P = 0.002), biliary pH greater than 7.48 (P = 0.019), biliary glucose less than 16 mmol/L (P = 0.013), and bile/perfusate glucose ratio less than 0.67 (P = 0.013). In the clinical trial, 4 of 6 livers met these criteria and were transplanted, and none developed clinical evidence of posttransplant cholangiopathy. Conclusions.: Biliary bicarbonate, pH, and glucose during ex situ NMP of liver grafts are accurate biomarkers of BDI and can be easily determined point of care, making them suitable for the pretransplant assessment of bile duct viability. This may improve graft selection and decrease the risk of posttransplant cholangiopathy.

19 January 2023 in Journal of Hepatology
Verified
Journal Article
Open access
ASAndrea Schlegel
Andrea Schlegel
MMMatteo Mueller
Matteo Mueller
XMXavier Muller
Xavier Muller
JEJanina Eden
Janina Eden
RPRebecca Panconesi
Rebecca Panconesi
PDPhilipp Dutkowski
Philipp Dutkowski
Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.