The energy monitoring of heritage buildings has, to date, been governed by methodologies and standards that have been defined in terms of sensors that record scalar magnitudes and that are placed in specific positions in the scene, thus recording only some of the values sampled in that space. In this paper, however, we present an alternative to the aforementioned technologies in the form of new sensors based on 3D computer vision that are able to record dense thermal information in a three-dimensional space. These thermal computer vision-based technologies (3D-TCV) entail a revision and updating of the current building energy monitoring methodologies. This paper provides a detailed definition of the most significant aspects of this new extended methodology and presents a case study showing the potential of 3D-TCV techniques and how they may complement current techniques. The results obtained lead us to believe that 3D computer vision can provide the field of building monitoring with a decisive boost, particularly in the case of heritage buildings.
This paper describes the influence of thermal parameters—conductivity, transmittance, and thermal mass—in the estimation of comfort and energy demand of a building with rammed earth walls, and consequently, the compliance with standards. It is known that nominal design data does not match in situ measured values, especially in traditionally constructed buildings. We have therefore monitored a room in a building with rammed earth walls, designed a computerised model, and compared four different alternatives where we have changed the value for the thermal conductivity (in situ vs. estimated) and the consideration of thermal mass. When we then analyse the compliance with the Spanish energy saving code, using measured values would result in lower differences with the standards’ limits and even comply with the global thermal transmittance (K-value) requirement. This would mean a more realistic approach to the restoration of traditional buildings leading to the use of thinner and more suitable insulation and retrofitting systems, encouraging the use of rammed earth in new buildings, and therefore reducing the carbon footprint due to materials used in construction. Results show that the building model that uses in situ values and considers thermal mass (S1) is closer to reality when assessing thermal comfort. Finally, using nominal data would result in requiring 43% more energy in the selected winter period and 102% more energy in the selected summer period to keep the same comfort conditions as in the alternative where measured values are used.
This paper studies how to create precise 3D thermal maps of building interiors by correcting the raw apparent temperature values yielded by the thermal cameras. This matter has not, to date, been dealt with in the literature, which leads us to conclude that the current methodologies that obtain thermal point clouds are incomplete and imprecise. Without a suitable correction, any further energy parameter calculation obtained from the thermal point cloud is incorrect. This paper presents a method that deals with important aspects to be corrected, such as the repeatability of thermal cameras, the use of the true emissivity of the materials sensed, and the inclusion of the reflected radiant energy caused by the environment. The method has been successfully tested in several indoor scenes using a thermal scanning platform. The results show that significant corrections of up to 8% of the raw temperature values must be carried out in the final thermal model, thus justifying the need for the correction. As an application of the method, an empirical calculation and a comparison of transmittances with and without temperature corrections are presented at the end of the paper. In this case, the relative errors with respect to the average nominal U-value decrease from 94% to 11%. The general conclusion is that precise calculations of energy parameters in which infrared cameras are involved must take these corrections to temperature into account.
The use of point clouds in architecture and civil engineering has, to date, been limited almost exclusively to functional geometric features. Nevertheless, hardly any works have attempted to process and explore 3D thermal models for buildings. This paper presents a method for the visualisation and exploration of 3D thermal models (3D-T) of building interiors. A 3D-T model consists of a thermal point cloud, which has been generated with a 3D thermal-scanner platform. Given a 3D-T of a building at a specific time, the user can visualise and navigate through different room models and each room can, in turn, be segmented into its architectonic components (walls, ceilings and floors), from which thermal orthoimages can be generated. When the building is sensed at different times, a 3D temporal-thermal (3D-TT) model is integrated. The temporal-thermal evolution of these structural components, along with selected zones of them, can then be analysed by performing a new type of thermal characterisation. This method has successfully been tested using real building-related data.
The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.