Francisco Javier Castilla Pascual

Dr. Francisco Javier Castilla Pascual

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Behnam MobarakiBehnam Mobaraki
Behnam Mobaraki
FLFidel Lozano
Fidel Lozano
RSROCIO PORRAS SORIANO
ROCIO PORRAS SORIANO
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
In recent years, many scholars have dedicated their research to the development of low-cost sensors for monitoring of various parameters. Despite their high number of applications, the state of the art related to low-cost sensors in building monitoring has not been addressed. To fill this gap, this article presents a systematic review, following well-established methodology, to analyze the state of the art in two aspects of structural and indoor parameters of buildings, in the SCOPUS database. This analysis allows to illustrate the potential uses of low-cost sensors in the building sector and addresses the scholars the preferred communication protocols and the most common microcontrollers for installation of low-cost monitoring systems. In addition, special attention is paid to describe different areas of the two mentioned fields of building monitoring and the most crucial parameters to be monitored in buildings. Finally, the deficiencies in line with limited number of studies carried out in various fields of building monitoring are overviewed and a series of parameters that ought to be studied in the future are proposed.

15 June 2023 in Heliyon
Verified
Journal Article
Open access
Behnam MobarakiBehnam Mobaraki
Behnam Mobaraki
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
AGArturo Martínez García
Arturo Martínez García
MMMIGUEL ANGEL MELLADO MASCARAQUE
MIGUEL ANGEL MELLADO MASCARAQUE
BFBORJA FRUTOS
BORJA FRUTOS
CACarmen Alonso
Carmen Alonso
The non-destructive thermal characterization of building envelopes relies significantly on various factors such as climate conditions, monitoring devices used, indoor environment, and conditioning systems. In the case of both the temperature-based method (TBM) and heat flux meter (HFM) approaches, U-value is determined considering the ideal condition of steady state. However, it is challenging to accurately define the true thermal condition of buildings when monitoring is affected by inherent uncertainties of the chosen approach and inadequate instrumentation of building envelopes. This paper presents the outcomes of an experimental campaign, that aimed to evaluate the impact of incorrectly positioned exterior sensors, on the precision of U-value measurements. This study simultaneously employed the TBM and HFM approaches. To enhance the accuracy of the results, rigorous outlier detection and statistical analysis were employed on the data collected from three autonomous monitoring systems. The findings of this study revealed that the applied data analysis yielded more satisfactory results for the TBM approach compared to HFM. However, regardless of the approach used, the effectiveness of outlier detection relied heavily on the accuracy of the monitoring systems. When removing an individual outlier, the monitoring systems characterized with higher accuracies provided U-values that were closer to the theoretical values, than less accurate ones.

8 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Behnam MobarakiBehnam Mobaraki
Behnam Mobaraki
Seyedmilad KomarizadehaslSeyedmilad Komarizadehasl
Seyedmilad Komarizadehasl
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
Jose Antonio Lozano-GalantJose Antonio Lozano-Galant
Jose Antonio Lozano-Galant
In structures with reduced monitoring budgets, the high cost of commercial metering devices is always an obstacle for monitoring structural health. This might be an issue when temperatures must be measured for both structural and environmental reasons. To fill this gap, in this paper, a novel monitoring system is proposed for the accurate measurement of indoor temperature in buildings. This protocol is characterized by its generality, as it can be easily adapted to measure any structural or environmental parameters on site. The proposed monitoring system uses from one to eight low-cost sensors to obtain multiple measurements of the ambient temperatures. The accuracy ranges of the developed monitoring systems with different numbers of sensors are statistically analysed. The results indicate that the discrepancy of the measurements decreases with the increase in the number of sensors, as the maximum standard deviation of 10 sensors (0.42) decreases to 0.32 and 0.27 for clusters of 20 and 30 sensors, respectively.

18 May 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Behnam MobarakiBehnam Mobaraki
Behnam Mobaraki
Seyedmilad KomarizadehaslSeyedmilad Komarizadehasl
Seyedmilad Komarizadehasl
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
Jose Antonio Lozano-GalantJose Antonio Lozano-Galant
Jose Antonio Lozano-Galant
RSROCIO PORRAS SORIANO
ROCIO PORRAS SORIANO
Owing to the high energy consumption in the building sector, appraising the thermal performance of building envelopes is an increasing concern. Recently, a few in situ methodologies to diagnose the thermal parameters of buildings have been considered. However, because of their limitations such as low accuracy, limited number of measurements, and the high cost of monitoring devices, researchers are seeking a new alternative. In this study, a novel hyper-efficient Arduino transmittance-meter was introduced to overcome these limitations and determine the thermal parameters of building envelopes. Unlike conventional methodologies, the proposed transmittance-meter is based on synchronized measurements of different parameters necessary to estimate the transmittance parameter. To verify the applicability of the transmittance-meter, an experimental study was conducted wherein a temperature-controlled box model was thermally monitored, and the outputs of the transmittance-meter employed were compared with those captured by a commercial device. The results revealed a high level of reduction in cost and a low range of difference compared with the latter, thereby validating the applicability of the proposed thermal monitoring system.

31 March 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
ARAmanda Ramón-Constantí
Amanda Ramón-Constantí
Antonio AdanAntonio Adan
Antonio Adan
ATA. Trenado
A. Trenado
DFD. Fuentes
D. Fuentes
3D computer vision techniques are now required for the virtual reconstruction of ancient buildings and monuments in urban environments. In this paper, we include a new subfield within the broad field of Urban Heritage that we denominate as Rural Heritage (RH), and which is focused on recovering 3D models of small buildings and facilities of significance in rural environments. We, therefore, present a multi-sensory approach whose objective is to create complete architectural documentation of the dovecotes in an extended region of central Spain. This kind of aviary construction was very common in Spanish rural environments during the 19th century and the first half of the 20th century and is representative of an RH building. Sensory fusion was developed using color cameras, 3D terrestrial laser scanners, and photogrammetric techniques with Unmanned Aerial Vehicles (UAV) and achieves precise indoor and outdoor 3D models. The sensory fusion here also refers to the fact that the information coming from different sensors is integrated into a common documentation framework. A total of 80 dovecotes have been referenced and made available to the public in open access resources. The successful results and applicability of our method lead us to believe that the current documentation and the safeguard technologies in the RH field should evolve towards the use of these 3D computer vision techniques.

1 January 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
PBPablo Bellido-Montesinos
Pablo Bellido-Montesinos
FLFidel Lozano
Fidel Lozano
FPFrancisco Javier Castilla Pascual
Francisco Javier Castilla Pascual
Jose Antonio Lozano-GalantJose Antonio Lozano-Galant
Jose Antonio Lozano-Galant