Byungyun Lee

Prof. Byungyun Lee


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
SRSun-Young Rieh
Sun-Young Rieh
BLByungyun Lee
Byungyun Lee
JOJoonGul Oh
JoonGul Oh
TSThorsten Schuetze
Thorsten Schuetze
Santiago Porras AlvarezSantiago Porras Alvarez
Santiago Porras Alvarez
Jiyoung ParkJiyoung Park
Jiyoung Park
This paper examines the integration of sustainability principles into architectural education programs at South Korean Universities that have been accredited by the Korea Architectural Accrediting Board (KAAB). Accreditation requires the successful implementation of 30 so-called Student Performance Criteria (SPCs). Similar to recent improvements to international architectural education, different principles of sustainability have been successfully implemented by the KAAB. This paper identifies eight sustainability-related SPCs that can be utilized to teach sustainability. The analysis of 48 accredited five-year architectural education program curricula in South Korea has revealed which sustainability-related SPCs are addressed each semester. Furthermore, the average number of credits per sustainability-related SPC in different course types, such as theory courses and design studios, has been identified. Theory courses with an emphasis on sustainability education have been defined as sustainability core courses. The results reveal that a majority of existing programs primarily address environmental aspects of sustainability. Furthermore, a sequential course structure analysis elucidates three main curriculum types, with different potential for integrated sustainability education in sustainability core courses and design studios: (i) sustainability core course preceding (high potential); (ii) sustainability core courses and design studio, accompanying (high potential); and (iii) sustainability core course following (low potential).

27 February 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
BLByungyun Lee
Byungyun Lee
Kinetic shading devices have recently been introduced for energy-saving and for their innovative appearance. Quantifiable research on kinetic operation systems is necessary to evaluate their applicability in a specific region. This study developed a theoretical methodology for producing an optimal positioning algorithm targeting minimizing total energy demands of kinetic shading devices; the control algorithms for hourly operation were tested through a combined analysis framework of energy performance simulations and spreadsheet analysis. Two common types of external shading devices, vertical-folding and horizontal-rotating types, were simulated in three Asian cities with different climate conditions. Automatic kinetic operation with a consequential dimming control was simulated on the east, south and west facade of an office building, selecting the optimal position every hour based on total energy demand for heating, cooling, and lighting. Comparative simulation analyses for kinetic operation and fixed shading demonstrated that the energy saving potential of fixed shading was greater than that of kinetic operation shading. Kinetic operation was the most applicable in Seoul, where seasonal optimal operation was required for both types of kinetic shadings. In Abu Dhabi and Hanoi, cooling and lighting energy demands were balanced every hour through kinetic operation. Rotating-type kinetic operation in these two regions resulted in better energy-saving performance. The operation frequency pattern of rotating-type kinetic shading provided more active operation and consequent outperformance over the folding-type.

10 February 2015 in Sustainability
Verified
Journal Article
Open access
PDF file
DLDongseok Lee
Dongseok Lee
JJJae Hun Jo
Jae Hun Jo
SKSung-Han Koo
Sung-Han Koo
BLByungyun Lee
Byungyun Lee
The energy performance of buildings depends on how effectively the building envelope responds to climate. Architects, therefore, need to design building envelopes with the consideration of local climate characteristics in the early design stage. Simplified formulas were used that evaluate the heating and cooling energy demand of building envelopes, which were applied to a model building with envelope and climate properties according to eight climate zones. Two climate indices, P and S, were developed. P enables the comparison of the heating and cooling energy demand of building envelopes, and S is for comparing the solar heat gain during heating and cooling seasons to review the feasibility of installing shading devices. The physical properties of envelopes were set differently according to the requirements in each climate zone proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. Using local climate data, the P and S of 24 cities over eight climate zones in the United States were derived, which can be used to evaluate the heating and cooling energy characteristics of envelopes. The indices not only enable users to understand the characteristics of the local climate conditions in a simple manner, but also to carry out quantitative assessments on whether shading devices are feasible and, if so, what type is recommended.