Alejandro Moreno-Rangel

Dr. Alejandro Moreno-Rangel

Architecture, University of Strathclyde, Glasgow, Glasgow City, UK
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
MMMuhammad Norhaffis Mustafa
Muhammad Norhaffis Mustafa
MAMuhammad Amirul Aizat Mohd Abdah
Muhammad Amirul Aizat Mohd Abdah
ANArshid Numan
Arshid Numan
Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
ARAmr Radwan
Amr Radwan
MKMohammad Khalid
Mohammad Khalid

9 May 2018 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
Tim SharpeTim Sharpe
Tim Sharpe
FMFilbert Musau
Filbert Musau
GMGrainne McGill
Grainne McGill
Measurements of temporal and spatial changes to indoor contaminant concentrations are vital to understanding pollution characteristics. Whilst scientific instruments provide high temporal resolution of indoor pollutants, their cost and complexity make them unfeasible for large-scale projects. Low-cost monitors offer an opportunity to collect high-density temporal and spatial data in a broader range of households. This paper presents a user study to assess the precision, accuracy, and usability of a low-cost indoor air quality monitor in a residential environment to collect data about the indoor pollution. Temperature, relative humidity, total volatile organic compounds (tVOC), carbon dioxide (CO2) equivalents, and fine particulate matter (PM2.5) data were measured with five low-cost (Foobot) monitors and were compared with data from other monitors reported to be scientifically validated. The study found a significant agreement between the instruments with regard to temperature, relative humidity, total volatile organic compounds, and fine particulate matter data. Foobot CO2 equivalent was found to provide misleading CO2 levels as indicators of ventilation. Calibration equations were derived for tVOC, CO2, and PM2.5 to improve sensors' accuracy. The data were analysed based on the percentage of time pollutant levels that exceeded WHO thresholds. The performance of low-cost monitors to measure total volatile organic compounds and particulate matter 2.5 µm has not been properly addressed. The findings suggest that Foobot is sufficiently accurate for identifying high pollutant exposures with potential health risks and for providing data at high granularity and good potential for user or scientific applications due to remote data retrieval. It may also be well suited to remote and larger-scale studies in quantifying exposure to pollutants.

Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
Tim SharpeTim Sharpe
Tim Sharpe
GMGrainne McGill
Grainne McGill
FMFilbert Musau
Filbert Musau
Indoor air quality (IAQ) is a critical consideration in airtight buildings that depend on mechanical ventilation, such as those constructed to the Passivhaus standard. While previous reviews of IAQ on Passivhaus-certified buildings foccused on offices, this study examines residential buildings. A summary of data collection methods and pollutant concentrations is presented, followed by a critical discussion of the impact of Passivhaus design strategies on IAQ. This review indicates that IAQ in Passivhaus-certified dwellings is generally better than in conventional homes, but both occupant behaviour and pollution from outdoor sources play a significant role in indoor concentrations. Moreover, there are differences in data collection and reporting methods. Many of the available studies depend on short-term IAQ monitoring of less than two weeks, making it difficult to determine the longer impact of housing design on IAQ and occupants’ well-being. There is also a lack of studies from non-European countries. Future research should focus on investigating associations between IAQ and Passivhaus design strategies in hot and humid climates, where evidence is particularly lacking. Further effort is also required to investigate potential links between occupant’s perception of IAQ and physical exposure to indoor pollution. Finally, the lack of homogeneous monitoring and reporting methods for IAQ studies needs to be addressed.

11 December 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
TRTaehyun Roh
Taehyun Roh
Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
JBJuha Baek
Juha Baek
AOAlexander Boakye Obeng
Alexander Boakye Obeng
NHNishat Tasnim Hasan
Nishat Tasnim Hasan
Genny CarrilloGenny Carrillo
Genny Carrillo
Indoor air quality (IAQ) has a substantial impact on public health. Since the beginning of the COVID-19 pandemic, more employees have worked remotely from home to minimize in-person contacts. This pilot study aims to measure the difference in workplace IAQ before and during the pandemic and its impact on employees’ health. The levels of fine particulate matter (PM2.5) and total volatile organic chemicals (tVOC) were measured in the employees’ offices before the COVID-19 pandemic and at homes while working from home during the pandemic using Foobot air monitors. The frequencies of six sick building syndrome (SBS) symptoms were evaluated at each period of monitoring. The result showed PM2.5 levels in households while working from home were significantly higher than in offices while working at the office for all participants (p < 0.05). The PM2.5 levels in all households exceeded the health-based annual mean standard (12 µg/m3), whereas 90% of offices were in compliance. The tVOC levels were all below the standard (500 µg/m3). We also found a higher frequency of SBS symptoms were observed while working from home as the IAQ was worse at home. This study suggested that working from home might have a detrimental health impact due to poor IAQ and providing interventions to remote employees should be considered.

22 December 2020 in Encyclopedia
Verified
Journal Article
Open access
PDF file
Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
Passivhaus or Passive House buildings are low-energy buildings in which the design is driven by quality and comfort, hence achieving acceptable levels of comfort through post-heating or post-cooling of fresh air. Additionally, Passivhaus building design follows the Passivhaus design criteria, as described in the Passive House Planning Package (PHPP). This article aims to introduce the Passivhaus background, development, and basic design principles. Finally, it also presents a brief description of the performance of Passivhaus buildings.

3 August 2020 in Journal of Environmental and Public Health
Verified
Journal Article
Open access
PDF file
Alejandro Moreno-RangelAlejandro Moreno-Rangel
Alejandro Moreno-Rangel
JBJuha Baek
Juha Baek
TRTaehyun Roh
Taehyun Roh
XXXiaohui Xu
Xiaohui Xu
Genny CarrilloGenny Carrillo
Genny Carrillo
Few studies have investigated household interventions to enhance indoor air quality (IAQ) and health outcomes in relatively low-income communities. This study aims to examine the impact of the combined intervention with asthma education and air purifier on IAQ and health outcomes in the US-Mexico border area. An intervention study conducted in McAllen, Texas, between June and November 2019 included 16 households having children with asthma. The particulate matter (PM2.5) levels were monitored in the bedroom, kitchen, and living room to measure the IAQ for 7 days before and after the intervention, respectively. Multiple surveys were applied to evaluate changes in children's health outcomes. The mean PM2.5 levels in each place were significantly improved. Overall, they significantly decreased by 1.91 μg/m3 on average (p<0.05). All surveys showed better health outcomes; particularly, quality of life for children was significantly improved (p<0.05). This pilot study suggests that the combined household intervention might improve IAQ in households and health outcomes for children with asthma and reduce health disparities in low-income communities. Future large-scale studies are needed to verify the effectiveness of this household intervention to improve IAQ and asthma management.