Measurements of temporal and spatial changes to indoor contaminant concentrations are vital to understanding pollution characteristics. Whilst scientific instruments provide high temporal resolution of indoor pollutants, their cost and complexity make them unfeasible for large-scale projects. Low-cost monitors offer an opportunity to collect high-density temporal and spatial data in a broader range of households. This paper presents a user study to assess the precision, accuracy, and usability of a low-cost indoor air quality monitor in a residential environment to collect data about the indoor pollution. Temperature, relative humidity, total volatile organic compounds (tVOC), carbon dioxide (CO2) equivalents, and fine particulate matter (PM2.5) data were measured with five low-cost (Foobot) monitors and were compared with data from other monitors reported to be scientifically validated. The study found a significant agreement between the instruments with regard to temperature, relative humidity, total volatile organic compounds, and fine particulate matter data. Foobot CO2 equivalent was found to provide misleading CO2 levels as indicators of ventilation. Calibration equations were derived for tVOC, CO2, and PM2.5 to improve sensors' accuracy. The data were analysed based on the percentage of time pollutant levels that exceeded WHO thresholds. The performance of low-cost monitors to measure total volatile organic compounds and particulate matter 2.5 µm has not been properly addressed. The findings suggest that Foobot is sufficiently accurate for identifying high pollutant exposures with potential health risks and for providing data at high granularity and good potential for user or scientific applications due to remote data retrieval. It may also be well suited to remote and larger-scale studies in quantifying exposure to pollutants.
Indoor air quality (IAQ) is a critical consideration in airtight buildings that depend on mechanical ventilation, such as those constructed to the Passivhaus standard. While previous reviews of IAQ on Passivhaus-certified buildings foccused on offices, this study examines residential buildings. A summary of data collection methods and pollutant concentrations is presented, followed by a critical discussion of the impact of Passivhaus design strategies on IAQ. This review indicates that IAQ in Passivhaus-certified dwellings is generally better than in conventional homes, but both occupant behaviour and pollution from outdoor sources play a significant role in indoor concentrations. Moreover, there are differences in data collection and reporting methods. Many of the available studies depend on short-term IAQ monitoring of less than two weeks, making it difficult to determine the longer impact of housing design on IAQ and occupants’ well-being. There is also a lack of studies from non-European countries. Future research should focus on investigating associations between IAQ and Passivhaus design strategies in hot and humid climates, where evidence is particularly lacking. Further effort is also required to investigate potential links between occupant’s perception of IAQ and physical exposure to indoor pollution. Finally, the lack of homogeneous monitoring and reporting methods for IAQ studies needs to be addressed.
8 November 2016 in Building Research & Information
There is growing awareness of the overheating risks in new-build properties in the UK. However, this tends to be considered a problem principally for the southern regions in the UK, only becoming a serious issue in the north of England in the medium-term and in the long-term for Scotland. This notion tends to be largely predicated upon climate change predictions, differences in latitude and summer air temperatures. This paper describes the results from Building Performance Evaluation (BPE) studies over a two-year period from 26 occupied new-build homes across Scotland which demonstrated incidences of overheating. Results suggest that low-energy buildings are susceptible to overheating despite northerly latitudes, with 54% of houses studied overheating for more than six months annually, and 27% of homes overheating for less than 10% of the year. Evidence indicated that commonly used prediction tools do not appear to anticipate overheating adequately. This paper maps common overheating causes due to design and the role of occupants, identifying the risks due to the regulatory system, prediction and procurement processes, and design and construction. A common finding was that design and occupancy factors appear to have a greater impact on overheating more than location and climatic factors.
27 November 2013 in Building Services Engineering Research & Technology
Building more air-tight dwellings is having a deleterious impact on indoor air quality. In a range of recently completed dwellings CO 2 concentrations were measured in occupied bedrooms at unacceptable concentrations (occupied mean peak of 2317 ppm and a time weighted average of 1834 ppm, range 480–4800 ppm). Such high levels confirm that air-tight dwellings with only trickle ventilators as the ‘planned’ ventilation strategy do not meet the standards demanded by the Building Regulations. Reducing ventilation rates to improve energy efficiency and lower carbon emissions, without providing a planned and effective ventilation strategy is likely to result in a more toxic and hazardous indoor environment, with concurrent and significant negative long-term and insidious impacts on public health. Furthermore, the methodology underpinning the current regulations cannot be considered as creditable. While the complexity around numerical modeling often leads to conclusions based upon simplistic and unrealistic assumptions around all doors in a dwelling being open and trickle ventilators being unobstructed, this paper demonstrates that in ‘real life’ situations, this is not the case and could lead to significant risks of under ventilation. This is particularly the case when standards and guidance are based upon theoretically modeled scenarios that are not representative of real-life operation. The consequences of this are important in terms of the likely negative impacts on occupant health.
In the context of increasingly airtight homes, there is currently little known about the type and diversity of microorganisms in the home, or factors that could affect their abundance, diversity and nature. In this study, we examined the type and prevalence of cultivable microorganisms at eight different sites in 100 homes of older adults located in Glasgow, Scotland. The microbiological sampling was undertaken alongside a household survey that collated information on household demographics, occupant behaviour, building characteristics, antibiotic use and general health information. Each of the sampled sites revealed its own distinct microbiological character, in both species and number of cultivable microbes. While some potential human pathogens were identified, none were found to be multidrug resistant. We examined whether the variability in bacterial communities could be attributed to differences in building characteristics, occupant behaviour or household factors. Sampled sites furnished specific microbiological characteristics which reflected room function and touch frequency. We found that homes that reported opening windows more often were strongly associated with lower numbers of Gram-negative organisms at indoor sites (p < 0.0001). This work offers one of the first detailed analysis of cultivable microbes in homes of older adults and their relationship with building and occupancy related factors, in a UK context.