Hussain Almohiy

Dr. Hussain Almohiy

Radiological SciencesVice Dean College of Applied Medical Sciences

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in World Journal of Radiology
Verified
Journal Article
Open access
HAHussain Almohiy
Hussain Almohiy
Paediatric computed tomography radiation dose: A review of the global dilemma

24 February 2023 in Molecules
Verified
Journal Article
Open access
PDF file
SJShubham Joshi
Shubham Joshi
SASarah Mohammed Allabun
Sarah Mohammed Allabun
Stephen A OjoStephen A Ojo
Stephen A Ojo
MAMohammed Alqahtani
Mohammed Alqahtani
Piyush Kumar ShuklaPiyush Kumar Shukla
Piyush Kumar Shukla
HAHussain Almohiy
Hussain Almohiy
Mesenchymal stem cells (MSCs) have newly developed as a potential drug delivery system. MSC-based drug delivery systems (MSCs-DDS) have made significant strides in the treatment of several illnesses, as shown by a plethora of research. However, as this area of research rapidly develops, several issues with this delivery technique have emerged, most often as a result of its intrinsic limits. To increase the effectiveness and security of this system, several cutting-edge technologies are being developed concurrently. However, the advancement of MSC applicability in clinical practice is severely hampered by the absence of standardized methodologies for assessing cell safety, effectiveness, and biodistribution. In this work, the biodistribution and systemic safety of MSCs are highlighted as we assess the status of MSC-based cell therapy at this time. We also examine the underlying mechanisms of MSCs to better understand the risks of tumor initiation and propagation. Methods for MSC biodistribution are explored, as well as the pharmacokinetics and pharmacodynamics of cell therapies. We also highlight various promising technologies, such as nanotechnology, genome engineering technology, and biomimetic technology, to enhance MSC-DDS. For statistical analysis, we used analysis of variance (ANOVA), Kaplan Meier, and log-rank tests. In this work, we created a shared DDS medication distribution network using an extended enhanced optimization approach called enhanced particle swarm optimization (E-PSO). To identify the considerable untapped potential and highlight promising future research paths, we highlight the use of MSCs in gene delivery and medication, also membrane-coated MSC nanoparticles, for treatment and drug delivery.

6 July 2020 in Medical Sciences
Verified
Journal Article
Open access
PDF file
HAHaney Alsleem
Haney Alsleem
HAHussain Almohiy
Hussain Almohiy
Background: To evaluate contrast-to-noise ratio (CNR) measurements in assessing image quality, in the context of the detectability performance of low-contrast detail (LCD), in computed tomography (CT) images, since exposure to elevated ionising-type radiation is considered to present excessive carcinogenic risk, whilst also causing distress in study subjects. Methods: An LCD phantom module (CTP515) was utilised in the study. Three dissimilar contrast items were used to analyse the ramifications of the proportions of an object on the CNR. Three multidetector CT (MDCT) scanners were used, with 16-MDCT, 64-MDCT and 80-MDCT frameworks, respectively. The CT scans were recreated using three dissimilar remaking algorithms—soft, standard and lung. The effects exerted on the CNR by various remodelling algorithms, as well as the contrast of various objects along with the size of the objects, were explored. The Hounsfield units of each chosen object (one unit representing the outer portion of the object) and the background and the standard deviation of the noise parameter were quantified, and algorithms were developed using MATLAB. Results: The CNR information was greatly influenced by changing the image recreation calculations and was very much increased in the soft-tissue recreation images using 16-MDCT and 64-MDCT. The CNR information was also increased more in the optimum recreation images than in the reproduced images from the computational procedure used in the 80-MDCT. The results did not show any remarkable contrasts in the CNR values between the different object sizes. Overall, a higher kVp produced an improved CNR in all the CT scanners. In particular, there were prominent upgrades in the CNR information when the kVp was increased from 80 to 120. Higher mAs levels gave better CNR values overall, especially for greater section thicknesses. Based on the CNR estimations, the 64-MDCT provided the best correlation among the CT scanners. Conclusions: The objective LCD appraisal method, based on CNR measurements, was confirmed as being useful for checking the different impacts of kVp, mAs and section thickness on the nature of the picture. This procedure was similarly viable in assessing the impacts of the different reconstruction calculations and the different differentiation questions on the nature of the image.

7 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DNDImple Nagpal
DImple Nagpal
NANajah M. Alsubaie
Najah M. Alsubaie
BSBen Othman Sofiene
Ben Othman Sofiene
MAMohammed Alqahtani
Mohammed Alqahtani
MAMohamed Abbas
Mohamed Abbas
HAHussain Almohiy
Hussain Almohiy
Diabetic retinopathy (DR) is a complication of diabetes that affects the eyes. It occurs when high blood sugar levels damage the blood vessels in the retina, the light-sensitive tissue at the back of the eye. Therefore, there is a need to detect DR in the early stages to reduce the risk of blindness. Transfer learning is a machine learning technique where a pre-trained model is used as a starting point for a new task. Transfer learning has been applied to diabetic retinopathy classification with promising results. Pre-trained models, such as convolutional neural networks (CNNs), can be fine-tuned on a new dataset of retinal images to classify diabetic retinopathy. This manuscript aims at developing an automated scheme for diagnosing and grading DR and HR. The retinal image classification has been performed using three phases that include preprocessing, segmentation and feature extraction techniques. The pre-processing methodology has been proposed for reducing the noise in retinal images. A-CLAHE, DNCNN and Wiener filter techniques have been applied for the enhancement of images. After pre-processing, blood vessel segmentation in retinal images has been performed utilizing OTSU thresholding and mathematical morphology. Feature extraction and classification have been performed using transfer learning models. The segmented images were then classified using Modified ResNet 101 architecture. The performance for enhanced images has been evaluated on PSNR and shows better results as compared to the existing literature. The network is trained on more than 6000 images from MESSIDOR and ODIR datasets and achieves the classification accuracy of 98.72%.

20 July 2020 in Medical Sciences
Verified
Journal Article
Open access
PDF file
HAHussain Almohiy
Hussain Almohiy
KHkhalid I Hussein
khalid I Hussein
MAMohammed Alqahtani
Mohammed Alqahtani
EEElhussaien Hassan Ahmed ELSHIEKH
Elhussaien Hassan Ahmed ELSHIEKH
OLOmer Loaz
Omer Loaz
CSCharbel Saade
Charbel Saade
Computed tomography (CT) is a key imaging technique in diagnostic radiology, providing highly sensitive and specific information. While its use has increased dramatically in recent years, the quantity and associated risks of radiation from CT scans present major challenges, particularly in paediatrics. The fundamental principles of radiation protection require that radiation quantities be as low as reasonably achievable and CT use must be justified, particularly for paediatric patients. CT radiation knowledge is a key factor in optimising and minimising radiation risk. The objective of this study was to analyse knowledge level, expertise, and competency regarding CT radiation dose and its hazards in paediatrics among radiologists in Saudi Arabian hospitals. A self-reported, multiple-choice questionnaire assessed the attitudes and opinions of radiologists involved in imaging studies using ionising radiation. Among the total respondents, 65% ± 13.5% had a good comprehension of the dangers of carcinogenicity to the patient resulting from CT scans, with 80% presuming that cancer risks were elevated. However, only 48.5%, 56.5%, and 65% of the respondents were aware of specific radiation risks in head, chest, and abdominal paediatric examinations, respectively. Regular, frequent, and specific training courses are suggested to improve the fundamental knowledge of CT radiation among radiologists and other physicians.

1 September 2016 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
HAHussain Almohiy
Hussain Almohiy
EAEmadeldin Mohamed Mukhtar Alasar
Emadeldin Mohamed Mukhtar Alasar
CSCharbel Saade
Charbel Saade