Background: To evaluate contrast-to-noise ratio (CNR) measurements in assessing image quality, in the context of the detectability performance of low-contrast detail (LCD), in computed tomography (CT) images, since exposure to elevated ionising-type radiation is considered to present excessive carcinogenic risk, whilst also causing distress in study subjects. Methods: An LCD phantom module (CTP515) was utilised in the study. Three dissimilar contrast items were used to analyse the ramifications of the proportions of an object on the CNR. Three multidetector CT (MDCT) scanners were used, with 16-MDCT, 64-MDCT and 80-MDCT frameworks, respectively. The CT scans were recreated using three dissimilar remaking algorithms—soft, standard and lung. The effects exerted on the CNR by various remodelling algorithms, as well as the contrast of various objects along with the size of the objects, were explored. The Hounsfield units of each chosen object (one unit representing the outer portion of the object) and the background and the standard deviation of the noise parameter were quantified, and algorithms were developed using MATLAB. Results: The CNR information was greatly influenced by changing the image recreation calculations and was very much increased in the soft-tissue recreation images using 16-MDCT and 64-MDCT. The CNR information was also increased more in the optimum recreation images than in the reproduced images from the computational procedure used in the 80-MDCT. The results did not show any remarkable contrasts in the CNR values between the different object sizes. Overall, a higher kVp produced an improved CNR in all the CT scanners. In particular, there were prominent upgrades in the CNR information when the kVp was increased from 80 to 120. Higher mAs levels gave better CNR values overall, especially for greater section thicknesses. Based on the CNR estimations, the 64-MDCT provided the best correlation among the CT scanners. Conclusions: The objective LCD appraisal method, based on CNR measurements, was confirmed as being useful for checking the different impacts of kVp, mAs and section thickness on the nature of the picture. This procedure was similarly viable in assessing the impacts of the different reconstruction calculations and the different differentiation questions on the nature of the image.
6 November 2019 in Journal of Medical Radiation Sciences
Introduction: Digital radiography (DR) systems enable radiographers to reduce the radiation dose to patients while maintaining optimised image quality. However, concerns still exist about paediatric patients who may be exposed to an increased level of radiation dose which is not needed for clinical practice. The purpose of this study was to evaluate the knowledge, awareness and attitudes, in terms of image quality optimisation of radiographers undertaking paediatric DR in Australia and Saudi Arabia.Methods: A survey‐based study was devised and distributed to radiographers from Australia and Saudi Arabia. Questions focused on Australian and Saudi Arabian radiographers’ knowledge and attitude of paediatric DR examinations.Results: There were 376 participants who responded to the survey from both countries. A major finding showed that most participants lack knowledge in the area of paediatric DR examinations. Most participants from Australia had received no formal training in paediatric digital radiography (79%), whereas nearly half of the participants from Saudi Arabia received no training (45%). Approximately three out of four radiographers from both countries believed that when using DR they did not need to change the way they collimate the beam as DR images can be cropped using post‐processing methods.Conclusion: The finding of this study demonstrates that radiographers from both countries should improve their understanding and clinical use of DR in paediatric imaging. More education and training for both students and clinicians is needed to enhance radiographer performance in digital radiography and improve their clinical practices.
Computed tomography (CT) is a key imaging technique in diagnostic radiology, providing highly sensitive and specific information. While its use has increased dramatically in recent years, the quantity and associated risks of radiation from CT scans present major challenges, particularly in paediatrics. The fundamental principles of radiation protection require that radiation quantities be as low as reasonably achievable and CT use must be justified, particularly for paediatric patients. CT radiation knowledge is a key factor in optimising and minimising radiation risk. The objective of this study was to analyse knowledge level, expertise, and competency regarding CT radiation dose and its hazards in paediatrics among radiologists in Saudi Arabian hospitals. A self-reported, multiple-choice questionnaire assessed the attitudes and opinions of radiologists involved in imaging studies using ionising radiation. Among the total respondents, 65% ± 13.5% had a good comprehension of the dangers of carcinogenicity to the patient resulting from CT scans, with 80% presuming that cancer risks were elevated. However, only 48.5%, 56.5%, and 65% of the respondents were aware of specific radiation risks in head, chest, and abdominal paediatric examinations, respectively. Regular, frequent, and specific training courses are suggested to improve the fundamental knowledge of CT radiation among radiologists and other physicians.
1 January 2022 in International Journal of Dentistry
Medical ionizing radiation is widely used in hospitals, in particular dental clinics, and in medical research to facilitate the diagnosis and treatment of patients. The awareness, attitude, and perception of ionizing radiation exposure among dental undergraduate students and interns in radiological investigations and dental care clinics were investigated. A cross‐sectional study was conducted; 17 questions were designed online using the software “QuestionPro,” which was licensed to the University of Imam Abdulrahman Bin Faisal. Participants included senior medical dental students from Imam Abdulrahman Bin Faisal University in their third to fifth years, as well as interns from King Fahad University Hospital and private dental care clinics. A total of 855 participants viewed, 360 started the questionnaire, and 258 (72%) completed it online. Overall, knowledge was lacking; 32% of respondents incorrectly believed that magnetic resonance imaging and ultrasound used ionizing radiation, while 38% were unsure. Dental X‐rays were deemed harmful by 40% (n = 104) of respondents. According to 33% (n = 85) of participants, there is no radiation scatter during an X‐ray or CT scan, while 30% (n = 76) are unsure. Respondents (44%; n = 104) were unaware of the radiation dose from a chest radiograph and (45%; n = 116) overestimated the radiation dose. The effects of ionizing radiation on healthy tissue are known to more than half of the participants (54%). According to 39% of respondents, digital radiography exposes them to less radiation than traditional radiography. In terms of radiation protection and hazard, 46% said personal monitoring badges should be always worn and 58% (n = 150) said lead aprons should be used on a regular basis. 63% of the subjects had received radiation protection education, such as formal lectures, tutorials, or workshops, while 37% (n = 95) had not. 53% of the respondents were not aware of the international recommendations from the International Commission on Radiological Protection. When asked if they would follow radiation protection protocols if they opened a private dental clinical practice in the future, 50% (n = 129) said they would.
19 August 2022 in Journal of Multidisciplinary Healthcare
Background: Iterative reconstruction algorithm (IR) techniques were developed to maintain a lower radiation dose for patients as much as possible while achieving the required image quality and medical benefits. The main purpose of the current research was to assess the level and usage extent of IR techniques in computed tomographic (CT) scan exams. Also, the obligation of practitioners in several hospitals in Saudi Arabia to implement IR in CT exams was assessed. Material and Methodology: The recent research was based on two studies: data collection and a survey study. Data on the CT scan examinations were retrospectively collected from CT scanners. The survey was conducted using a questionnaire to evaluate radiographers’ and radiologists’ perceptions about IR and their practices with IR techniques. The statistical analysis results were performed to measure the usage strength level of IR methods. Results and Discussions: The IR strength level of 50% was selected for nearly 80% of different CT examinations and patients of different ages and weights. About 46% of the participants had not learned about IR methods during their college studies, and 54% had not received formal training in applying IR techniques. Only 32% of the participants had adequate experience with IR. Half of the participants were not involved in the updating process of the CT protocol. Conclusion: The results indicate that the majority of radiographer and radiologist at four different hospitals in Saudi Arabia have no explicit or understandable knowledge of selecting IR strength levels during the CT examination of patients. There is a need for more training in IR applications for both radiologists and radiographers. Training sessions were suggested to support radiographers and radiologists to efficiently utilize IR techniques to optimize image quality. Further studies are required to adjust CT exam protocols effectively to utilize the IR technique.