Purpose.: We evaluated the diagnostic accuracy of macular ganglion cell-inner plexiform layer (GCIPL) measurements using a high-definition optical coherence tomography (Cirrus HD-OCT) ganglion cell analysis algorithm for detecting early and moderate-to-severe glaucoma. Methods.: Totals of 119 normal subjects and 306 glaucoma patients (164 patients with early glaucoma and 142 with moderate-to-severe glaucoma) were enrolled from the Macular Ganglion Cell Imaging Study. Macular GCIPL, peripapillary retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured in each subject. Areas under the receiver operating characteristic curves (AUROCs) were calculated and compared. Based on the internal normative database, the sensitivity and specificity for detecting early and moderate-to-severe glaucoma were calculated. Results.: There was no statistically significant difference between the AUROCs for the best OCT parameters. For detecting early glaucoma, the sensitivity of the Cirrus GCIPL parameters ranged from 26.8% to 73.2% and that of the Cirrus RNFL parameters ranged from 6.1% to 61.6%. For the early glaucoma group, the best parameter from the GCIPL generally had a higher sensitivity than those of the RNFL and ONH parameters with comparable specificity (P < 0.05, McNemar's test). Conclusions.: There were no significant differences between the AUROCs for Cirrus GCIPL, RNFL, and ONH parameters, indicating that these maps have similar diagnostic potentials for glaucoma. The minimum GCIPL showed better glaucoma diagnostic performance than the other parameters at comparable specificities. However, other GCIPL parameters showed performances comparable to those of the RNFL parameters.
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm2, P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.
Background/aims This study aimed to investigate treatment patterns and medication adherence of glaucoma. It also identified key factors associated with non-adherence. Methods It was a cross-sectional, observational study. Patients who use eye-drops for ≤2 years were recruited at 15 eye clinics from March to November 2013. Data were collected through self-administered questionnaires and medical chart review. Medication adherence was evaluated using patients’ self-report on pill count and defined as patients’ administering drug for ≥80% of prescribed days. Medication adherence rate was calculated by dividing actual number of administration from total prescribed number of administration for 7 days. Patients whose self-reported prescription was different from total daily doses of physicians' prescription were considered as non-adherent. Results A total of 1050 patients included, and medication adherence rate was evaluated in 1046 patients whose verification of adherence was available. Of the total, 27.4% were non-adherent, and the medication adherence rates of the total, the adherent, and the non-adherent were 90.6±17.8%, 96.8±5.5% and 56.6±24.7%, respectively. The most commonly used medication was prostaglandin (PGA) alone and the second was combination of two-class (β-blocker and carbonic anhydrase inhibitor (CAI)) and three-class combination of PGA, β-blocker and CAI followed. In multivariate analysis, the risk of non-adherence was 1.466 times greater in males than in females (95% CI 1.106 to 1.943) and 1.328-fold greater as the daily number of administration was increased (95% CI 1.186 to 1.487). Conclusion Approximately, one-third of the patients were non-adherent, and males and increased daily number of administration were associated with non-adherence. It highlights that more systematic treatment strategies should be considered for better medication adherence, leading to effective glaucoma management.