According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.
20 April 2016 in IEEE Transactions on Nuclear Science
This paper presents measurement results of a method by which the shapes of the output signals derived from a front-end readout circuit can be made insensitive to the input detector capacitance, to a degree limited only by the accuracy with which one can make an amplifier with unity gain. A charge sensitive amplifier including the detector capacitance compensation technique was implemented in a standard 180-nm CMOS technology with a 3.3-V supply voltage. The results show that the technique can successfully mitigate the performance degradation that accompanies large detector capacitance derived from either large-area radiation sensors and/or high permittivity materials, such as nanocrystalline assemblies. In order to verify the feasibility of the technique, we measured alpha particle spectra on two different sized silicon detectors that have detector capacitances of 1.26 pF and 21.84 pF, derived from 2-mm- and 10-mm-diameter devices, respectively. A configuration for integrating the fabricated preamplifier with a detector is also described to exploit the technique for any other application or experiment.
14 September 2022 in IEEE Transactions on Instrumentation and Measurement
This article introduces a radiation-hardened-by-design (RHBD) cold junction compensation (CJC) circuit to compensate for the voltage variation at the cold junction of a thermocouple used in a nuclear power plant (NPP) to detect the reactor temperature. The key idea of the RHBD circuit is to cancel the error induced by radiation, subtracting two reference voltages. In this design, two conditions should be satisfied to realize the first-order cancellation. First, the two voltages should have similar changes according to temperature and radiation. Therefore, two identical voltage generators are used in the proposed circuit. Second, the two reference voltages might have different values. The proposed circuit was fabricated using general purpose 0.18- $\mu \text{m}$ complementary metal–oxide–semiconductor (CMOS) technology with a shallow trench isolation (STI) process. The RHBD CJC circuit showed a reference voltage of 275 mV at room temperature. The final output voltage variation was 5.2 mV under irradiation up to 2 Mrad, and the temperature coefficient (TC) was 2.9 ppm/°C in a range of 20 °–110 °C without additional trimming and annealing. The proposed circuit showed improvements of 60% and 90% for the radiation effect and temperature variation, respectively, compared with the conventional reference circuit. The active area and power consumption were 0.035 mm2 and 1.716 mW, respectively.
1 February 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment