Chao Liu

Dr. Chao Liu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2018 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
CLChao Liu
Chao Liu
XTXinshou Tian
Xinshou Tian
KCKai Chen
Kai Chen
YSYuanyuan Su
Yuanyuan Su
YLYan Li
Yan Li
With the increasing proportion of wind power installed capacity, the influences of transient characteristics of wind turbines generator on safety and stability of power grid is becoming more and more important. The rotor side of doubly fed induction generator (DFIG) is connected to the grid through a back‐to‐back inverter, and vector control based on phase‐locking synchronisation is used generally. Phase‐locked loop (PLL) drive internal potential phase changes to achieve synchronous operation with the grid. Therefore, PLL has great influence on transient characteristics of DFIG. A dynamic model of PLL is built in this study. Phase‐locking performance of PLL under voltage phase jump is studied by changing its parameters, and its impact mechanism on transient characteristics of DFIG is proposed. Simulation models are built with DIgSILENT/PowerFactory. The influence of parameters of PLL on phase‐locking performance of DFIG under voltage phase jump is simulated.

22 December 2025 in Processes
Verified
Journal Article
Open access
PDF file
SLShuzhen Li
Shuzhen Li
YJYingwei Jiang
Yingwei Jiang
JYJun Yi
Jun Yi
BMBo Miao
Bo Miao
CLChao Liu
Chao Liu
GZGuangxue Zhang
Guangxue Zhang
Under the national carbon peaking and carbon neutrality goals, electrical equipment plays a crucial role in energy production, transmission, and end-use systems, making the research on its lifecycle carbon emissions and mitigation strategies particularly significant. Based on the Life Cycle Assessment (LCA) framework, this review systematically examines carbon emission characteristics across raw material acquisition, manufacturing, transportation, usage, and end-of-life recycling stages of electrical equipment. The analysis indicates that the manufacturing and usage stages are generally the main contributors to total lifecycle emissions. Moreover, challenges such as incomplete carbon data, inconsistent boundary definitions, and insufficient recycling systems are highlighted. Correspondingly, this review summarizes key mitigation pathways, including low-carbon design and material optimization, low-carbon manufacturing processes, energy-efficient operation supported by intelligent monitoring, and enhanced recycling and remanufacturing practices. Finally, future perspectives are proposed, emphasizing the need to establish unified LCA databases, develop intelligent and data-driven carbon monitoring systems, and strengthen cross-sector collaboration to support the green and low-carbon transformation of electrical equipment industries.

13 February 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
YLYan Li
Yan Li
CLChao Liu
Chao Liu
XTXinshou Tian
Xinshou Tian
ZWZhibing Wang
Zhibing Wang
Wind farms integrated to an AC power system through a voltage source converter‐based high‐voltage direct current system (VSC‐HVDC) are viewed as islanded wind farms. The wind farm side converter of VSC‐HVDC maintains a constant frequency of the wind farm collection network and also controls its voltage. However, the transient responding time of VSC‐HVDC is very short, and its fault responding feature is at the millisecond (ms) level. As a result, under grid fault conditions, the VSC station could be overloaded and even operation could be quitted because of blocking if islanded wind farms fail to limit their power generation in time. This study proposes a fault ride through control method for VSC‐HVDC connected with islanded wind farms based on the forced short circuit of the AC‐side bus of the VSC station. When there is a fault in the VSC‐HVDC and the protection equipment is not able to cut off the excessive power at the ms level, the short‐circuit resistance installed on the AC side of the VSC station would be switched to make a forced short circuit. That would activate the low‐voltage ride through mode of islanded wind farms, and therefore reduce the power flowing into the VSC quickly. The HVDC fault and short circuit on the AC side would be cleared at the same time. The VSC‐HVDC system accomplishes fault ride through.

7 November 2024 in Processes
Verified
Journal Article
Open access
PDF file
HCHe Chang
He Chang
YXYing Xing
Ying Xing
BMBo Miao
Bo Miao
LLLi Li
Li Li
CLChao Liu
Chao Liu
YLYongqian Liu
Yongqian Liu
Electrochemical energy storage (EES) plays a crucial role in reducing the curtailed power from wind and solar PV power (WSP) generation and enhancing the decarbonization effects of power systems. However, research on quantifying the carbon emission reduction effects of EES methods in the engineering field is still insufficient, which constrains decision-makers from making intuitive assessments of the decarbonization effects of energy storage. Therefore, drawing on the principles of the clean development mechanism (CDM), this paper proposes a method for quantifying the carbon emission reductions of a standalone EES station. Firstly, based on the design principles of building marginal emission factor in the CDM, a method for calculating the BM weight of WSP is proposed. Secondly, three quantification methods for the carbon emission reductions of EES are presented based on the complexity of the calculations. Lastly, to analyze the impacts of different operational conditions and calculation methods on the carbon emission reduction of energy storage systems, a dispatch model is constructed for various operational scenarios. The results of the case study indicate that different calculation methods yield varying results in terms of the carbon emission reductions of energy storage systems, with the sharply value method yielding the smallest reduction and the output curve method yielding the largest reduction. Additionally, when considering the losses in the state of charge (SOC) of an energy storage system and reducing the overall output fluctuations of WSP-EES, the carbon emission reduction potential of the energy storage will decrease. This study establishes a theoretical basis for quantifying the carbon emission reductions of standalone electrochemical energy storage systems, aiding decision-makers in gaining a deeper understanding of the role of electrochemical energy storage in carbon reduction and operational value.

26 January 2024
Verified
Book Chapter
Open access
PDF file
WCWenjing Chen
Wenjing Chen
CLChao Liu
Chao Liu
WYWanshui Yu
Wanshui Yu
JWJie Wen
Jie Wen
LZLihua Zhou
Lihua Zhou
Credit risk assessment (CRA) is a hot topic in both academia and financial circles. Existing CRA methods can encompass both experience-based and data-driven approaches. The data-driven approaches are mainstream in recent years. Various data-driven CRA techniques are constructed with machine learning techneques. Since the non-default consumers are far more than the default consumers, CRA is typically a class imbalanced problem. Indeed, the misclassification of default consumers usually encounters heavier loss than the contrary case. An asymmetric loss-oriented cost sensitive learning model named CSLINEX-SVM is proposed by using the asymmetry of LINEX loss to assign more costs to the minority class. In credit risk assessment, the default consumers (majority class) deserve more penalty than the non-default consumers (majority class). Thus, we apply the Nesterov accelerated gradient algorithm to solve CSLINEX-SVM for credit risk assessment. The experiments verify the effectiveness of CSLINEX-SVM.

25 August 2026 in Processes
Verified
Journal Article
Open access
PDF file
BMBo Miao
Bo Miao
SLShuzhen Li
Shuzhen Li
RLRui Liu
Rui Liu
JYJun Yi
Jun Yi
QYQiujie Yuan
Qiujie Yuan
GZGuangxue Zhang
Guangxue Zhang
Smart energy meters are widely deployed electronic terminals. Under large-scale deployment and long-term operation, their life cycle carbon emissions can become significant. Based on the life cycle assessment (LCA) framework, this review critically examines the life cycle carbon-emission characteristics and mitigation pathways of smart energy meters. Particular attention is given to system boundaries, data requirements, stage-specific hotspots, and cross-stage trade-offs. Representative studies indicate that use-stage electricity can account for approximately 70.1–88.5% oflife cyclee GWP. However, the dominant stage varies with electricity mix, service life, product configuration, and assessment boundary. Accordingly, mitigation priorities should include reducing operating power and communication demand, lowering the embodied carbon of printed circuit boards (PCBs), printed circuit board assemblies (PCBAs), and key electronic components, extending reliable service life, and improving end-of-life recovery. This review also distinguishes direct meter-level emissions from indirect system-level benefits. Key future needs include standardized accounting rules, component-level carbon data, anlife cyclele-based mitigation assessment.